background image

  Who have compromised local circulation or neurologic impairment (including 

paralysis or localized compromise due to multiple surgical procedures) in the 

affected region. 

  Who have rheumatoid arthritis in the affected region. 

  Who have a known and uncontrolled peptic ulcer since wraps confining and/or 

cooling the abdomen can cause increased gastrointestinal motility and gastric acid 

secretion.

CAutioNs 

  To avoid the risk of electrical shock, do not remove any panels from the Control Unit. 

Opening the case will void the Game Ready warranty. For all servicing and repair, in the 

U.S. call Game Ready Customer Service at 1.888.426.3732 (+1.510.868.2100); from 

outside of the U.S. please contact your local distributor.  

  To avoid the risk of electrical shock, always turn off the System and disconnect the 

power line cord from its electrical outlet when not in use or before adding or emptying 

ice and water. 

  Do not use any AC adapter other than that provided by Game Ready. Use of other 

adapters may result in electrical shock and will void the Game Ready warranty.

  To avoid damage to your product, do not operate the System without any water in the 

ice box. 

  To avoid electrical shock, product malfunction or damage, never operate the System with 

damaged power cords or Connector Hoses, or other mechanical damage, or if the unit is 

otherwise not fully operational. 

  To avoid potential damage to your product, do not pour hot water into the ice box. The 

System is not designed to operate, and has not been tested, with hot water. 

  To avoid damage to your product, do not pick up the Control Unit by the lid. Carry the 

Control Unit using the handle only. 

  To avoid potential damage to your product, do not use other manufacturers’ wraps with 

the Game Ready System. 

  To avoid damage to your product, do not operate the Control Unit without a Connector 

Hose attached.  

  To avoid injury, be careful not to trip over the System’s power cords and Connector Hose. 

  The GRPro Control Unit is a technical medical device. To avoid damage to your product, 

handle it with the same care as you would a laptop computer

. Do not drop it, kick it or 

otherwise abuse it unnecessarily. Such abuse will void all Game Ready warranties. Do not 

place the AC Adapter or battery pack inside the ice box for storage or transport.

s P e C i f i C A t i o N s

Size: 16.25” length x 7.75” width x 9.25” height (413 x 197 x 235) mm, not including Carry Bag 

Weight: 7.3 lb. empty, approximately 18 lb. full of ice and water 

Pressure level: cycles from 5mm Hg up to 75mm Hg 

AC power: 100-240 V~, 50-60 Hz, 1.6A 

DC input: 12V/2.5 A

Compression Therapy (vasopneumatic compression) using the Game Ready System or any 

compression therapy device should 

not

 be used in patients:

  Who are in the acute stages of inflammatory phlebitis in the affected region.  

  Who have any history or risk factors for deep vein thrombosis or pulmonary embolus 

(including prolonged bed rest) in the affected region (to be treated with this therapy). 

  Who have significant arteriosclerosis or other vascular ischemic disease in the affected region.  

  Who have a condition in which increased venous or lymphatic return is not desired in the 

affected extremity (e.g., carcinoma). 

  Who have decompensated hypertonia in the affected region.  

Cryotherapy using the Game Ready System or any cryotherapy device should not be used 

in patients: 

  Who have significant vascular impairment in the affected region (e.g., from prior 

frostbite, diabetes, arteriosclerosis or ischemia). 

  Who have acute paroxysmal cold hemoglobinuria or cryoglobulinemia.

C o N t r A i N d i C A t i o N s

G e N e r A l   W A r N i N G s   A N d   C A u t i o N s

WArNiNGs 

  Improper placement or prolonged use of the Game Ready System could result in tissue 

damage. 

  During the course of therapy, patients should monitor the skin surrounding the treated 

region or the digits of the extremities of the treated limb for any burning, itching, 

increased swelling, or pain. If any of these signs present, or any changes in skin 

appearance occur (such as blisters, increased redness, discoloration, or other noticeable 

skin changes), patients are advised to discontinue use and consult a physician. 

  Game Ready Wraps are not sterile; do not place directly against open wounds, sores, 

rashes, infections, or stitches. The Wrap may be applied over clothing or dressing. 

  Game Ready Wraps are available in multiple configurations but are not intended for  

all possible physiologic uses. For example, the Ankle Wrap is not designed for use on 

the toes and the Back Wrap is not designed for use in the abdominal region. 

  Compression Therapy (vasopneumatic compression) with the Game Ready System 

should be used only under the supervision of a licensed healthcare practitioner in 

patients: 

  Who have an open wound in the affected region (the wound must be dressed prior 

to use of Game Ready).

  Who have an acute, unstable (untreated) fracture in the affected region. 

  Who are children under 18 years old or patients who have cognitive disabilities or 

communication barriers, whether temporary (due to medication) or permanent. 

  Who have a cardiac insufficiency or congestive heart failure (with associated 

edema in the extremities or lungs). 

  Who have a localized skin condition (e.g., dermatitis, vein ligation, gangrene, skin 

graft) in the affected region. 

  Who have erysipelas or other active infection in the affected region.

  Cryotherapy with the Game Ready System should be used only under the supervision of 

a licensed healthcare practitioner in patients: 

  Who have Raynaud’s disease or cold hypersensitivity (cold uticaria). 

  Who have hypertension or extreme low blood pressure.

  Who have diabetes. 

EN-13

EN-12

SUPERSEDED

Содержание GRPro 2.1

Страница 1: ...odel Numbers 550550 03 550550 03 RN 550550 53 GRPro 2 1 Control Unit User s Manual53 Game Ready Control Unit User s Manual PN 703758 Rev D 2011 CoolSystems Inc All rights reserved Brought to you by Co...

Страница 2: ...of Operation______________________________________ 2 Buttons_________________________________________________ 2 Adjusting Temperature___________________________________ 3 Display______________________...

Страница 3: ...n on Programs Play Pause Use this button to start or pause a treatment Add Time Use this button to add time in Manual Mode does not work in Program Mode You can add up to 90 minutes Treatment must be...

Страница 4: ...a table during use Note that using the System in an environment with a high ambient temperature may affect its ability to provide adequate cooling or may limit the ice life If you will be using the S...

Страница 5: ...Make sure you hear it click To disconnect simply press the blue or gray button and remove the connector from the Wrap 9 Set your target temperature displayed in the Target Temperature window by turnin...

Страница 6: ...id your warranty Abrasive materials to clean the Control Unit Doing so will damage the plastics and will void your warranty Caution The Control Unit is not a waterproof device Do not apply a direct st...

Страница 7: ...tomer Service at 1 888 426 3732 1 510 868 2100 from outside of the U S please contact your local distributor 1 Identify the filter within the ice reservoir 2 Using two fingers grasp and squeeze the tw...

Страница 8: ...e in the acute stages of inflammatory phlebitis in the affected region Who have any history or risk factors for deep vein thrombosis or pulmonary embolus including prolonged bed rest in the affected r...

Страница 9: ...armful ingress of water 5 3 This product provides ordinary protection against ingress of water Degree of safety in the presence of flammable anesthetics or oxygen 5 5 Not suitable for use in an oxygen...

Страница 10: ...ufacturer s Declaration Electromagnetic Immunity The GRPro 2 1 is intended for use in the electromagnetic environment specified below The customer or the user of the GRPro 2 1 should assure that it is...

Страница 11: ...g NO Pressure wrap shall be vented to atmosphere The cooling temperature of the circulating ice water will be adjustable between 34 F 1 C and 50 F 10 C as long as the ice water in the ice box is suppl...

Страница 12: ...e connections Disconnect and reconnect Wrap from Connector Hose Make sure there is water in the ice box Verify that the ice box filter is not clogged Make sure there are no kinks in the Wrap or Connec...