![Garbin TZ FIBER 540E Скачать руководство пользователя страница 59](http://html1.mh-extra.com/html/garbin/tz-fiber-540e/tz-fiber-540e_operation-and-maintenance-manual_3442787059.webp)
59
TZ FIBER 540E / 630E / Conveyor-E
Via Leonardo da Vinci, 32/B
36034 Malo (VI) Italia
Operation and maintenance manual
Rev. 01/18-GB
5.2 ROUTINE MAINTENANCE
When carrying out maintenance work, lock the ma-
chine controls, remove the ignition key. Inform all
personnel in the operating area that the machine
is stationary for maintenance purposes. If neces-
sary, place warning signs (Fig. 11) around certain
points, in order to inform other people that the ma-
chine is stopped for maintenance.
Periodically, perform full-washing of the machine
and thoroughly clean all parts.
After each wash, it is necessary to lubricate all
parts subject to friction.
CAUTION
Annex 1 on page 102, shows the maintenance
register. All interventions must be registered.
5.2.1 AIR FILTER
Periodically clean the air filter. Intervention times
depend on the environment factor. The more the
environment in which it operates is dusty the more
time it takes to intervene.
For normal use it is advisable to clean the filter
7
5
2
1
3
8
9
10
6
4
Fig. 10 - Internal diesel engine KUBOTA V3307 CR TE4BEU
1) Fuse box. - 2) Radio control receiver unit. - 3) Cartridge air filter. - 4) Vacuum air discharge valve. - 5) Engine control
unit. - 6) Fuel electric pump. - 7) Battery. - 8) Fuel filter. - 9) Additional fuel filter. - 10) Manual fuel implementation
pump. - 11) Hydraulic system oil filter. - 12) Outlet available for LED headlights or any alarms. - 13) Snap springs.
11
12
13
Fig. 11 - Warning sign
DANGER
DO NOT OPERATE
MAINTENANCE MACHINE