Report the configuration
ST
Typical output is:
CH 1, MD 2, IP 4, CS 0.100A, SE 75.0, DL 2.0us, PU 300.0us, RT 500.0us, FL 1
CH 2, MD 0, IP 2, CS 0.100A, SE 25.8, DL 1.000ms, PU 1.000ms, RT 0.0us, FL 0
CH 3, MD 0, IP 1, CS 0.100A, SE 50.0, DL 1.000ms, PU 1.000ms, RT 6.000ms, FL 4
CH 4, MD 1, IP 4, CS 0.100A, SE 100.0, DL 100.0us, PU 1.000ms, RT 0.0us, FL 5
Where the numeric values are:
CH
Channel number
MD
Mode: 0 = continuous, 1 = pulse, 2 = switched
IP
Trigger input: 1, 2, 3, 4
CS
Current rating of the light
SE
Brightness percentage setting
DL
Pulse delay
PU
Pulse width
RT
Retrigger delay
Enable Ethernet Messages
GTm
m
= 0 to disable Ethernet messages
= 1 to enable Ethernet messages
When Ethernet messages are enabled, any error reports are sent to the most recent UDP or TCP
address from which a command has been received. See appendix B.
Read any error messages
GR
If Ethernet messages are not enabled, the last error number can be read by this command. Any
error displayed on the unit is cleared, so if there was a lighting error, the PP420 will resume auto-
sensing on that channel.
The reply is of the form:
Err 45
Error 45 was the last error
Err 0
No error has occurred since the last GR command
Report the version of firmware running in the PP420
VR
This command returns the firmware version. For example:
PP420 (HW001) V002
Clear Settings
CL
Clears the output channel configuration. This excludes the Ethernet settings. For each channel, if
the AUTO_SENSE flag is set, then the flag and the current rating are preserved.
Set/Clear the Webpage Password
EY
EY asc1, asc2, asc3, asc4, asc5, asc6