background image

 

 

 

 
 

USER INSTRUCTIONS 
 

MINI

 

m u l t i p u r p o s e   t r o l l e y  
 

 

CLASS

 I 

Содержание AURION MINI

Страница 1: ...USER INSTRUCTIONS MINI multipurpose trolley CLASS I...

Страница 2: ...modify the technical functional specifications and characteristics of subsequent versions of this product at any time without warning Instructions for use are an integral part of the trolley and there...

Страница 3: ...IN 13 Exceptional trasportation IN 13 De commissioning and disposal IN 14 BODY BO 1 Body BO 2 Top surface BO 2 Waste bin with lid BO 2 Central locking system BO 3 Wheels braking system BO 4 CONTAINERS...

Страница 4: ...ND DEVICES Note According to the CE declaration of conformity supplied together with the trolley the manufacturer or his authorized representative in the Community declares and guarantees that this pr...

Страница 5: ...INFORMATION pag IN 2 CERTIFICATE OF GUARANTEE PLEASE FILL OUT AND SEND A PHOTOCOPY SENDER COMPANY NAME ADDRESS TOWN POSTCODE NATION DATE OF PURCHASE TYPE AURION MINI SERIAL NUMBER...

Страница 6: ...hase GAMMA reserve the right to refuse acknowledgement of the guarantee should these data have been removed or tampered with after purchasing 4 The following are not covered by guarantee 4 1 damages s...

Страница 7: ...les specialist medical equipment and clinical records depending on the accessories installed on it and on the maximum allowable loading weight of the various components according to the indications co...

Страница 8: ...ccessory that can or has actually been installed in order to integrate the BODY of MINI Cards are grouped in families of accessories containers supports and devices Who should read the manual The pres...

Страница 9: ...the same for all trolleys on which some accessories are then assembled by GAMMA or by yourself Standard components standard body As far as the description of standards components is concerned refer to...

Страница 10: ...ble it is necessary to replace it Materials were chosen on the basis of their reduced toxicity and flammability Considering the intended use of the trolley attention was paid also to the mutual compat...

Страница 11: ...cal risks all products carried by the trolley must be contained in special packages It is forbidden to pour liquids and the like into the containers supplied with the trolley Suspend use of MINI if an...

Страница 12: ...magnetic hazard interference with other devices Electrical accessories if present During design manufacture the possible influence of magnetic fields and electrical influence were taken into considera...

Страница 13: ...onent accessory If one of these labels is ruined or not readable it is necessary to replace it Following is an example We remind you that 1 kg corresponds to 2 204 lb Environmental conditions MINI mus...

Страница 14: ...it is necessary to check the package content Inside the package you will find The components of the standard model The accessories of your model Instructions for use of the trolley the present documen...

Страница 15: ...uarded room Maintenance If MINI is used according to the instructions given in this manual it does not require particular maintenance interventions apart from the ordinary cleaning operations made nec...

Страница 16: ...ey 3 Remove all components from the body described starting from pag BO 1 4 Remove all components and accessories from the trolley described starting from pag BO 1 5 Apply a cleaning product and clean...

Страница 17: ...legislation in force As far as the disposal of components supplied by third persons is concerned refer to the instructions supplied with them Proceed as follows 1 Clean the trolley thoroughly pag IN...

Страница 18: ...each MINI trolley is supplied with the following components 1 Body pag BO 1 2 Top surface pag BO 2 3 Central locking system pag BO 3 4 Wheels braking system pag BO 4 5 Waste bin with lid pag BO 2 TEC...

Страница 19: ...p surface only small objects b Waste bin with lid Function Use the waste bin to collect waste Usage 1 Before using the waste bin open its lid b and place a plastic bag c inside it 2 Lift the lid b wit...

Страница 20: ...rs cannot be locked Key lock Function Features Usage This locking system allows to lock drawers by means of its special key ATTENTION Remove the second key and keep it in a safe place When MINI is bei...

Страница 21: ...rder to avoid unexpected movements of the trolley MINI is equipped with two wheels with brakes Wheel diameter 125 mm MINI400D 100 mm Usage Removal Operate the brakes by pushing with your foot on the s...

Страница 22: ...l accessories devoted to contain medicines used disposable devices etc that can be assembled on MINI In this page there is an usage example for these accessories 1 Front drawers pag CO 2 2 Trays pag C...

Страница 23: ...YDUR polyurethane the drawers body of ABS Usage Open the drawer and put medicines or devices into it ATTENTION The opening and closing of front drawers is conditioned by the central locking system if...

Страница 24: ...disposable medicines or medical devices Features Trays are available in different heights and can be made of ABS or light acrylic Assembly Insert the tray into the special runners after checking that...

Страница 25: ...e The dispenser shall be used to store disposable medicines or medical devices It is forbidden to pour liquids and the like into the dispenser Features The dispenser is equipped with 11 swinging a con...

Страница 26: ...use accessories that are different from those supplied by GAMMA Function features Stainless steel shelves shall be used to contain small objects such as cotton or gloves They are supplied together wi...

Страница 27: ...o store disposable medicines or medical devices Features Basins are available in the following heights 90 mm and 45mm They are supplied together with their holding frame Assembly 1 Assemble the basin...

Страница 28: ...es devoted to supporting medicines and medical devices that can be carried by MINI 1 Telescopic I V pole pag SU 1 2 Holding frame pag SU 3 3 Holding bar pag SU 5 4 Basin holding frame pag SU 5 5 Tub h...

Страница 29: ...esponsibility for damages to things or people Function This accessory shall be used to carry a maximum of two I V bags or small accessories such as hospital masks Features Height 600 1000 mm Maximum a...

Страница 30: ...of the trolley see lay out on pag SU 1 It is forbidden to use accessories that are different from those supplied by GAMMA Failure to observe the prescriptions and the procedures described in this doc...

Страница 31: ...l position of poles shall be the following 3 Follow the assembly procedure of the basins pag CO 5 Removal Follow the procedure described for assembly in reverse order Maintenance Refer to what is repo...

Страница 32: ...gs or people Function The holding bar can support 25mm or 30mm standard clamps Features The bar is made of stainless steel and is available in the following dimensions 25 x 10 mm cod 0690 30 x 10 cod...

Страница 33: ...e to observe the prescriptions and the procedures described in this document absolves the manufacturer of any responsibility for damages to things or people Function Features This holding frame has th...

Страница 34: ...acturer of any responsibility for damages to things or people Function Features This support has the function of sustaining needle tubs either rectangular as shown in this picture or circular tubs The...

Страница 35: ...ith an anti sliding pad Dimensions 38x31 cm Usage ATTENTION Improper use of the rotating tray may cause damages to the defibrillator Make sure you do not exceed the maximum allowable loading weight of...