5.3.
Save bench positions (memory function)
Adjust the bench to the desired position, using the UP 1 and DOWN 1
buttons.
Press the M button 3 times to access memory mode. Then within approx.
5 seconds press one of the M1, M2 or M3 buttons to save the set position(s).
The control system acknowledges the memory save operation with an
acoustic beep.
5.4.
Returning to saved positions
Press the appropriate M1, M2 or M3 button and keep it depressed until the
desired position has been reached and the drives switch off.
6. Warnings and error messages
Warnings and error messages can be shown at the manual switch display.
These messages are generated by the control system and supply
information about malfunctions and their causes.
Code
Cause
Troubleshooting
E 106
Short circuit at the
manual switch port
The control system has detected a short
circuit at the manual switch port. Operation of
the control system will be blocked for approx.
10 seconds. Rectify the fault. After this the
control system must be reinitialised.
E 212
Short circuit at the
Hall sensor
The control system has detected a short
circuit at the Hall sensor or at one or more
drives. Operation of the control system will
be blocked for approx. 10 seconds. Rectify the
fault. After this the control system must be
reinitialised.
F 215
Short circuit at the
motor port
The control system has detected a short
circuit at the power supply or at one or more
drives. Operation of the control system will
be blocked for approx. 10 seconds. Rectify the
fault. After this the control system must be
reinitialised.