Reference 3000

 Potentiostat/Galvanostat/ZRA Quick-Start Guide

 

988-00008  

                                                Gamry Instruments, Inc.  © 2008 

 

 

 

 

Tip:

  Current packages are:  DC105, EIS300, PHE200, PV220, 

EN120, EFM140, CPT110, VFP600, ESA400, eChemBasic, 
eChemDC, and eChemAC. 

 

 

Tip:

  If you want to change the name of a potentiostat or enter  

Authorization Codes after setup, use the Properties window for the 
potentiostat.   

To edit the potentiostat’s properties: 

1) 

Open the Control Panel by selecting 

Start

 > 

Control Panel

2) 

Open the Device Manger window by:  

In Vista

System and 

Maintenance > System > Device Manager

 from the Task 

Window on the left.  

In Windows XP

:  

Start 

Control Panel

 >

 

System

.  Open the Device Manager window by clicking on the 

Device Manager

 button on the Hardware tab in the System 

Properties window.   

3) 

In the Device Manager window, expand the “Gamry Instruments 
Devices” list.   

4) 

Display a context menu by right-clicking on the current name of 
the potentiostat and selecting 

Properites

5) 

Click on the 

Device Settings

 tab. 

6) 

Edit the properties as needed. 

7) Click 

on 

OK

 to save the changes. 

Enter Authorization Codes During Setup 

The Device Settings window for each potentiostat contains a 
listbox showing Authorization Codes for every Gamry 
software package that has been authorized. 

You must enter an Authorization Code for a software package 
before you can use it to run experiments.  If you try to run an 
experiment with an unlicensed package, a message naming 
the Authorization Code you need will be displayed.  

To enter the Authorization Codes: 

1) 

Find the ten-digit Authorization Codes on the license 
shipped with the potentiostat. 

2) 

In the Device Settings window for the potentiostat, use 
the 

Add

 button to access the Authorization Code Entry 

window.  Enter the name of the Package and 
corresponding Authorization Code.  Press 

Ok.

  Repeat 

for each package included on your license. 

Authorization Codes are linked to a specific 
potentiostat’s serial number.  Be sure to enter the 
Authorization Codes that were shipped with the 
potentiostat named in the Device Settings window. 

3) 

When you have labeled the potentiostat and entered all 
Authorization Codes, click on 

Finish

.   

Calibration 

Launch Gamry Framework 

The process of installing the Gamry Framework software 
adds two new icons to the desktop: 

Gamry

 

Framework

 and 

My Gamry Data

 

Use the 

Gamry Framework

 icon to launch 

the Gamry Framework software and open 
the Framework main window. 

 

Use the 

My Gamry Data

 icon to access the 

default location for experiment data.  You 
can use the Framework 

Options

 menu to 

specify a different destination for experiment 
data files. 

Icons are not added for the software packages you installed.  
You will use the Gamry Framework user interface to run 
experiments with these software packages. 

You can also use the 

Start

 > 

Programs

 > 

Gamry 

Instruments

 path to open the Gamry Framework main 

window. 

Make Sure Potentiostat Is Recognized by 
Framework 

When you restarted the PC after installing the Gamry 
hardware and software, you confirmed that the operating 
system recognized the potentiostat and found the appropriate 
software drivers. 

Now confirm that the Gamry Framework software recognizes 
the potentiostat. 

Содержание Reference 3000

Страница 1: ...hen the first four tasks have been completed the Reference 3000 potentiostat is ready to use You can run experiments and gather data with your Gamry software packages Instructions for running experime...

Страница 2: ...current generation The Reference 3000 Reference 600 and Series G Potentiostats work with Gamry Version 5 software only The PCI4 300 and PCI4 750 Potentiostats and the FAS2 Femtostat work with either V...

Страница 3: ...you return the potentiostat to Gamry put the instrument in this container for shipment 2 If custom scripts standard scripts with modifications are already on this PC back up the scripts 3 If a previo...

Страница 4: ...Start Guide 4 Gamry Instruments Inc 2008 988 00008 Mouse Pad with Color Coding for Leads Cell Cable black with color coded clips on leads CD Universal Dummy Cell 4 Calibration Shield USB Cable Ground...

Страница 5: ...art the Installation Wizard The Wizard will step you through the installation process Most of the steps will be familiar they are common to many other software installation procedures The next subsect...

Страница 6: ...ftware that is not included in the other documentation 2 Leave the Gamry CD in the drive 3 Shut down Microsoft Windows Do not restart the computer yet Next you will install the potentiostat in this PC...

Страница 7: ...ostat Two cell cables is shipped with the potentiostat One end of the cable has multiple color coded cell leads ending in alligator clips The other end of the cables have a fifteen pin male or female...

Страница 8: ...drivers automatically select Yes After working through the wizard go to the next step 3 If the Reference Family of instruments was detected remove the Gamry CD from the drive or If you see a message t...

Страница 9: ...enter the Authorization Codes 1 Find the ten digit Authorization Codes on the license shipped with the potentiostat 2 In the Device Settings window for the potentiostat use the Add button to access th...

Страница 10: ...lit Calibration Preparation Before you can use a new potentiostat you must calibrate it using the Universal Dummy Cell 4 shipped with the potentiostat Recalibrate a potentiostat every six months or af...

Страница 11: ...see page 16 for grounding instructions Start Calibration When the potentiostat has been connected to the Universal Dummy Cell you are ready to start the calibration To start calibration 1 Click on OK...

Страница 12: ...n Results SN txt where SN is the serial number of the Reference 3000 The next time you select this potentiostat in the Potentiostat Calibration window the information in the calibration results file w...

Страница 13: ...the EIS300 test 1 Connect the clips on the cell cable to the appropriate posts on the EIS edge of the Universal Dummy Cell 4 For color codes see page 16 or wait until the script displays connection in...

Страница 14: ...not displayed automatically select Start Run In the Run window type D switchboard in the Open field and then click on OK Substitute the letter of your CD drive for D 3 Click on the Echem Analyst Setu...

Страница 15: ...med for the type of experiment For example when analyzing data gathered with Potentiostatic EIS the Impedance menu contains commands for functions specific to EIS300 experiments Similarly some tabs in...

Страница 16: ...ess the F2 Skip button Grounding The Reference 3000 is a floating ground instrument Its cell cable contains only a floating ground lead black clip There is a grounding lug on the rear of the Reference...

Отзывы: