028
029
ZT-PTS
SERIES
ZT-PTS
SERIES
OSD Menu Setting
G. Pattern Set
8 Programmable patterns are available with 16 characters of title.
After set the data to the each pattern #1 ~ 8, 81 ~ 88+preset buttons are working
as pattern #1 ~ 8.
G-1. PATTERN SET - PATT NO.
Up to 8 Programmable user-defined patterns are available.
G-2. PATTERN SET - PATT TITLE.
To set PATTERN TITLE move Joystick left / right or use the pan keys.
Press ZOOM TELE button moves to the next character from the left / right
and ZOOM WIDE button moves to the next character from the right / left.
(Space displays when
□
appears.)
The pattern title is not displayed on the monitor, but only for the reference
of the user.
G-3. PATTERN SET - DATA FILL
To memorize a pattern, press FOCUS FAR button in order to start the process.
The progress is shown as % filled. Press FOCUS FAR button again in order to
escape.
G-4. PATTERN SET - SAVE
To save the memorized pattern data, move the joystick right or press the
pan right key when the cursor is on SAVE. Then the cursor moves to the PATT
NO.02 in order to prepare for the next pattern.
G-5. PATTERN SET - EXIT
To escape this page, move the joystick right or press the pan right key.
PATTERN SET
PATT NO
: 01
PATT TITLE
: PATTERN 01
□□□□□□□□
DATE FILL
: 100%
SAVE
EXIT
OSD Menu Setting
H. Alarm Set
4 Alarm inputs are available and each alarm is activating to presets, group tours
or patterns.
H-1. ALARM SET - ALARM NO.
Up to 4 alarms are selectable by using joystick right or pressing the pan right
key when the cursor is on ALARM NO.
H-2. ALARM SET - ALARM INPUT
Alarm inputs can be programmed as NC (Normally Close) or NO (Normally
Open).
The default setting is OFF.
H-3. ALARM SET - ALARM ACT
Active alarms can trigger modes such as presets, Group tours 1-8, and
Patterns 1-8.
Use the joystick or pan keys to select any preset number, Group tour No.
H-4. ALARM SET - AUX ACT
You can select one of BLK (No AUX triggering) / AUX1 (triggering AUX1) /
AUX2 (triggering AUX2) and default value is BLK.
If ALARM triggers AUX, AUX will be off after 5 seconds. If many ALARMs
trigger AUX port one by one, the last one will be off after 5 seconds.
H-5. ALARM SET - SAVE
After setting up the alarm features, to save the data move the joystick right
or press the pan right key when the cursor is on SAVE. After saving the data,
the cursor moves to Alarm NO.2 automatically to prepare for the next alarm.
H-6. ALARM SET - EXIT
To escape this page, move the joystick right or press the pan right key.
ALARM SET
ALARM NO
: 01
ALARM INPUT
: OFF
ALARM ACT
: 001
AUX ACT
: BLK
SAVE
EXIT
• Before activating Alarms, you must set ALARM ENABLE at DOME SET
ALARM ENABLE.