background image

78

 · Target and user modules (DP-HR-U)

B

User modules

User module »DP-HR-U-CON«

With

 DP-HR-U-CON

 user modules, you can connect a console (

DisplayPort

 monitor, 

keyboard, mouse and audio devices) to a digital matrix switch of the 

ControlCenter-

Compact

ControlCenter-Digital

 or the 

DVICenter

 series.

At the installed console, matrix switch users can access a target module to operate 

the connected computer.

The data stream of the connected USB devices is transmitted to the active target 

module with up to 16 Mbit/s (

DVI-U-CPU

DP-U-CPU

DP-HR-U-CPU

 and 

VGA-U-CPU

 series 

only).

Package contents

1 × 

DP-HR-U-CON

 user module

1 × Power cable

1 × EasyStart flyer

1 × »Safety instructions« flyer

Required accessories

1 × Category 5e (or better) twisted pair cable to connect the user module to

 

the matrix switch

Содержание DP-HR-CON

Страница 1: ...A9200141 1 30 G D Target and User Modules Installation and Operation DP HR U variants EN...

Страница 2: ...eat Emptor G D will not provide warranty for devices that Are not used as intended Are repaired or modified by unauthorized personnel Show severe external damages that was not reported on the receipt...

Страница 3: ...s equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful inter ference to radio communications However ther...

Страница 4: ...ber MC2 UC 47 Target module DP HR U CPU DH 54 Target module DP HR U CPU DH UC 60 Target module DP HR U CPU Fiber DH 66 Target module DP HR U CPU Fiber DH UC 72 Chapter B User modules User module DP HR...

Страница 5: ...P HR U iv Chapter C Generic HID Enabling disabling the user module s Generic HID mode 175 Enabling disabling the target module s Generic HID mode 176 Chapter D Extender mode Opening the on screen disp...

Страница 6: ...t d branch de toutes les sources d alimentation D branchez toutes les fiches d alimentation et toutes les alimenta tions lectrique de l appareil Trennen Sie alle Spannungsversorgungen Stellen Sie vor...

Страница 7: ...source Only operate this device with an earthed voltage source Use exclusively the G D power pack Only operate this device with the power packs included in delivery or listed in this operating manual...

Страница 8: ...les It is not permitted to use fibre optic modules which do not meet the requirements of laser class 1 in accordance to EN 60825 1 2014 By using such modules the compli ance with regulations and advic...

Страница 9: ...data stream of the USB devices connected to the active user module DVI U CON DP U CON and DP HR U CON series only is transmitted to the computer with up to 16 Mbit s Package contents 1 Target module...

Страница 10: ...PS 2 cable to connect the computer s PS 2 keyboard interface to this interface Mouse Use the green plug of an optional Twin PS 2 cable to connect the computer s PS 2 mouse interface to this interface...

Страница 11: ...ple via the web application Off The external power pack is not properly connected LED Colour Status Meaning Left Yellow Off No user module accesses the target module On A user module accesses the targ...

Страница 12: ...2048 2048 60Hz 1920 1080 50 or 60 Hz 1440 576i 50 Hz 1440 480i 60 Hz Further standardised resolutions within the video bandwith possible Vertical frequency 24 Hz to 120 Hz Horizontal frequency 25 kHz...

Страница 13: ...socket Power input Max 600 mA Housing Material Anodised aluminium Dimensions W H D 105 26 164 mm Weight Approx 380 g Operating environment Temperature 5 C to 45 C Air humidity 20 to 80 non condensing...

Страница 14: ...the connected computer The data stream of the USB devices connected to the active user module DVI U CON DP U CON and DP HR U CON series only is transmitted to the computer with up to 16 Mbit s Packag...

Страница 15: ...puter s USB ports to this port Keyb Use the purple plug of an optional Twin PS 2 cable to connect the purple PS 2 socket keyboard to this port Mouse Use the green plug of an optional Twin PS 2 cable t...

Страница 16: ...rix switch Trans 2 Connect this interface to a Dynamic Port RJ45 of another matrix switch Power supply Power In Plug the power cable of the power pack in this interface Then connect the power cable to...

Страница 17: ...b application Off The external power pack is not properly connected LED Colour Status Meaning Left Yellow Off No user module accesses the target module On A user module accesses the target module Blin...

Страница 18: ...Hz 2048 2048 60Hz 1920 1080 50 or 60 Hz 1440 576i 50 Hz 1440 480i 60 Hz Further standardised resolutions within the video bandwith possible Vertical frequency 24 Hz to 120 Hz Horizontal frequency 25 k...

Страница 19: ...IN 4 socket Current consumption Max 600mA 12VDC Casing Material Anodised aluminium Dimensions W H D 105 26 164 mm Weight Approx 400 g Operating environment Temperature 5 C to 45 C Air humidity 20 to 8...

Страница 20: ...series only is transmitted to the computer with up to 16 Mbit s Package contents 1 Target module DP HR U CPU MC2 2 DisplayPort video cable DP Cable M M 2 1 USB device cable 2 Audio cable 1 Power pack...

Страница 21: ...omputer s Line In inter face to this interface USB K M Use the USB device cable to connect one of the computer s USB interfaces to this interface Keyb Use the purple plug of an optional Twin PS 2 cabl...

Страница 22: ...starts as soon as it is supplied with power During start up the channels are automatically grouped see below Automatic grouping of channels When operating the target module for the first time the mat...

Страница 23: ...xample via the web application Off The external power pack is not properly connected LED Colour Status Meaning Left Yellow Off No user module accesses the target module On A user module accesses the t...

Страница 24: ...60Hz 2048 2048 60Hz 1920 1080 50 or 60 Hz 1440 576i 50 Hz 1440 480i 60 Hz Further standardised resolutions within the video bandwith possible Vertical frequency 24 Hz to 120 Hz Horizontal frequency 2...

Страница 25: ...tor 1 Mini DIN 4 socket Power input Max 1 0 A Housing Material Anodised aluminium Dimensions W H D 105 46 164 mm Weight Approx 570 g Operating environment Temperature 5 C to 45 C Air humidity 20 to 80...

Страница 26: ...nected to the active user module DVI U CON DP U CON and DP HR U CON series only is transmitted to the computer with up to 16 Mbit s Package contents 1 Target module DP HR U CPU MC2 UC 2 DisplayPort vi...

Страница 27: ...pplied audio cables to connect the computer s Line Out interface to this interface Line Out Use one of the supplied audio cables to connect the computer s Line In inter face to this interface USB K M...

Страница 28: ...nect this interface to another Dynamic Port RJ45 of the sec ond matrix switch Power supply Power In Insert the power pack s connection cable to this interface Start up Connect the power cable to the p...

Страница 29: ...first time the matrix switch recognises the main channel and the target module s additional channel The channels are automat ically added to a channel group NOTE You can adjust any manually or automa...

Страница 30: ...example via the web application Off The external power pack is not properly connected LED Colour Status Meaning Left Yellow Off No user module accesses the target module On A user module accesses the...

Страница 31: ...60 60Hz 2048 2048 60Hz 1920 1080 50 or 60 Hz 1440 576i 50 Hz 1440 480i 60 Hz Further standardised resolutions within the video bandwith possible Vertical frequency 24 Hz to 120 Hz Horizontal frequency...

Страница 32: ...nector 1 Mini DIN 4 socket Power input Max 1 2 A Housing Material Anodised aluminium Dimensions W H D 105 46 164 mm Weight Approx 580 g Operating environment Temperature 5 C to 45 C Air humidity 20 to...

Страница 33: ...d to the computer with up to 16 Mbit s Package contents 1 Target module DP HR U CPU Fiber 1 DisplayPort video cable DP Cable M M 2 1 USB device cable 2 Audio cable 1 Power pack 12V 2A only with varian...

Страница 34: ...erface Line Out Use one of the supplied audio cables to connect the computer s Line In inter face to this interface USB K M Use the USB device cable to connect one of the computer s USB interfaces to...

Страница 35: ...ace Now connect the power cable to the power pack and a power socket IMPORTANT The devices use components with laser technology which comply with laser class 1 They meet the requirements in accordance...

Страница 36: ...r example via the web application Off The external power pack is not properly connected LED Colour Status Meaning Left Yellow Off No user module accesses the target module On A user module accesses th...

Страница 37: ...dwidth 25 to 300 MP s DisplayPort 4 Lanes HBR 2 7 Gbps Max resolution 2560 1600 60Hz 4096 2160 30Hz Examplary resolutions 4096 2160 24 25 or 30 Hz 3840 2160 24 25 or 30Hz 2048 2160 60Hz 2048 2048 60Hz...

Страница 38: ...ssion rate Max 16 Mbit s Power supply Type Portable power pack 12V 2A Connector 1 Mini DIN 4 socket Power input Max 600 mA 12 VDC Housing Material Anodised aluminium Dimensions W H D 105 26 164 mm Wei...

Страница 39: ...transmitted to the computer with up to 16 Mbit s Package contents 1 Target module DP HR U CPU Fiber UC 1 DisplayPort video cable DP Cable M M 2 1 USB device cable 2 Audio cable 1 Power pack 12V 2A on...

Страница 40: ...computer s PS 2 keyboard interface to this interface Mouse Use the green plug of an optional Twin PS 2 cable to connect the computer s PS 2 mouse interface to this interface Connection to the matrix...

Страница 41: ...ible optical fibre cable Connect the other end of the cable to the Rx interface of a Dynamic Port provided at the second matrix switch Trans 2 Rx Insert the LC plug of a compatible optical fibre cable...

Страница 42: ...for example via the web application Off The external power pack is not properly connected LED Colour Status Meaning Left Yellow Off No user module accesses the target module On A user module accesses...

Страница 43: ...deo bandwidth 25 to 300 MP s DisplayPort 4 Lanes HBR 2 7 Gbps Max resolution 2560 1600 60Hz 4096 2160 30Hz Examplary resolutions 4096 2160 24 25 or 30 Hz 3840 2160 24 25 or 30Hz 2048 2160 60Hz 2048 20...

Страница 44: ...ssion rate Max 16 Mbit s Power supply Type Portable power pack 12V 2A Connector 1 Mini DIN 4 socket Power input Max 600 mA 12 VDC Housing Material Anodised aluminium Dimensions W H D 105 26 164 mm Wei...

Страница 45: ...ly is transmitted to the computer with up to 16 Mbit s NOTE This target module can be connected to a compatible fiber port of ControlCenter Compact matrix switches or ControlCenter Digital matrix swit...

Страница 46: ...lay Port video output to this interface DP CPU 2 Use one of the supplied video cables to connect the computer s second Dis play Port video output to this interface Line In Use one of the supplied audi...

Страница 47: ...rface of another Dynamic Port provided at the matrix switch Trans Channel 2 Rx Insert the LC plug of a compatible optical fibre cable Connect the other end of the cable to the Tx interface of the same...

Страница 48: ...uring start up the channels are automatically grouped see below Automatic grouping of channels When operating the target module for the first time the matrix switch recognises the main channel and the...

Страница 49: ...r example via the web application Off The external power pack is not properly connected LED Colour Status Meaning Left Yellow Off No user module accesses the target module On A user module accesses th...

Страница 50: ...Video bandwidth 25 to 300 MP s DisplayPort 4 Lanes HBR 2 7 Gbps Max resolution 2560 1600 60Hz 4096 2160 30Hz Examplary resolutions 4096 2160 24 25 or 30 Hz 3840 2160 24 25 or 30Hz 2048 2160 60Hz 2048...

Страница 51: ...nsmission rate Max 16 Mbit s Power supply Type Portable power pack 12V 2A Connector 1 Mini DIN 4 socket Power input Max 1 1 A Housing Material Anodised aluminium Dimensions W H D 105 46 164 mm Weight...

Страница 52: ...CON series only is transmitted to the computer with up to 16 Mbit s NOTE This target module can be connected to a compatible fiber port of ControlCenter Compact matrix switches or ControlCenter Digita...

Страница 53: ...isplay Port video output to this interface DP CPU 2 Use one of the supplied video cables to connect the computer s second Dis play Port video output to this interface Line In Use one of the supplied a...

Страница 54: ...e Rx interface of another Dynamic Port provided at the first matrix switch Trans 1 Channel 2 Rx Insert the LC plug of a compatible optical fibre cable Connect the other end of the cable to the Tx inte...

Страница 55: ...a compatible optical fibre cable Connect the other end of the cable to the Tx interface of the same Dynamic Port provided at the second matrix switch Power supply Power In Insert the power pack s conn...

Страница 56: ...for example via the web application Off The external power pack is not properly connected LED Colour Status Meaning Left Yellow Off No user module accesses the target module On A user module accesses...

Страница 57: ...t Video bandwidth 25 to 300 MP s DisplayPort 4 Lanes HBR 2 7 Gbps Max resolution 2560 1600 60Hz 4096 2160 30Hz Examplary resolutions 4096 2160 24 25 or 30 Hz 3840 2160 24 25 or 30Hz 2048 2160 60Hz 204...

Страница 58: ...nsmission rate Max 16 Mbit s Power supply Type Portable power pack 12V 2A Connector 1 Mini DIN 4 socket Power input Max 1 2 A Housing Material Anodised aluminium Dimensions W H D 105 46 164 mm Weight...

Страница 59: ...er with up to 16 Mbit s Package contents 1 Target module DP HR U CPU DH 2 DisplayPort video cable DP Cable M M 2 1 USB device cable 2 Audio cable 1 Power pack 12V 2A only with variants incl PowerPack...

Страница 60: ...he supplied audio cables to connect the computer s Line Out interface to this interface Line Out Use one of the supplied audio cables to connect the computer s Line In inter face to this interface USB...

Страница 61: ...Power In Insert the power pack s connection cable to this interface Start up Connect the power cable to the power pack and a power socket The target module starts as soon as it is supplied with power...

Страница 62: ...ample via the web application Off The external power pack is not properly connected LED Colour Status Meaning Left Yellow Off No user module accesses the target module On A user module accesses the ta...

Страница 63: ...1600 60Hz 3840 2160 30Hz Ultra HD 4096 2160 30 Hz 4K 1920 1080 50 or 60 Hz 1440 576i 50 Hz 1440 480i 60 Hz Channel 2 1920 1200 60Hz 1280 1024 85Hz 1080p60 Full HD 640 480 60Hz Further VESA and CTA st...

Страница 64: ...sparent Transmission rate Max 16 Mbit s Power supply Type Portable power pack 12V 2A Connector 1 Mini DIN 4 socket Power input Max 600 mA Housing Material Anodised aluminium Dimensions W H D 105 26 16...

Страница 65: ...puter with up to 16 Mbit s Package contents 1 Target module DP HR U CPU DH UC 2 DisplayPort video cable DP Cable M M 2 1 USB device cable 2 Audio cable 1 Power pack 12V 2A only with variants incl Powe...

Страница 66: ...the supplied audio cables to connect the computer s Line Out interface to this interface Line Out Use one of the supplied audio cables to connect the computer s Line In inter face to this interface US...

Страница 67: ...s 2 Connect this interface to a Dynamic Port RJ45 of the second matrix switch Power supply Power In Insert the power pack s connection cable to this interface IMPORTANT Connect only one of the target...

Страница 68: ...e Ident LED to quickly identify the device has been activated for example via the web application Off The external power pack is not properly connected LED Colour Status Meaning Left Yellow Off No use...

Страница 69: ...560 1600 60Hz 3840 2160 30Hz Ultra HD 4096 2160 30 Hz 4K 1920 1080 50 or 60 Hz 1440 576i 50 Hz 1440 480i 60 Hz Channel 2 1920 1200 60Hz 1280 1024 85Hz 1080p60 Full HD 640 480 60Hz Further VESA and CTA...

Страница 70: ...mission type transparent Transmission rate Max 16 Mbit s Power supply Type Portable power pack 12V 2A Connector 1 Mini DIN 4 socket Power input Max 700 mA Housing Material Anodised aluminium Dimension...

Страница 71: ...ck 1 Power cable only with variants incl PowerPack 1 EasyStart flyer 1 Safety instructions flyer Required accessories 1 Compatible optical fibre cable to connect the target module to the matrix switch...

Страница 72: ...o this interface PS 2 Keyb Use an optional PS 2 cable to connect the computer s PS 2 keyboard interface to this interface Connection to the matrix switch NOTE Keyboard and mouse signals can be transmi...

Страница 73: ...nnect the power cable to the power pack and a power socket The target module starts as soon as it is supplied with power Status displays The Power LED on the back panel of the target module shows the...

Страница 74: ...ng video signal was not detected Flashing No voltage at PS 2 interface or USB bus Right Green Off The target module is turned off On A user module accesses the target module Blinking The connection to...

Страница 75: ...er 50 125 OM2 Max 400 Meter 50 125 OM3 DVI CPU Fiber UC S Max 5 000 Meter 9 125 OS1 DVI CPU Fiber UC S Max 10 000 Meter 9 125 OS1 Audio DisplayPort Digital Transmission type 2 channel LPCM stereo Reso...

Страница 76: ...I The device supports monitors with a DDC CI function The DDC information are transparently forwarded to the moni tor to support a maximum number of monitors However the support cannot be guaranteed f...

Страница 77: ...PowerPack 1 Power cable only with variants incl PowerPack 1 EasyStart flyer 1 Safety instructions flyer Required accessories 2 Compatible optical fibre cable to connect the target module to two differ...

Страница 78: ...nal PS 2 cable to connect the computer s PS 2 keyboard interface to this interface Connections to the matrix switches NOTE Keyboard and mouse signals can be transmitted to the computer using either th...

Страница 79: ...h Trans 2 Tx Insert the LC plug of a compatible optical fibre cable Connect the other end of the cable to the Rx interface of a Dynamic Port provided at the second matrix switch Trans 2 Rx Insert the...

Страница 80: ...or example via the web application Off The external power pack is not properly connected LED Colour Status Meaning Left Yellow Off No user module accesses the target module On A user module accesses t...

Страница 81: ...eter 50 125 OM2 Max 400 Meter 50 125 OM3 DVI CPU Fiber UC S Max 5 000 Meter 9 125 OS1 DVI CPU Fiber UC S Max 10 000 Meter 9 125 OS1 Audio DisplayPort Digital Transmission type 2 channel LPCM stereo Re...

Страница 82: ...monitors with a DDC CI function The DDC information are transparently forwarded to the moni tor to support a maximum number of monitors However the support cannot be guaranteed for all monitor models...

Страница 83: ...t the installed console matrix switch users can access a target module to operate the connected computer The data stream of the connected USB devices is transmitted to the active target module with up...

Страница 84: ...USB input device remains unaltered when transmitted to the active target module USB Devices Connect any USB devices to these interfaces The data stream of the connected USB device is transmitted to a...

Страница 85: ...f the matrix switch Power supply Main Power Connect the power cable to the power pack and a power outlet Red Power If required connect the power cable of the optional power pack to this interface This...

Страница 86: ...t be established Status Trans On The communication to the counterpart station is estab lished successfully Off The communication to the counterpart station could not be established System Flashing Sys...

Страница 87: ...user module Interface LED Status Meaning Transmission Yellow Off No data connection to the counterpart station Flashing Data connection to the counterpart station established Green Off No user is log...

Страница 88: ...5 or 30Hz 2048 2160 60Hz 2048 2048 60Hz 1920 1080 50 or 60 Hz 1440 576i 50 Hz 1440 480i 60 Hz Further standardised resolutions within the video bandwith possible Vertical frequency 24 Hz to 120 Hz Hor...

Страница 89: ...tional Type External power pack Connection 1 Mini DIN 4 socket Power In Current consumption 12VDC 2 2A Casing Material Anodised aluminium Dimensions W H D 210 44 210 mm Weight Approx 1 3 kg Operating...

Страница 90: ...the connected USB devices is transmitted to the active target module with up to 16 Mbit s DVI U CPU DP U CPU DP HR U CPU and VGA U CPU series only The buttons on the front panel of the user module or...

Страница 91: ...of the USB input device remains unaltered when transmitted to the active target module USB Devices Connect any USB devices to these interfaces The data stream of the connected USB device is transmitte...

Страница 92: ...er pack and a power outlet of a different power circuit Start up Start the user module by pressing the Main Power button of the power pack Switching The buttons on the front panel of the user module o...

Страница 93: ...nterpart station could not be established System Flashing System is ready for operation or firmware update is executed Off Internal error Console Video On Strong video signal at video input Off No sig...

Страница 94: ...module Interface LED Status Meaning Transmission Yellow Off No data connection to the counterpart station Flashing Data connection to the counterpart station established Green Off No user is logged in...

Страница 95: ...4 25 or 30Hz 2048 2160 60Hz 2048 2048 60Hz 1920 1080 50 or 60 Hz 1440 576i 50 Hz 1440 480i 60 Hz Further standardised resolutions within the video bandwith possible Vertical frequency 24 Hz to 120 Hz...

Страница 96: ...tional Type Portable power pack Connection 1 Mini DIN 4 socket Power In Power input 12VDC 2 3A Casing Material Anodised aluminium Dimensions W H D 210 44 210 mm Weight Approx 1 3 kg Operating environm...

Страница 97: ...ted to the active target module with up to 16 Mbit s DVI U CPU DP U CPU DP HR U CPU and VGA U CPU series only When using the console to access a target module DP HR CPU MC2 connected to a dual head co...

Страница 98: ...this mode data of the USB input device remains unaltered when transmitted to the active target module USB Devices Connect any USB devices to these interfaces The data stream of the connected USB devic...

Страница 99: ...tup Turn on the user module after its installation Use the Main Power power pack or a redundant power pack to establish the power supply Turn on the Main Power power pack Use an optional power pack to...

Страница 100: ...he matrix switch recognises the main channel and the user module s additional channel The channels are automati cally added to a channel group NOTE You can adjust adjsut any channel groups that were c...

Страница 101: ...ready for operation or firmware update is executed Off Internal error Console Video On Strong video signal at video input Off No signal at video input or the signal quality is too weak to be processed...

Страница 102: ...Meaning Transmission Yellow Off No data connection to the counterpart station Flashing Data connection to the counterpart station established Green Off No user is logged in at the user module On A use...

Страница 103: ...solutions 4096 2160 24 25 or 30 Hz 3840 2160 24 25 or 30Hz 2048 2160 60Hz 2048 2048 60Hz 1920 1080 50 or 60 Hz 1440 576i 50 Hz 1440 480i 60 Hz Further standardised resolutions within the video bandwit...

Страница 104: ...100 240 VAC 0 6 A 0 3 A Redundant power supply optional Type External power pack Connector 1 Mini DIN 4 socket Power input 12 VDC 2 6A Housing Material Anodised aluminium Dimensions W H D 270 44 210 m...

Страница 105: ...I U CPU DP U CPU DP HR U CPU and VGA U CPU series only When using the console to access a multi monitor computer with four graphics out puts the separate images of the graphics outputs are displayed o...

Страница 106: ...user modules DP HR U Package contents 1 User module DP HR U CON MC4 1 Power cable 1 EasyStart flyer 1 Safety instructions flyer Required accessories 4 Category 5e or better twisted pair cables to con...

Страница 107: ...en transmitted to the active target module USB Devices Connect any USB devices to these interfaces The data stream of the connected USB device is transmitted to a compatible target module with up to 1...

Страница 108: ...this interface to another Dynamic Port RJ45 of the matrix switch NOTE Use category 5e or better twisted pair cables to connect the devices ADVICE You can also connect the target module directly to a...

Страница 109: ...ower power pack Use an optional power pack to supply the Red Power socket with power Automatic channel grouping When operating the user module for the first time the matrix switch recognises the main...

Страница 110: ...tem is ready for operation or firmware update is executed Off Internal error Console Video On Strong video signal at video input Off No signal at video input or the signal quality is too weak to be pr...

Страница 111: ...ished successfully Off The communication to the counterpart station could not be established MC4 Video 4 On Strong video signal at fourth video input Off No signal at fourth video input or the signal...

Страница 112: ...module On A user is logged in at the user module p Interface LED Status Meaning Transmission Yellow Off No data connection to the counterpart station Flashing Data connection to the counterpart statio...

Страница 113: ...24 25 or 30Hz 2048 2160 60Hz 2048 2048 60Hz 1920 1080 50 or 60 Hz 1440 576i 50 Hz 1440 480i 60 Hz Further standardised resolutions within the video bandwith possible Vertical frequency 24 Hz to 120 H...

Страница 114: ...supply Type External power pack Connector 1 Mini DIN 4 Buchse Power input 12 VDC 3 5A Housing Material Anodised aluminium Dimensions W H D 435 44 210 mm Weight Approx 2 3 kg Operating environment Tem...

Страница 115: ...with up to 16 Mbit s DVI U CPU DP U CPU DP HR U CPU and VGA U CPU series only Package contents 1 DP HR U CON Fiber user module 1 Power cable 1 EasyStart flyer 1 Safety instructions flyer Required acce...

Страница 116: ...the USB input device remains unaltered when transmitted to the active target module USB Devices Connect any USB devices to these interfaces The data stream of the connected USB device is transmitted t...

Страница 117: ...e optional power pack to this interface This provides a redundant power supply Connect the power cable with the power pack and a power outlet of a different power circuit Start up Start the user modul...

Страница 118: ...d not be established Status Trans On The communication to the counterpart station is estab lished successfully Off The communication to the counterpart station could not be established System Flashing...

Страница 119: ...the user module Interface LED Status Meaning Transmission Yellow Off No data connection to the counterpart station Flashing Data connection to the counterpart station established Green Off No user is...

Страница 120: ...olour depth 24 bit Video bandwidth 25 to 300 MP s DisplayPort 4 Lanes HBR 2 7 Gbps Max resolution 2560 1600 60Hz 4096 2160 30Hz Examplary resolutions 4096 2160 24 25 or 30 Hz 3840 2160 24 25 or 30Hz 2...

Страница 121: ...Internal power pack Connection 1 IEC plug IEC 320 C14 Current consumption 100 240VAC 0 6A 0 3A Redundant power supply Type External power pack Connection 1 Mini DIN 4 socket Power In Current consumpti...

Страница 122: ...I U CPU DP U CPU DP HR U CPU and VGA U CPU series only The buttons on the front panel of the user module or configured key combinations select keys let users switch between the connected matrix switch...

Страница 123: ...Connect the PS 2 mouse of the local console Keyb Mouse Connect the USB keyboard and or the USB mouse of the local console Generic By default Keyb Mouse mode you can use this interface to connect anoth...

Страница 124: ...the first matrix switch Trans 2 Tx Insert the LC plug of a compatible optical fibre cable Connect the other end of the cable to the Rx interface of a Dynamic Port provided at the second matrix switch...

Страница 125: ...dule by pressing the Main Power button of the power pack Switching The buttons on the front panel of the user module or configured key combinations select keys let users switch between the connected m...

Страница 126: ...counterpart station could not be established System Flashing System is ready for operation or firmware update is executed Off Internal error Console Video On Strong video signal at video input Off No...

Страница 127: ...g the user module Interface LED Status Meaning Transmission Yellow Off No data connection to the counterpart station Flashing Data connection to the counterpart station established Green Off No user i...

Страница 128: ...a Colour depth 24 bit Video bandwidth 25 to 300 MP s DisplayPort 4 Lanes HBR 2 7 Gbps Max resolution 2560 1600 60Hz 4096 2160 30Hz Examplary resolutions 4096 2160 24 25 or 30 Hz 3840 2160 24 25 or 30H...

Страница 129: ...Type Internal power pack Connection 1 IEC plug IEC 320 C14 Power input 100 240VAC 0 6A 0 3A Redundant power supply optional Type Portable power pack Connection 1 Mini DIN 4 socket Power In Power inpu...

Страница 130: ...et module DP HR U CPU MC2 connected to a dual head computer the monitors display the separate images of the graphics out puts When accessing a target module with one graphics input only only the first...

Страница 131: ...eakers optional Keyb Connect the console s PS 2 keyboard Mouse Connect the console s PS 2 mouse Keyb Mouse Connect the console s USB keyboard and or USB mouse Generic By default Keyb Mouse mode you ca...

Страница 132: ...ion 1 Rx Insert the LC plug of a compatible optical fibre cable Connect the other end of the cable to the Tx interface of the same Dynamic Port provided at the matrix switch IMPORTANT With enabled Gen...

Страница 133: ...the user module after its installation Use the Main Power power pack or a redundant power pack to establish the power supply Turn on the Main Power power pack Use an optional power pack to supply the...

Страница 134: ...is ready for operation or firmware update is executed Off Internal error Console Video On Strong video signal at video input Off No signal at video input or the signal quality is too weak to be proce...

Страница 135: ...tus Meaning Transmission Yellow Off No data connection to the counterpart station Flashing Data connection to the counterpart station established Green Off No user is logged in at the user module On A...

Страница 136: ...P 1 1a Colour depth 24 bit Video bandwidth 25 to 300 MP s DisplayPort 4 Lanes HBR 2 7 Gbps Max resolution 2560 1600 60Hz 4096 2160 30Hz Examplary resolutions 4096 2160 24 25 or 30 Hz 3840 2160 24 25 o...

Страница 137: ...er supply Type Internal power pack Connector 1 IEC plug IEC 320 C14 Power input 100 240 VAC 0 7 A 0 3 A Redundant power supply Type External power pack Connector 1 Mini DIN 4 socket Power input 12 VDC...

Страница 138: ...he console moni tors When accessing the system with a target module with only one graphics input only the first monitor shows an image NOTE This user module can be connected to a compatible fiber port...

Страница 139: ...le speakers optional Keyb Connect the console PS 2 keyboard Mouse Connect the console PS 2 mouse Keyb Mouse Connect the console USB keyboard and or USB mouse Generic By default Keyb Mouse mode you can...

Страница 140: ...h enabled Generic HID mode it is not possible to operate the OSD with a keyboard connected to the Generic socket IMPORTANT The devices use components with laser technology which comply with laser clas...

Страница 141: ...erface of a Dynamic Port provided at the matrix switch Transmission 3 Rx Insert the LC plug of a compatible optical fibre cable Connect the other end of the cable to the Tx interface of the same Dynam...

Страница 142: ...pack to supply the Red Power socket with power Automatic channel grouping When operating the user module for the first time the matrix switch recognises the main channel and the user module s addition...

Страница 143: ...is ready for operation or firmware update is executed Off Internal error Console Video On Strong video signal at video input Off No signal at video input or the signal quality is too weak to be proce...

Страница 144: ...Off No signal at second video input or the signal quality is too weak to be processed by the system Trans 4 On The communication to the counterpart station is established successfully Off The communi...

Страница 145: ...f No data connection to the counterpart station Flashing Data connection to the counterpart station established Green Off No user is logged in at the user module On A user is logged in at the user mod...

Страница 146: ...1 1a Colour depth 24 bit Video bandwidth 25 to 300 MP s DisplayPort 4 Lanes HBR 2 7 Gbps Max resolution 2560 1600 60Hz 4096 2160 30Hz Examplary resolutions 4096 2160 24 25 or 30 Hz 3840 2160 24 25 or...

Страница 147: ...er supply Type Internal power pack Connector 1 IEC plug IEC 320 C14 Power input 100 240 VAC 0 6 A 0 4 A Redundant power supply Type External power pack Connector 1 Mini DIN 4 Buchse Power input 12 VDC...

Страница 148: ...ter the monitors display the separate images of the graphics outputs When accessing a target module with one graphics input only only the first monitor dis plays an image Package contents 1 User modul...

Страница 149: ...ther USB input device In this mode data of the USB input device remains unaltered when transmitted to the active target module USB Devices Connect any USB devices to these interfaces The data stream o...

Страница 150: ...ser module with a second redundant power supply Startup Turn on the user module after its installation Use the Main Power power pack or a redundant power pack to establish the power supply Turn on the...

Страница 151: ...mmunication to the counterpart station is estab lished successfully Off The communication to the counterpart station could not be established System Flashing System is ready for operation or firmware...

Страница 152: ...ace LED Status Meaning Transmission Yellow Off No data connection to the counterpart station Flashing Data connection to the counterpart station established Green Off No user is logged in at the user...

Страница 153: ...Interfaces 1 RJ45 socket Transmission distance Max 140 metres Audio DisplayPort Digital Transmission type 2 channel LPCM stereo Resolutions 16 20 24 bit Sampling rates up to 48 kHz Audio Transmission...

Страница 154: ...ransparently forwarded to the monitor to support a maximum number of monitors However the support cannot be guaranteed for all monitor models USB Specification USB 2 0 Transmission type transparent Tr...

Страница 155: ...to a dual head com puter the monitors display the separate images of the graphics outputs When accessing a target module with one graphics input only only the first monitor dis plays an image Package...

Страница 156: ...n this mode data of the USB input device remains unaltered when transmitted to the active target module USB Devices Connect any USB devices to these interfaces The data stream of the connected USB dev...

Страница 157: ...outlet Red Power If required connect the power cable of the optional power pack to this interface This provides a redundant power supply Connect the power cable with the power pack and a power outlet...

Страница 158: ...buttons on the front panel of the user module or configured key combinations select keys let users switch between the connected matrix switches How to switch channels via buttons Press the button of t...

Страница 159: ...could not be established System Flashing System is ready for operation or firmware update is executed Off Internal error Console Video On Strong video signal at video input Off No signal at video inpu...

Страница 160: ...dule Interface LED Status Meaning Transmission Yellow Off No data connection to the counterpart station Flashing Data connection to the counterpart station established Green Off No user is logged in a...

Страница 161: ...tches Interface 2 RJ45 socket Transmission length Max 140 meters Audio DisplayPort Digital Transmission type 2 channel LPCM stereo Resolutions 16 20 24 bit Sampling rates up to 48 kHz Audio Transmissi...

Страница 162: ...forwarded to the moni tor to support a maximum number of monitors However the support cannot be guaranteed for all monitor models USB Specification USB 2 0 Transmission type transparent Transmission...

Страница 163: ...itor dis plays an image Package contents 1 User module DP HR U CON Fiber DH 1 Power cable 1 EasyStart flyer 1 Safety instructions flyer NOTE This user module can be connected to a compatible fiber por...

Страница 164: ...ets Enable the Generic HID mode see page 175 f if you want to connect another USB input device In this mode data of the USB input device remains unaltered when transmitted to the active target module...

Страница 165: ...vided at the matrix switch IMPORTANT The devices use components with laser technology which comply with laser class 1 They meet the requirements in accordance to EN 60825 1 2014 as well as U S CFR 104...

Страница 166: ...ack to provide the user module with a second redundant power supply Startup Turn on the user module after its installation Use the Main Power power pack or a redundant power pack to establish the powe...

Страница 167: ...communication to the counterpart station is estab lished successfully Off The communication to the counterpart station could not be established System Flashing System is ready for operation or firmwa...

Страница 168: ...an end device Right Green On A user module is accessing the target module Blinking No communication with the counterpart station Flashing Connection to the counterpart station established No user mod...

Страница 169: ...400 Meter 50 125 OM3 DVI CPU Fiber UC S Max 5 000 Meter 9 125 OS1 DVI CPU Fiber UC S Max 10 000 Meter 9 125 OS1 Audio DisplayPort Digital Transmission type 2 channel LPCM stereo Resolutions 16 20 24 b...

Страница 170: ...a DDC CI function The DDC information are transparently forwarded to the monitor to support a maximum number of monitors However the support cannot be guaranteed for all monitor models Main power sup...

Страница 171: ...s When accessing a target module with one graphics input only only the first monitor dis plays an image NOTE This user module can be connected to a compatible fiber port of ControlCenter Compact matri...

Страница 172: ...nect the console speakers optional Keyb Connect the console PS 2 keyboard Mouse Connect the console PS 2 mouse Keyb Mouse Connect the console USB keyboard and or USB mouse Generic By default Keyb Mous...

Страница 173: ...t the other end of the cable to the Rx interface of a Dynamic Port provided at the matrix switch IMPORTANT With enabled Generic HID mode it is not possible to operate the OSD with a keyboard connected...

Страница 174: ...atible optical fibre cable Connect the other end of the cable to the Tx interface of the same Dynamic Port provided at the matrix switch Power supply Main Power Connect the supplied power cable Insert...

Страница 175: ...key combinations select keys let users switch between the connected matrix switches How to switch channels via buttons Press the button of the desired channel to activate it How to switch channels via...

Страница 176: ...ng System is ready for operation or firmware update is executed Off Internal error Console Video On Strong video signal at video input Off No signal at video input or the signal quality is too weak to...

Страница 177: ...rechts gr n an Ein Arbeitsplatzmodul ist auf das Target Modul aufgeschaltet blinkt Kommunikation mit dem Matrixswitch nicht m glich blitzt Verbindung zum Matrixswitch erfolgreich aufgebaut Es ist kein...

Страница 178: ...x 400 Meter 50 125 OM3 DVI CPU Fiber UC S Max 5 000 Meter 9 125 OS1 DVI CPU Fiber UC S Max 10 000 Meter 9 125 OS1 Audio DisplayPort Digital Transmission type 2 channel LPCM stereo Resolutions 16 20 24...

Страница 179: ...a DDC CI function The DDC information are transparently forwarded to the moni tor to support a maximum number of monitors However the support cannot be guaranteed for all monitor models Main power sup...

Страница 180: ...b or a USB composite device containing multiple USB devices only the first of the connected HID devices can be used in Generic HID mode The OSD informs you if other HID devices of the composite device...

Страница 181: ...to the active target module How to select a USB keyboard mode 1 Press Ctrl Num default to open the on screen display 2 Press F11 to open the Configuration menu 3 Select Target and press Enter 4 Select...

Страница 182: ...Click OK to save your changes Multimedia PC keyboard with additional multimedia keys default Standard PC keyboard with standard keyboard layout Generic Any USB input device NOTE USB target modules add...

Страница 183: ...e you can change the user module settings in the module s OSD You can use the configured hotkey to open the on screen display at the console How to open the on screen display 1 Press Alt Num default t...

Страница 184: ...t hotkey modifier key and the Num hotkey can be changed How to change the hotkey to open the on screen display 1 Press the Alt Num default hotkey to open the on screen display 2 Select Hotkey and pres...

Страница 185: ...o open the OSD via double keypress 1 Press the Alt Num default hotkey to open the on screen display 2 Select Hotkey and press Enter 3 Select OSD via 2x keypress and press F8 repeatedly to select one o...

Страница 186: ...ut various technical features of the device The EDID profile of the monitor that is connected to the user module is not avail able at the target module Therefore the target module transmits a standard...

Страница 187: ...yboards The user module supports the additional keys of the follwoing PS 2 keyboards PixelPower Rapid Action PixelPower Clarity blue and SKIDATA1 How to activate the support of special PS 2 keyboards...

Страница 188: ...ngs 5 Restart the user module to apply your changes Reinitialising USB input devices After connecting a USB keyboard or mouse to the user module the input devices are initialised and can be used immed...

Страница 189: ...ays and tablets You can operate computers connected to the target module with one of the supported displays or tablets NOTE This setting has only an impact if a USB cable connects the target module to...

Страница 190: ...e target computer How to select a USB keyboard mode 1 Press the Alt Num default hotkey to open the on screen display 2 Select Keyboard Mouse and press Enter 3 Select USB HID mode and press F8 to selec...

Страница 191: ...t Keyboard Mouse and press Enter 3 Select IBM RS 6000 support and press F8 to select one of the following options 4 Press F2 to save your settings KEY COMBINATIONS SOLARIS SHORTCUT KEY OF SUN KEY BOAR...

Страница 192: ...functions and press Enter Resetting the default settings This setting resets the default settings of the extender mode All settings that have been changed by the user are reset How to reset the defau...

Страница 193: ...item see above 4 Press Enter to show the desired information 5 Press Esc to leave the menu FIRMWARE INFO This menu shows information about the user module console and the target module target ID Devic...

Страница 194: ......

Страница 195: ......

Страница 196: ...Drunck GmbH Systementwicklung Obere Leimbach 9 D 57074 Siegen Phone 49 271 23872 0 sales gdsys com www gdsys com US B ro US Office G D North America Inc 4001 W Alemada Avenue Suite 100 Burbank CA 915...

Отзывы: