The installation of the appliance and the condenser unit may only be carried out by your local
service organisation team or a qualified installer. The type of condenser unit to be used is to
be determined in consultation with your local service organisation or a qualified installer.
Chapter 3 Split units
Fitting the waste pipe
• Install the cabinet following the
instructions.
• Connect the waste pipe to the drains.
• Ensure that the drain pipe slopes
down and is fitted lower than the
evaporator drip tray in the cabinet.
• Fit a siphon to prevent bad odours
coming into the cabinet.
• Pay attention that the siphon does
not obstruct the flow too much.
• Fit separate waste pipes for drip
tray and rinsing bowl .
• Always use T-connectors 45º.
• Always connect the overflow to the
drains (in extreme circumstances it
may be possible that the evapora-
tion capacity is not sufficient).