Chapter 3: Unpacking and Installation 

 Complete Unit--Power-up test 

3 - 4 

 

The external power supply provided with the Stir/Purge is rated for operation from 100 to 240 V AC, at 
frequencies from 47 to 63 Hz. It should therefore be useable worldwide.   

The Stir/Purge external supply is supplied with a line cord suitable for use in the United States. In other 
countries, you may have to replace the line cord with one suitable for your electrical outlet type. You must 
always use a line cord with a CEE 22 Standard V female connector on the apparatus end of the cable. This is 
the same connector used on the US standard line cord supplied with your Stir/Purge. See Chapter 1 for specific 
safety information regarding line cord selection.  

The DC output cord from the external power supply plugs into the POWER IN jack on the rear panel of the 
Stir/Purge (see below): 

 

Power-up test 

Before you make any other connections to your Stir/Purge, power up the Stir/Purge and watch the blue POWER 
LED indicator on the front panel of the Stir/Purge: 

After connecting DC power to the Stir/Purge, turn on the POWER switch on the front panel of the Stir/Purge 
(see Figure 5 - 1). 

Watch the POWER LED as the Stir/Purge starts up. This LED should remain illuminated. The status of the other 
LED indicators is not important at this time. 

 

 

Caution: If the POWER LED goes on, then turns off and stays off, the 

Stir/Purge is not working properly! Contact Gamry Instruments or your local Gamry 
Instruments representative as soon as possible if this power-up test fails. 

To AC wall outlet (mains) 

To POWER IN 
connector on 
back of Stir-
Purge 

Insert line 
cord into 
power supply 

12 V DC input power 
from external supply 

Содержание VistaShield Stir/Purge

Страница 1: ...VistaShield Stir Purge Operator s Manual...

Страница 2: ......

Страница 3: ...l Free US Canada Only We will be happy to provide a reasonable level of free support for registered users Reasonable support includes telephone assistance covering the normal installation and use of t...

Страница 4: ...at any time without incurring any obligation to install same on systems previously purchased All system specifications are subject to change without notice There are no warranties which extend beyond...

Страница 5: ...wever Gamry Instruments Inc assumes no responsibility for errors that might appear Copyrights VistaShield Faraday Cage with Stir Purge Operator s Manual copyright 2017 Gamry Instruments Inc all rights...

Страница 6: ...iv...

Страница 7: ...Purge 2 1 Notational conventions 2 2 Chapter 3 Unpacking and Installation Complete Unit 3 1 Unpacking 3 2 Initial visual inspection 3 2 Physical location 3 2 VistaShield Stir Purge setup options 3 2...

Страница 8: ...ound 5 6 Appendix A Firmware Updates 6 1 Computer requirements 6 1 First time device installation in Windows 6 2 Appendix B CE Certificate 6 3 Declaration of Conformity 6 3 Certificate of Conformance...

Страница 9: ...ed in this standard it is a Category III apparatus designed for connection to low voltage circuits The AC Adapter supplied with the Stir Purge option is certified under EN 60950 The AC Adapter convert...

Страница 10: ...cal test This connection of the VistaShield to an earth ground is not a Protective Earth Ground as defined in IEC 1010 The VistaShield Stir Purge is safe in the absence of this connection since it doe...

Страница 11: ...ning Use a cloth lightly dampened with either clean water or water containing a mild detergent to clean the outside of the Stir Purge enclosure Alternatively you can use isopropyl alcohol Do not use a...

Страница 12: ...immunity from electrical transients including transients on the incoming AC mains supply and Electrostatic Discharge It has been tested for compliance with EN 61326 1998 Electrical equipment for meas...

Страница 13: ...e The European Community has instituted standards limiting radio frequency interference emitted by electronic devices setting limits for susceptibility of apparatus to RF energy and transient events a...

Страница 14: ...Chapter 1 Safety Considerations RoHS Compliance 1 6...

Страница 15: ...with materials used to make the Stir Purge Solenoids stainless steel for wetted parts Viton seals Needle valve nickel plated brass and Viton Connectors Brass or Ni plated Brass Viton Tubing High densi...

Страница 16: ...L remote control option Compatibility with Gamry software complete with customization Notational conventions In order to make this manual more readable we have adopted some notational conventions Thes...

Страница 17: ...mounted under the VistaShield Installation includes Inspection of the System Software Installation if required Connecting Power Connecting Digital Control Installing gas flow fittings The next chapte...

Страница 18: ...tir Purge for cable and gas tubing connections If you place your Stir Purge within an enclosed space make sure that the internal temperature within that space does not exceed the 45 C ambient temperat...

Страница 19: ...e screen as Autoplay runs a Setup program USB Port The USB port on the back of the Stir Purge is currently used for firmware updates only Do not make any connections to this port during normal install...

Страница 20: ...output cord from the external power supply plugs into the POWER IN jack on the rear panel of the Stir Purge see below Power up test Before you make any other connections to your Stir Purge power up th...

Страница 21: ...utlet ports if you desire The photograph of the rear panel above shows the normal installation of the fittings A quick disconnect fitting is used on the inlet port so the VistaShield and Stir Purge ca...

Страница 22: ...Chapter 3 Unpacking and Installation Complete Unit Gas fitting installation 3 6...

Страница 23: ...of 1 8 NPT to barbed end fitting 15 pin cable part 985 00118 Stir Purge Configuration Kit contains 8 screws Mounting the Stir Purge to the VistaShield Follow this step by step procedure to install th...

Страница 24: ...e Stir Purge as a stand alone system The Stir Purge can be used without the VistaShield as a stand alone system In this configuration four screws are used to block the holes in the top of the Stir Pur...

Страница 25: ...ervice it should be returned to Gamry separately Follow these step by step instructions to disassemble the system 1 Inside the VistaShield chamber remove the four screws holding the VistaShield to the...

Страница 26: ...Disassembly of the Stir Purge from the VistaShield 4 4...

Страница 27: ...e POWER LED is off one or more of the following conditions may apply The front panel power switch is off There is no DC 12 V supply connected to the rear panel DC POWER IN connector The external DC po...

Страница 28: ...3 55 9 556 14 2468 4 82 10 816 15 4806 5 120 The choice of stir bar depends on the cell design STIR SPEED is not controlled by the REMOTE connector The REMOTE can only control whether stirring is on...

Страница 29: ...r purge operation FLOW RATE Knob The FLOW RATE knob is located on the left side of the Stir Purge front panel The knob is connected directly to a needle valve Turning the knob in a counterclockwise di...

Страница 30: ...two out Each of these will be discussed in turn A picture of the Stir Purge rear panel is given below POWER IN jack The VistaShield Stir Purge derives power from 12 volts DC input through the POWER IN...

Страница 31: ...opriate settings for the GAS and STIR inputs For those not using a Gamry Potentiostat the diagram to the right shows connector pin outputs output and input voltage levels and full signal descriptions...

Страница 32: ...and Faraday Cage has the ground post inside the Faraday cage connected to the ground reference of the potentiostat If this ground reference is also an earth ground then the system will be earth groun...

Страница 33: ...B cable The USB port on the rear panel of the Stir Purge is a Type B connector as defined in Revision 1 1 and 2 0 of the USB specification Use a standard shielded Type A B cable to connect this port t...

Страница 34: ...he Windows Plug and Play Manager If you have your Gamry Instruments software CD or DVD insert it in your computer s CD or DVD drive select Install the software automatically radio button then click th...

Страница 35: ...report number R0295 000 from Ergonomics Inc for safety analysis and report number RSI 2772L from Radiation Sciences Inc for EMC test and analysis EMC Standards Title Class Criteria EN 61000 4 2 EMC E...

Страница 36: ...Certificate of Conformance 6 4 Certificate of Conformance...

Страница 37: ...hout notice Environmental Temperature 0 to 45 C Humidity 10 to 90 non condensing Mechanical Dimensions 35 x 35 x 8 cm 14 x 14 x 3 inches Weight 4 6 kg 10 lbs Main Power Input Voltage 11 13 VDC Input C...

Страница 38: ...Appendix C Specifications 6 6...

Страница 39: ...1 Help system 2 1 hose barb 3 5 I O connector 5 5 inspection 1 1 installation 3 1 leaks 1 4 operation 1 3 Power Connection 3 3 Power Cord 3 3 POWER IN 3 4 POWER LED 3 4 5 1 power line transient 1 4 PO...

Страница 40: ...734 Louis Drive Warminster PA 18974 Tel 215 682 9330 Fax 215 682 9331 www gamry com info gamry com...

Отзывы: