Dead time control
Figure 6 - Dead time control circuit
Dead time is controlled by two RC delay circuits, R16/C15 and R22/C19. By default, 100ns dead time is
used. Additionally two potentiometers locations are provided (TR1/TR2, not included) to allow fine