Establishing a KVM-over-IP™
connection for the first time
G&D’s
KVM-over-IP™
technology makes it possible to transmit signals between the
target module and the IP matrix switch using a Gigabit Ethernet (layer 3).
Only after the initial setup of the KVM-over-IP™ connection between the target
module and the IP matrix switch can the target module be used with the IP matrix
switch.
By default, the following settings of the
Transmission
interface are preselected:
Automatic initial setup
You can conveniently set up the
KVM-over-IP™ connection
via the web application of
the IP matrix switch (see section
Adding end devices
in the manual of the
web application
of the IP matrix switch
).
Manual initial setup via direct connection
If you want to perform the initial setup manually, you can do this via the Target
module's own web application.
NOTE:
The
Transmission
interface of the target module is used for signal transmis-
sion between the target module and the IP matrix switch.
The
Network
interface is used
exclusively
for communication with the virtual com-
puters.
IP address of the
Network
interface:
Obtain address via
DHCP
(Fallback: IP address:172.17.0.10)
global network settings:
Obtain settings via
DHCP
NOTE:
Manual configuration as described in the following section is
not
necessary
in this case.