Galvo Shed GVO 3030 Скачать руководство пользователя страница 5

If you choose to vary from these instructions your warranty will be impaired

5

DIAGRAM 1

STEP 4 

BACK WALL

Join the 4 sheets 

C

 together with 2 fixings through the overlapping ribs, making 

sure the ends of the sheets are flush. Cap the sheeting with the 3000mm 
'U' channels 

F

.

Fix the channels through the end ribs and every second rib in between. Make sure 
you put at least one fixing per sheet up through the underside of the  channel into 
the pan of the sheet.

STEP 5 

ROOF

Join the sheets 

D

 together, same as the back. Cap the sheeting with the 3000mm 

'U' channels 

F

. Fix the channels at every second rib but not the corners at this stage. 

Place the short flange of the first 'L' flashing 

M

 on top of the rib at one end. 

Make sure the ends are flush with the sheeting (diagram 1) and put one  
fixing in the centre to hold the 'L' flashing. Fix the corners through  
the channels and one more between the corner and the centre  
fixing. Perform the same at the other end.
Fit the ridge beam 

R

 to 1 roof panel only. 

Fix through the ends and up through the  
internal flange on the underside.

GALVO TIP

Put extra fixings in for  

high wind areas, particularly  

on the underside.

YOU WILL NEED

8 x 1600mm x 780mm sheets 

4 x 3000mm 'U' channels

4 x 1600mm 'L' flashings

1 x 3000mm long ridge beam

D

F

M

R

YOU WILL NEED

4 x 1830mm x 780mm sheets 

2 x 3000mm 'U' channels with ends cut

C

F

F

F

C

R

M

M

F

F

D

Содержание GVO 3030

Страница 1: ...r or riveter Tape measure Ladder Non slip gloves good shoes and goggles A set of helping hands CALL 0508 454 873 for an installer near you Some parts have sharp edges and should be handled very carefu...

Страница 2: ...door sheets 2 x narrow 1830 x 715mm sheets beside door 4 x 1960mm angle cut sheets 2 x 2025mm gable cut sheets end walls 2 x 2290mm U channels for end walls top 4 x 1600mm L flashings roof to side fl...

Страница 3: ...ribs and the side U channels Attach the hinges P approx 150mm from the top and bottom of the door through the U channels The fixings should be centred on the side U channels Turn the door over and fi...

Страница 4: ...sheeting by 10 15mm on all panels PADLOCK KEEPER ASSEMBLY KEEPER WASHER RIVET P F F K K YOU WILL NEED 2 x 3000mm U channels with ends cut 2 x 1586mm door spacers 3 x padbolts F K P GALVO TIP To hinge...

Страница 5: ...ery second rib but not the corners at this stage Place the short flange of the first L flashing M on top of the rib at one end Make sure the ends are flush with the sheeting diagram 1 and put one fixi...

Страница 6: ...channels bottom 2 x 2290mm U channels top 2 x gable plates E H I R STEP 7 DOOR BRACES The door braces can be fitted now or after you have assembled your shed Tuck one end of the Z between the bottom...

Страница 7: ...l of the front and the back walls 10mm more than the overhang Fix beside every second rib You will not need to worry about these fixings leaking as any water seeping through these fixings will end up...

Страница 8: ...nt or act of God including weather b The warranty shall cease and the Supplier shall thereafter in no circumstances be liable under the terms of the warranty if the workmanship is repaired altered or...

Отзывы: