G&D CAT-Repeater

A9100277-1.10

Installationsanleitung

DE

EN

Installation Guide

Содержание CAT

Страница 1: ...Guntermann Drunck GmbH www gdsys de G D CAT Repeater A9100277 1 10 Installationsanleitung DE EN Installation Guide...

Страница 2: ...D bernimmt keine Gew hrleistung f r Ger te die nicht bestimmungsgem eingesetzt wurden nicht autorisiert repariert oder modifiziert wurden schwere u ere Besch digungen aufweisen welche nicht bei Liefe...

Страница 3: ...or a Class A dig ital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful inter ference when the equipment is operated in a commercia...

Страница 4: ...6 Vorbereitung 6 Erweiterungsmodul installieren 7 Ein Arbeitsplatzmodul ber ein Erweiterungsmodul anschlie en 8 Vorbereitung 9 Erweiterungsmodul installieren 9 Power Loop Stromversorgung 10 Statusinfo...

Страница 5: ...Netzstecker des Ger ts vor Installationsarbeiten Stellen Sie vor Installationsarbeiten sicher dass das Ger t spannungsfrei ist Zie hen Sie den Netzstecker oder die Spannungsversorgung am Ger t ab St n...

Страница 6: ...n und die Kabel stecker stets mit einer Schutzkappe ab wenn diese nicht verbunden sind Ausschlie lich von G D zertifizierte bertragungsmodule verwenden Es ist nicht zul ssig Lichtwellen Module zu verw...

Страница 7: ...nnen Sie wahlweise zwischen zwei digitale Matrixswitches einem Rechnermodul z B DVI CPU und einem digitalen Matrixswitch einem Arbeitsplatzmodul z B DVI CON und einem digitalen Matrixswitch platziere...

Страница 8: ...n Slave Matrixswitch ber ein Erweiterungsmodul anschlie en Die folgende Skizze zeigt den Anschluss eines Slave Matrixswitches ber ein Erweite rungsmodul an den Master Matrixswitch ANZUSCHLIE ENDE KOMP...

Страница 9: ...PU Modus des Matrixswitches Verwenden Sie hierzu eine Twisted Pair Verkabelung der Kategorie 5 oder h her Transmission Fiber Verbinden Sie diese Schnittstelle mit einem Dynamic Port im CON Modus des S...

Страница 10: ...tallieren Sie den digitalen Matrixswitch 2 Installieren Sie das Target Modul das Sie ber die Erweiterung CAT Repeater an den Matrixswitch anschlie en m chten Der Anschluss des Target Moduls an den Mat...

Страница 11: ...ans Schnittstelle des Target Moduls Verwenden Sie eine Twisted Pair Verkabelung der Kategorie 5 oder h her Power In Schlie en Sie an diese Schnittstelle das Tischnetzteil oder das an ein anderes Erwei...

Страница 12: ...l anschlie en Die folgende Skizze zeigt den Anschluss eines Arbeitsplatzumoduls ber ein Erweite rungsmodul an den Matrixswitch CAT Repeater 7 3 5 1 6 8 4 2 Dynamic Ports Transmission Mouse Keyb DVI VG...

Страница 13: ...des Matrixswitches Verwenden Sie hierzu eine Twisted Pair Verkabelung der Kategorie 5 oder h her Transmission Fiber Verbinden Sie diese Schnittstelle mit der Transmission Schnittstelle des Arbeitspla...

Страница 14: ...Power Loop Kabeln mit Strom versorgt werden 1 Schlie en Sie das Tischnetzteil an eines der Erweiterungsmodule an 2 Stecken Sie ein Power Loop Kabel in die Schnittstelle Power Loop dieses Erweiterungsm...

Страница 15: ...gew hlt werden So installieren Sie den Ger tetreiber zur Adressierung der Service Buchse 1 ffnen Sie im Webbrowser des Computer die Website www gdsys de 2 Navigieren Sie in den Bereich Downloads Treib...

Страница 16: ...up Men dargestellt 4 W hlen Sie mit den Pfeiltasten die gew nschte Zeile des Setup Men s 5 Bet tigen Sie die Eingabetaste um die Informationen im Terminalemulationspro gramm anzuzeigen Die gew nschten...

Страница 17: ...angezeigt SFP Status Status SFT Vendor Hersteller SFP ID Typenbezeichnung CAT5 LINE INFO In diesem Men werden Informationen zur Twisted Pair Verbindung zur Komponente des digitalen Matrixswiitches ang...

Страница 18: ...n CAT gr n an Funktionierende Datenverbindung zur angeschlosse nen Komponente des digitalen Matrixswitches herge stellt aus Die Datenverbindung zur Gegenstelle ist unterbrochen Fiber Link Rx an Funkti...

Страница 19: ...ches Arbeitsplatzmodule und Rechnermodul Daten bertragung zwischen Modulen Schnittstelle 1 RJ45 Schnittstelle bertragungsl nge 140Meter Stromversorgung Typ Tischnetzteil oder Power Loop Anschluss Mini...

Страница 20: ...not provide warranty for devices that Are not used as intended Are repaired or modified by unauthorized personnel Show severe external damages that was not reported on the receipt of goods Have been d...

Страница 21: ...or a Class A dig ital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful inter ference when the equipment is operated in a commercia...

Страница 22: ...Installing the expansion module 7 Connecting a user module via expansion module 8 Preparation 8 Installing the expansion module for the matrix switch 9 Power supply via power loop cables 10 Displayin...

Страница 23: ...hnicians Disconnect the main power plug or the power supply before installation Before installation ensure that the device has been disconnected from the power source Disconnect the main power plug or...

Страница 24: ...l connections of the Transmission socket and the cable plugs with a connector or a protection cap Only use G D certified transmission modules It is not permitted to use fibre optic modules which do no...

Страница 25: ...lowing components between two matrix switches of the DVICenter series between a computer module DVI CPU and a matrix switch DVICenter between a user module DVI CON and a matrix switch DVICenter Packag...

Страница 26: ...Connecting a slave matrix switch via expansion module The following drawing shows how to connect a slave matrix switch to the master matrix switch using the expansion module COMPONENT TO BE CONNECTED...

Страница 27: ...5 or better twisted pair cable to connect this interface to a Dynamic Port in the CPU mode of the matrix switch Transmission Fiber Use a CAT5 or better twisted pair cable to connect this interface to...

Страница 28: ...1 Install the digital matrix switch 2 Install the target module you want to connect to the matrix switch using the CAT Repeater expansion Since the expansion module connects the target module to the m...

Страница 29: ...ed pair cable to connect this interface to the Trans interface of the target module Power In Connect the external power pack or the power loop cable which is connected to another expansion module to t...

Страница 30: ...matrix switch 2 Install the user module you want to connect to the matrix switch using the CAT Repeater expansion Since the expansion module connects the user module to the matrix switch at a later po...

Страница 31: ...ission Fiber Use a CAT5 or better twisted pair cable to connect this interface to the Transmission interface of the user module Power In Connect the external power pack or the power loop cable which i...

Страница 32: ...bles can be used to supply up to four other expan sion modules with power 1 Connect the external power pack to one of the expansion modules 2 Insert a Power Loop cable into the Power Loop interface of...

Страница 33: ...ted in the terminal emulator for establishing the connection How to install the device driver for addressing the Service socket 1 Open the website www gdsys de in your web browser 2 Go to Downloads Dr...

Страница 34: ...r 4 Use the arrow keys to go to the desired row of the setup menu 5 Press Enter to show the information in the terminal emulator The desired information see next page are shown in the setup menu If ne...

Страница 35: ...actor Pluggable module SFP Status Status SFT Vendor Vendor SFP ID Type designation CAT5 LINE INFO This menu shows information regarding the twisted pair connection to the matrix switch or the DVICente...

Страница 36: ...green on The data connection to the connected component of the digital matrix switch is established off Interrupted data connection to remote switch Fiber Link Rx on The data connection to the connect...

Страница 37: ...om puter module Daten transmission between modules Port 1 RJ45 port Transmission length 140metres Power supply Type external power pack or power loop Connection Mini DIN 4 socket Current consumption m...

Страница 38: ......

Страница 39: ...English...

Страница 40: ...re Leimbach 9 57074 Siegen Germany http www gdsys de sales gdsys de Das Handbuch wird fortlaufend aktualisiert und im Internet ver ffentlicht The manual is constantly updated and available on our webs...