Introduction 

13 

Chapter 2:

 

Introduction 

About this Manual  

This manual covers the installation, safety, and use of the Gamry Instruments IMX8 Multiplexer. 

This manual describes use of an IMX8 Multiplexer with Revision 7.9 (and later revisions) of the Gamry 
Framework software. It is equally useful when setting up a newly purchased instrument or modifying the setup 
of an older instrument for use with new software. 

You will find dry technical material such as specifications and connector pin-out diagrams in the Appendices. 

This manual does not discuss software installation or software operation in any detail. Software support for the 
IMX8 Multiplexer is described in the Gamry Framework’s Help system. 

All the Gamry Instruments’ applications running under the Gamry Framework control the IMX8 Multiplexer via 
an IMX object. See the Framework’s Help system for information concerning IMX objects and their functions. 

About the IMX8 Multiplexer 

The IMX8 Multiplexer was developed to increase the throughput of your electrochemical testing program. It 
allows one potentiostat/galvanostat/ZRA to drive up to eight electrochemical cells. Under the control of an 
external computer, the IMX8 connects one cell at a time to the potentiostat, which makes an electrochemical 
measurement on that cell. 

The IMX8 was specially designed for the needs of electrochemists. Extra features such as sense line and shield-
switching, and control of inactive cells separate the IMX8 – designed specifically for electrochemists – from 
other general-purpose switching devices. 

The IMX8 has been integrated into Gamry Instruments’ electrochemical applications relevant to the IMX8 that 
run under the Gamry Framework. It allows many of the DC Corrosion measurement applications to increase 
their throughput by testing multiple cells in a single test run. In this system a sophisticated Microsoft 
Windows

®

-program is used to control both the IMX8 and a Gamry Instruments potentiostat. 

However, the IMX8 is not restricted to use in corrosion testing or use with Gamry Instruments hardware or 
software. It was designed to work with other potentiostats , including those sourcing as much as 1.5 amperes of 
current. Refer to Gamry Instruments’ Echem Toolkit

TM

 for use with 3

rd

 part potentiostats. 

This chapter of the IMX8 Operator’s Manual provides an overview of the operation of the IMX8. It discusses 
the following topics: 

 

Operation overview 

 

Switching and inactive cell control 

The material in this chapter is only an overview. If you are using your IMX8 Multiplexer with Gamry 
Instruments software, this overview should give you sufficient understanding to make intelligent use of your 
IMX8. 

Operation Overview 

Figure 2-1 shows a “typical” electrochemical test system built around an IMX8 Multiplexer. Up to eight cells 
can be connected simultaneously to an IMX8. The label on the block marked as a potentiostat is slightly 
misleading. Most potentiostats can also be used as a galvanostat or as a ZRA (zero-resistance ammeter) in an 
IMX8 system. 

In the description of this figure, keywords are in bold type and are defined in the next section. 

Содержание IMX8

Страница 1: ...IMX8 Multiplexer Operator s Manual Copyright 2022 Gamry Instruments Inc Revision 1 0 July 14 2022 988 00087...

Страница 2: ......

Страница 3: ...gineering time on our part can be performed on a contract basis Contact us with your requirements Limited Warranty Gamry Instruments Inc warrants to the original user of this product that it shall be...

Страница 4: ...Copyrights IMX8 Multiplexer Operator s Manual copyright 2021 2022 Gamry Instruments Inc all rights reserved Gamry Framework copyright 1989 2022 Gamry Instruments Inc all rights reserved Interface 1010...

Страница 5: ...13 Keyword Definitions 15 Switching and Inactive Cell Control 15 Notational Conventions 17 Chapter 3 Installation 19 Initial Visual Inspection 19 Physical Location 19 Quick start Guide for System Inst...

Страница 6: ...ppendix B I O Connections for the IMX8 35 Cell Cable Connector 35 Normal Cell Cable Connections 36 Potentiostat Connector 37 Connecting the IMX8 to Third party Potentiostats 38 Appendix C Certificatio...

Страница 7: ...meet the requirements of EN 61010 Safety requirements for electrical equipment for measurement control and laboratory use The IMX8 Multiplexer circuitry is at voltages low enough to be considered safe...

Страница 8: ...ated from earth ground so isolation of the IMX8 Multiplexer and System Potentiostat from earth is not required In these cases connection of the System Potentiostat chassis to an earth ground may lower...

Страница 9: ...e cable This is the same connector used on the US standard line cord supplied with your IMX8 The wiring polarity of a properly wired connector is shown in Table 1 2 for both US line cords and European...

Страница 10: ...n stored for a long period of time under unfavorable conditions It has been dropped or subjected to severe transport stress It has been subjected to environmental stress corrosive atmosphere fire etc...

Страница 11: ...is regard the following steps may help If the problem is static electricity sparks are apparent when you touch the IMX8 Placing your IMX8 on a static control work surface may help Static control work...

Страница 12: ...cy interference from electronic devices and mandating several safety requirements Gamry Instruments Inc has modified its instruments including the IMX8 to comply with these standards The relevant CE r...

Страница 13: ...the IMX8 designed specifically for electrochemists from other general purpose switching devices The IMX8 has been integrated into Gamry Instruments electrochemical applications relevant to the IMX8 t...

Страница 14: ...o digitally control these potentiostats In the case of analog potentiostats analog signals from a D A and A D computer interface can be sent When a cell is connected to the system potentiostat cell le...

Страница 15: ...ol mode for inactive cells Local Potentiostat A simple low current potentiostat that maintains potential control on inactive cells Unlike the system potentiostat the local potentiostat is incapable of...

Страница 16: ...00 mA You can normally use the IMX8 with potentiostats rated at up to 100 V of output compliance and 1 5 A of output current To avoid transients Gamry s software always turns off the cell at the syste...

Страница 17: ...n S3 and it cannot measure current The cell can be potentiostated at a voltage that is set via the D A converter seen in Figure 2 2 This is a 16 bit converter operating at a resolution of 152 59 V per...

Страница 18: ...ted list The items in a bulleted list such as this one are grouped together because they represent similar items The order of items in the list is not critical File names and folders Inside paragraphs...

Страница 19: ...nd the shipping carrier immediately Save the shipping container for possible inspection by the carrier Physical Location Place your IMX8 Multiplexer on a flat workbench surface You need access to the...

Страница 20: ...ight individual cells to the IMX8 EIS performance with an IMX8 and a Reference 600 or 620 and Interface 1000 or 1010 is optimal when all the cell cables are 1 5 m cables All other cables may create er...

Страница 21: ...software flash drive or it can be installed via an Internet download The most up to date download can be found on www gamry com If you have inserted the Gamry DVD or flash drive into your computer and...

Страница 22: ...fore plugging in the USB You may also safely remove the USB cable without powering down the IMX8 Multiplexer and your computer Be aware however that this may have undesirable consequences if the syste...

Страница 23: ...mry Framework shows a Device Status Bar under its main menu see Figure 3 3 If you don t see the Device Status Bar when you run the Gamry Framework it has been disabled in the Framework Options menu Po...

Страница 24: ...irmware Though no IMX8 Multiplexer was used in this example its status indicator behaves in the same manner described above Gamry Instrument Manager Use Gamry s Instrument Manager GIM application make...

Страница 25: ...ipped with the latest version of all its firmware From time to time Gamry makes changes to the instrument s firmware code and a firmware update is required to make use of the new or improved code Ther...

Страница 26: ...all process starts automatically After the relevant firmware is updated a window appears confirming the process is complete and successful Click the OK button The instrument is now ready to be used Se...

Страница 27: ...e 3 In the main menu bar choose Options Instrument Manager The Gamry Instrument Manager window opens a Click the button under Pair with to open the selection window b Select the potentiostat you want...

Страница 28: ...plexer Configure and Test The Select Function window appears a Select Multiplexer Pair Click the OK button b The Select Multiplexer to Pair window opens Select a multiplexer Click the OK button c The...

Страница 29: ...st the Communications and Run Your Experiment 1 Be sure your host computer is on the multiplexer is on and your potentiostat is on 2 Run the Gamry Framework software 3 In the main menu bar choose Expe...

Страница 30: ...ht amber LEDs on the front of the multiplexer illuminate in sequence two times Listen for the simultaneous clicks of the relays b Select Set Channel Click the OK button A window appears which prompts...

Страница 31: ...tion 31 When a particular channel runs the Channel LED for that channel illuminates Table 3 1 Channel LEDs Status LED color Active channel Green Inactive channel Off Inactive mode of Local Potentiosta...

Страница 32: ......

Страница 33: ...voltage measured versus IMX8 chassis ground operating no damage Typ 12 24 V Counter Electrode voltage measured versus IMX8 chassis ground Typ 30 V Channel Isolation Current leakage to active channel...

Страница 34: ...ectable 100 120 220 240 V rms Allowed voltage variation all ranges Typ 10 Power worst case Typ 15 VA Environmental Operating Temperature Range 0 to 40 C Relative Humidity Max 90 non condensing Storage...

Страница 35: ...t cell connectors one for each channel are located on the IMX8 front panel see Figure B 1 Each cell connector is a 9 pin female D shaped connector The pin layout of all eight connectors is identical T...

Страница 36: ...counter lead s resistance 9 Counter Electrode CE Connected to the cell s counter electrode The cell current flows through this connection Normal Cell Cable Connections Normally you can use one of Gamr...

Страница 37: ...o both black cell leads You can add an alligator clip provided to each of the cell connections The alligator clips simply slide onto the banana plugs If you need to permanently change the terminations...

Страница 38: ...tiostats The cable required for connection to third party potentiostats varies with the potentiostat The following suggestions may help you in constructing the cable In many cases the easiest way to b...

Страница 39: ...llowing standards as defined in report number R 3542P 1 from Retlif Testing Laboratories for EMC testing and analysis and report number RET 17514 01 from Washington Laboratories Ltd for safety analysi...

Страница 40: ...Certifications 40 Certificate of Conformance...

Страница 41: ...dards as defined in report number R 3542P 1 from Retlif Testing Laboratories for EMC testing and analysis and report number RET 17514 01 from Washington Laboratories Ltd for safety analysis EMC Standa...

Страница 42: ......

Страница 43: ...work software 19 23 26 27 29 Gamry Framework 13 GIM 24 25 27 ground 17 35 36 38 grounding 9 Help system 13 inactive cell 14 15 16 inactive mode 15 16 17 inspection 7 19 Instrument Manager 24 25 27 int...

Отзывы: