GANZ ZNT8-BA1Fxx-T Thermal Network Camera
User Manual
Precautions
Issue V1.0 (2016-02-22)
25
Figure 5-2
Image setting interface
Table 5-1 describes the image setting parameters.
Table 5-1
Image setting parameter description
Parameter
Description
Configuration Method
Polarity
/LUT
The temperature field of a scenario detected
by the thermal imaging camera will be
mapped to the value range 0~255 by
algorithm processing. In the black/white
display mode, this range is converted into
tones of grayscale, for example, 0 indicates
fully black and 255 indicates fully white. By
this grayscale, the temperature field of the
scenario is converted into an image. Actually
displayed
images
vary
with
specific
polarity/LUT. The most frequently selected
modes are white hot (hot objects are brighter
than cold objects) or black hot (hot objects are
darker than cold objects). The difference
between these two modes is the reversal of
relationship
between
brightness
and
temperature. Other optional modes include
rainbow and ironbow.
[Configuration
method]
Select from the drop-
down list
[Default value]
White Hot