17
WARNING: Fan baffle plates included in the
package should be used with the connections for
horizontal and vertical flue extensions.
Figure 11.
The appliance must be connected to a power supply
line with an efficient earth connection. The appliance
must be connected to 220 ~ 230 V single phase
power supply line with efficient earth connection
through (3-10 A). Automatic circuit breaker.
Garanterm Ravi Conventional Combi Boiler Installation and User’s Manual
ELECTRIC CONNECTION
12
Product
Total
Equivalent
Flue Lenght
(m)
Air Baffle
(mm)
Garanterm
Ravi
HM 24
5
Ø46
4
Ø44
3
Ø42
2
Ø40
Garanterm
Ravi
HM 28
5
Ø46
4
Ø44
3
Ø42
2
Ø40
Figure 11
Figure 10
L = m
ax
. 5 m
Figure 8
Figure 9
L1 + L2 = 3 m
Total equivalent = 5 m
L1 + L2 + L3 = 3 m
Total equivalent = 5 m
90° elbow = equal to 1 m flue length
45° elbow = equal to 0,5 m flue length
L1
L1
L2
L3
L2
L1
L1
L2
L3
L2