background image

EG-8

 B/W Fix terminal/Mode Selection terminal

This terminal can be used as a B/W Fix terminal and also as a Mode Selection 
terminal that enables the dynamic switching of OSD settings. The mode selection 
setting needs to be adjusted beforehand on the OSD setting screen. The picture 
mode can be fixed at B/W by shorting the two contacts on the B/W Fix terminal. 
Fixing the picture mode at B/W can prevent the picture from having a phenome-
non in which continuous switching occurs between the color mode and B/W mode 
under infrared illumination. The Mode Selection terminal allows switching between 
Profile 1/Profile 2 selected on the OSD screen.

B/W Fix terminal/Mode Selection terminal

Infrared illumination and connection

 When using infrared illumination, please make sure to adjust the focal point of the lens 

in color mode.

 If excessive infrared illumination causes the phenomenon above, set the picture mode 

at B/W using the BW Fix terminal.

 RS485 communication terminal (with communication function)

The RS485 communication function enables remote operation of the OSD function.
*  For initial settings of camera for RS485 communication, please see “RS485 

Menu” of the separate “OSD Operation Manual.”

RS485 communication terminal

  While connecting a shielded twisted pair cable to a 

terminal [B/W Fix terminal, Communication terminal 
(AWG 16-30)], peel off the cable by 5 mm from the 
end.

 Termination resistance switch (with communication function)

During the RS485 communication connection, turn on the termination resistance 
switch of the camera connected at the end of the cable, and turn off all other 
switches. Adjust the characteristic impedance of the cable used to the same level 
as that of the termination resistance (120 

Ω

).

Termination resistance switch

Approximately 5 mm

Содержание ZC-D5000NXA series

Страница 1: ...INSTRUCTION MANUAL WITH...

Страница 2: ...adjust the lens focus by edge enhancement focus level bar and screen view zoom up down The Color Bar Output function enables the checking and adjustment of cable signal levels and monitoring of the im...

Страница 3: ...whether the camera is operating or not This can damage the CCD Charge Coupled Device 2 Do not place the camera in the following locations 1 Locations subject to extremely high or low temperatures Oper...

Страница 4: ...peration Switch 2 Focus View angle adjustment lever 5 Video output connector for service monitor 7 Termination resistance switch with communication function 8 B W Fix terminal Mode Selection terminal...

Страница 5: ...iling or wall When running cables on the exterior surface of the ceiling or wall please drill holes in the ceiling or wall as directed in step 1 then refer to Running cables on the exterior surface of...

Страница 6: ...iameter Pass the cable through here Embedding in the ceiling or wall Be sure to use the adapter ring when embedding the unit in the ceiling or wall 1 Drilling holes in the ceiling or wall Use the temp...

Страница 7: ...pter ring Please use the self tapping screws included Do not use any other screws Connecting the cables 1 Connect the power cable While using 12 V DC connect the positive side to 12 V DC 12V DC connec...

Страница 8: ...st the focal point of the lens in color mode If excessive infrared illumination causes the phenomenon above set the picture mode at B W using the BW Fix terminal RS485 communication terminal with comm...

Страница 9: ...s so it faces the subject 350 Pan 350 Rotation 180 Tilt Indicates the top of the camera Using the camera in a near horizontal position will show the camera cover on screen Forcibly adjusting the camer...

Страница 10: ...ns passes through the center of the dome cover as shown in the right hand side figure Axis of the lens Setting the Menu Operation Switch To adjust settings in the OSD menu press and hold down the Menu...

Страница 11: ...0 04 lx Color 0 004 lx B W 0 15 lx Color 0 015 lx B W 0 04 lx Color 0 004 lx B W SENS UP ON x512 0 0003 lx Color 0 00003 lx B W 0 00008 lx Color 0 000008 lx B W 0 0003 lx Color 0 00003 lx B W 0 00008...

Страница 12: ...85 communication terminal 2P screw terminal block AWG16 30 models with communication function only Adjustment switch OSD switch Push button switch with 5 contact points in 4 directions and at a centra...

Отзывы: