The Q.station has similar connections as the Q.gate-IP with the following additional
interfaces:
•
Gigabit Ethernet (vs. 10/100 in Q.gate)
•
EtherCAT slave port (RJ45)
•
USB/SATA combo port
•
Digital Inputs (single LEMO connector Part # EGG.1B.308.CLL)
Connection
PIN
+5V Out
1
Digital Input 1
2
Digital Input 2
3
Digital Input 3
4
Digital Input 4
5
Digital Input 5
6
Digital Input 6
7
GND
8
•
DVI port: Used to transmit the built-in HMI screen.
•
2 x additional UARTs: There are 4 x UARTs total on a single Q.station, 2 of which
connect directly to the measurement modules via the base (same method used
with the Q.gate). The other 2 x UARTs are located on the front of the Q.station in
the form of LEMO plug (part # EGG.00.302.CLL). The external connector is part
# FGG.00.302.CLAD30Z.
•
CAN port: Used to connect to H and L of the CAN interface. This connection
uses the same hardware as the UART and SYNC lines.