INSTALLATION GUIDE · USER MANUAL
GAS HEATER SERIES
14
TROUBLESHOOTING
G&D Heaters are robust and easy to use. The number of poten�al failure modes has been minimized by
the simple design and few moving parts. If you no�ce any
of the following mechanical issues, contact
G&D Technical Support as soon as possible:
•
Excessive or unusual vibra�on
•
Abnormally low pump pressure or unusual noise from pump
CONTROLLER ERRORS
Occasionally you may see and error message displayed on controllers (See page
s
8
-
9). Below is a list of
errors you may encounter, as well as a recommended solu�on
.
Dwyer TSW-150
Symptom/Error code
Explana�on
Solu�on
Err
Memory reading error
Try cycling power to the heater
and reprogramming setpoint. If
problem persists, replace unit
ErP
Error of probe not shown on
screen
Check that probe is correctly
connected, and is not shorted
or open
AH1
Probe 1 maximum temperature
alarm
Ensure that heater is connected
to a
n
appropriate
thermal
load
.
Clean wye
-
strainer.
AL1
Probe 1 minimum temperature
alarm
Ensure that heater is connected
to an appropriate
thermal load
.
Check gas heater is func�oning
AH2
Probe 2 maximum temperature
alarm
Same as AH1
AL2
Probe 2 minimum temperature
alarm
Same as
AL1
ooo/- - -
Open probe/shorted probe
Verify thermocouples are not
shorted or open. Replace/reseat
damaged thermocouple(s).