GAME CHANGER AUDIO PLASMA Rack Скачать руководство пользователя страница 13

BACK PANEL

EFFECTS LOOPS

The PLASMA RACK offers three FX Loop Send and Return 

connections. Each FX Loop lets you insert an external effect at a 

different part of the PLASMA Rack’s signal chain:

FX Loop 1 will affect the DRY Signal only

FX Loop 2 will affect the WET Signal only, 

before it goes into the PLASMA Tube 

FX Loop 3 will affect the WET Signal only, 

after the PLASMA Tube.

12

GROUND LIFT

The ground lift switch disonnects the ground of all signal connectors from the AC Mains safety ground, 

allowing to break ground loops that may form between equipment connected to the signal chain. 

Use ground lift if 50/60Hz hum is heard together with audio signal. 

CAUTION - at least one of the devices in the signal chain has to be connected to AC Mains safety ground for safety purposes. 

Failing to do so may result in risk of electrical shock.

Содержание PLASMA Rack

Страница 1: ...MANUAL...

Страница 2: ...icians and engineers to break new ground PLASMA Rack is the result over 2 years of research and development dozens of prototypes and an incalculable amount of hard work We are all very happy with the...

Страница 3: ...GE AND BLEND EQUALIZER VOLUME AND UTILITY BUTTONS SUSTAIN OVERSATURATE AND CLEAN GATE TREMOLO BACK PANEL MIDI CONTROLS EXPRESSION PEDAL INPUT DEFAULT BUTTON STATES CLEAN DIRTY TOGGLE AND FACTORY RESET...

Страница 4: ...overdrive the PLASMA RACK uses a fly back coil transformer to express your instrument s live signal as a series of continuous high voltage discharges within a xenon filled tube In essence you are play...

Страница 5: ...onse Built In Distortion Channel A special button combination lets you add some High Class Op Amp dirt to your Dry signal 3 FX Loops with switchable level control Modify the signal path by inserting e...

Страница 6: ...es or multiple PLASMA Racks SUSTAIN turns on a compression circuit that prolongs the note s sustain in the PLASMA Tube OVERSATURATE creates overtones by overpowering the PLASMA Tube GAIN controls the...

Страница 7: ...IN MIDI OUT can be configured as OUT THROUGH see page 11 SEND 3 SEND 2 SEND 1 RETURN 3 RETURN 2 RETURN 1 MIDI THROUGH ON OFF turns the device ON and OFF GROUND LIFT BALANCED OUT LINE BALANCED IN comb...

Страница 8: ...e Mixing the DRY and WET signals lets you achieve more sound variations When BLEND is turned all the way to the left only the DRY audio can be heard in the output Gating EQ Tremolo set separately When...

Страница 9: ...n to a warm bass track When the CLEAN EQ button is switched ON both WET and DRY signals will be filtered VOLUME Master Volume Control affects the output levels of DRY and WET signals POWER The POWER B...

Страница 10: ...ality to melodic lines CLEAN GATE can also be used to eliminate Hum and noise from other pedals or effects in the signal chain Naturally the CLEAN GATE mode can be used when both DRY and WET signals a...

Страница 11: ...ar monics produced by the Flickering PLASMA Tube DYNAMIC DYNAMIC mode is a special kind of Tremolo effect specifically designed for the PLASMA Rack In essence DYNAMIC Mode makes the Tremolo Depth sens...

Страница 12: ...into the PLASMA Rack s MIDI OUT connector and the MIDI SEND button on the PLASMA Rack s front panel needs to be switched ON The MIDI OUT connector can also be configured as a MIDI OUT THROUGH for mor...

Страница 13: ...Loop 3 will affect the WET Signal only after the PLASMA Tube 12 GROUND LIFT The ground lift switch disonnects the ground of all signal connectors from the AC Mains safety ground allowing to break grou...

Страница 14: ...bination of knobs and buttons can be saved on one of PLASMA Rack s eight preset slots PRESET SLOTS 1 8 are indicated by 8 front panel buttons shown below To save a preset 1 Configure a Sound that you...

Страница 15: ...Reassigning the EXP Input 1 Make sure that the PLASMA Rack is ON 2 PRESS and HOLD the PAD Button until it starts blinking 3 While PAD is blinking turn the desired knob to the MINIMUM position 4 Then...

Страница 16: ...on 4 To Escape without saving PRESS the POWER Button NB Saving default button states will also save the CLEAN DIRTY Blend setting see next page Default Button States for Utility Settings The default s...

Страница 17: ...n an Overdriven signal 3 To return to CLEAN Blend repeat the SUSTAIN CLEAN GATE Long Press FACTORY RESET To return to the Factory settings and erase all saved presets follow these steps 1 Switch the d...

Страница 18: ...es performed by an Expression Pedal connected to RACK 1 will be repeated on RACK 2 ONLY if the MIDI SEND Button on RACK 1 is ON RACK 1 RACK 2 EXPRESSION PEDAL MIDI CONTROLLER M I D I O U T M I D I I N...

Страница 19: ...edance 220 Maximum output level 7 dBu Balanced output Connector Male XLR Pin 2 Hot Type Mic Line input RF ltered true bypass to balanced output Unbalanced output Connector Tip Sleeve Jack Impedance 22...

Страница 20: ...remolo Rate range 0 85 to 2600 Hz Depth control 0 100 in posi ve range or out nega ve range of phase between clean and distorted signals Tube Gas Xenon Discharge voltage 5 5 kV System performance Freq...

Страница 21: ...roved by Gamechanger Audio could void the User s authority to operate the equipment CA This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme...

Страница 22: ...ntrol DEPTH 24 0 1023 CC 24 CC 56 Tremolo depth control INPUT GAIN 21 0 1023 CC 21 CC 53 Drive gain control VOLTAGE 22 0 1023 CC 22 CC 54 Voltage gain control BLEND 23 0 1023 CC 23 CC 55 Blend between...

Страница 23: ...the apparatus has been damaged in any way such as by being dropped exposed to rain liquid being spilled on it or otherwise does not operate normally Service There are no user serviceable parts inside...

Страница 24: ......

Отзывы: