![Ganz ZN-L7000 Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/ganz/zn-l7000/zn-l7000_instruction-manual_561376018.webp)
18
ENG-
Video loss alarm:
select here the option
On
if the unit is to activate an alarm when the video
signal is interrupted.
Motion alarm:
select here the option
On
if the unit is to activate an alarm when the
motion alarm is triggered.
Alarm input:
select here the option
On
in order to activate the alarming by means of an
external alarm sensor. Otherwise select
Off
. In addition, it is also possible
to select if the alarm is to be activated by an
Active high
or
Active low
voltage level. Enter into the text field a designation for the alarm input
which will then be displayed onscreen if an alarm is activated.
Alarm settings
Ù
Alarm connections
Options are provided to specify the behaviour of the VCS devices in the event of an alarm.
Connect on alarm:
select
On
, to automatically establish a connection to one of the predefined
IP addresses in the event of an alarm. The addresses will be contacted in
turn once until a connection is established. Select
Assign IP to input
if
you want a predefined allocation of alarm input and remote IP address.
Thereby only one remote IP address will be contacted in case of an alarm
namely the first IP address with alarm input 1 being triggered, the second
with alarm input 2 and so on. Choosing the parameter
Follow input 1
a
connection to the first IP address is established when alarm input 1 is
triggered and holds only until there is a contact at alarm input 1. For
example the connection is established when a push-button connected to
alarm input 1 is operated and will be disconnected automatically when the
button is let off.
Live video receiver IP address:
you can enter the IP addresses of possible receivers.
Remote receiver password:
here you can enter the respective receiver password in case
the receiver is protected by one.
Live video auto-connect:
select here the option
On
if it is required to re-establish a
connection to the previously specified IP address after each
restart, e.g. after a connection breakdown or network
dropout. The addresses will be contacted in turn once until a
connection is established.