background image

13

5

ǀ

 MAINTENANCE

Always turn off the filter unit first and allow the hot surfaces to cool before performing any 

maintenance or inspection. We also recommend securing the unit against unexpected start-

up.

If  the  filter  unit  discharges  hazardous  substances,  always  use  appropriate  personal 

protective equipment according to the nature of the hazardous substance.

 OTHER 

MAINTENANCE

Emptying dust 

containers

Regularly check the fill level of the dust container used on your model of cyclone 

and,  if  full,  empty  the  container  into  the  place  designated  by  the  operator.  We 

recommend that you set the frequency of checking and emptying depending on

the conditions in which the filtration unit is operated.

MAINTENANCE OF 

ELECTRICAL PARTS

Periodically  or  according  to  the  operator's  internal  regulations

,  check  that  all 

connectors  are  inserted  and  that  the  screws  of  electrical  connections  and 

terminals are tightened

. Perform these checks with the filter unit switched off.

Regularly 

check  the  insulation  condition  of  all  cables  and  the  grounding 

condition

.  In  case  of  any  damage,  contact  the  electrical  maintenance  personnel 

immediately.

Check  the  electric  motor  of  the  fan 

according  to  the  instructions  of  their 

manufacturers, given in

in separate manuals. The manuals are included in the delivery of the filter unit.

Maintenance of the electrical parts of the equipment may only be carried out by persons who 

are properly trained and qualified.

REMOVAL

PORUCH

Reduced suction 

effect

In case of reduced suction effect at the source, inspect and check:
- system settings, especially the fan

- pipes; dirt in the form of rags, crumpled newspapers, etc. could have got stuck 

here.

FAILURE

POSSIBLE CAUSE

SOLUTION

Fan failure on start-up

Wrong fan wiring. Improper wiring.

Check  the  warm  electric  motor.  It  is 

necessary  to  check  the  electrical 

connection of the fan.

Unbalanced rotating components

Check

balance

of 

rotating components

(especially

rotor

fan).

The cyclone vibrates 

considerably

Adhesive

 bonding of  the 

seams at

fan rotor

Check

rotor

fan

and if necessary, 

remove any deposits.

Содержание CYGG-080

Страница 1: ...CYCLONE SEPARATOR Instructions for use...

Страница 2: ...Manual version v4 Date created 2023 11 08...

Страница 3: ...NTS 7 PROHIBITED ACTIVITIES 7 safety instructions for operation and maintenance 8 RESIDUAL RISKS 8 4 INSTALLATION AND COMMISSIONING 10 WORKING ENVIRONMENT 10 OPERATING SPACE 10 AVAILABILITY 10 placeme...

Страница 4: ...structions in this manual to ensure not only ease of use but also optimum use and longevity of the equipment Do not operate the equipment until you are thoroughly familiar with all the instructions pr...

Страница 5: ...ABOUT THE INSTRUCTION 1...

Страница 6: ...ht of the equipment supplied is indicated on the equipment s nameplate Lift the load with the lifting device and transport it to the designated unpacking or storage location The delivered equipment ma...

Страница 7: ...pecified above Furthermore it is forbidden to operate them with components other than those with which they were supplied Cyclone separators must not be operated in a different power range than that s...

Страница 8: ...mple model of a cyclone The supplied models consist of the same components differing only in size 1 Cyclone body cylindrical part 5 Input flange 2 Cyclone body conical part 6 Output flange 3 Expansion...

Страница 9: ...ed or removed The selection of a particular model of cyclone separator its features and equipment is a matter of commercial negotiation between the manufacturer and the operator and this manual does n...

Страница 10: ...6 TECHNICAL DATA EXIT CONCENTRATION The guaranteed dust removal rate is between 70 95 depending on the type of dust and the extraction conditions LABELS ON FACILITIES Production label...

Страница 11: ...ompany that implements cyclone in its technology or the operator must ensure the following must clearly define the scope of responsibilities and competencies of the personnel designated for installati...

Страница 12: ...the nature of the work to be performed such as flame resistant and dielectric work suits steel toed work boots gloves helmets safety glasses ear protectors and respirators depending on local condition...

Страница 13: ...they are risks that remain even when all preventive and protective measures have been considered and implemented HAZARD Electric shock during installation maintenance or servicing of electrical parts...

Страница 14: ...Explosion due to non compliance with the maximum temperature of filtered particulates in the case of explosive dusts or mixtures PROTECTION The model of the filter unit is designed for the environmen...

Страница 15: ...material according to the operator s internal regulations or legislation valid in the country of installation of the filter unit 2 Visually check if any parts of the unit have been damaged during tra...

Страница 16: ...parts conductively connected The unit shall be prevented from unexpected start up according to the applicable national standards of the country of operation and shall be equipped with a lockable shut...

Страница 17: ...with the filter unit switched off Regularly check the insulation condition of all cables and the grounding condition In case of any damage contact the electrical maintenance personnel immediately Che...

Страница 18: ...the filter outlet Dirt leaks through the seal Check the tightening of the fixing plates Residual drift value TZL is too high Low extraction power and poor air rotation inside the cyclone and thus low...

Страница 19: ...e to determine the lifetime of the cyclone in general However before disposing of the cyclone and its parts render them unusable When disposing of the unit parts the instructions of the manufacturers...

Страница 20: ...RRANTY COVERS hidden defects in the material demonstrable design defects Defects covered by the warranty must be reported in writing to the manufacturer s service department Special cases can only be...

Страница 21: ...ent handling by unprofessional intervention by connecting or reconnecting to the wrong type or voltage of electricity normal mechanical wear and tear etc Other warranty conditions can be agreed in the...

Страница 22: ...g the dust container P 1 X B2 Inspection of the inner part of the cyclone and removal of sediments 1 X B3 Checking the cyclone hopper flanges for leaks 1 X B4 Inspection and repair of corroded parts o...

Страница 23: ...15...

Страница 24: ...G G filtration CZ s r o Hrub nova 1903 9 664 51 lapanice Czech Republic...

Отзывы: