background image

 

Version 1, 18 December 2020, Page 

10

 of 

12

 

 

9.  Settings for pans. 

The default configuration for a pan is two 
buttons and one or two solenoids. By 

marking the ‘Link pans’ the outputs will 

work simultaneously.  

Chanel 1 is to be used for the half flush and 
the channel 2 for full flush. 

Set the required time and Hygiene flush for 

half flush (channel 1) and press ‘Upload’.

 

Similarly set the required time and Hygiene 
flush for full flush (channel 2) and press 

‘Upload’.

 

 

10.  Settings for shower. 

PB2 controller is capable of controlling two buttons 
and two showers (solenoids). 

Select channel to be changed. 

Select desired ‘Run time’.

 

Select desired ‘Lockout time’ if required or set to 
“0” if not.

 

Select ‘Shower end warning’. Recommended only if 

setting a lock out time. 

Press ‘Upload’ to store the settings in the 

controller. 

 

11.  Connection menu. 

By pressing the back arrow on Android 
device, the connection screen will pop up. 

The buttons allow to rename the 
controller, set new PIN, disconnect or go to 

setting screen ‘Next’.

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание Safe-Cell TZ-FLOWTPANMDT

Страница 1: ...utton inputs and up to 2 solenoids single solenoid only for flushing units Controller is pre programmed and ready to use The solenoids will open for a specific time once the appropriate button is pres...

Страница 2: ...quired to minimise ligature points and areas for concealment of contraband In addition to ensuring the products are fitted securely and in accordance with the following instructions consideration shal...

Страница 3: ...mend 300mm from the centre of the outlet and at a suitable height or to project specification Cut out details for face plate Faceplate to suit wall thickness between 30mm to 240mm Ensure the cut out d...

Страница 4: ...nyloc nuts and apply a thin bead of silicon on the edge of the wall cut out If extension leads are required please contact Galvin Engineering Do not force the faceplate to fit onto wall or attempt to...

Страница 5: ...ic nylon or electrical parts and seals and will void the warranty Note Controller must be mounted away from any moisture or potential water splashing 4 Mount control module Attach the control module t...

Страница 6: ...red please contact Galvin Specialised Do not cut the leads If the leads are too long it is recommended that any excess is coiled up and clipped to the wall 6 Connect power supply and check for correct...

Страница 7: ...scanning the first thing to come up in available devices will be a Mac address that looks like this example AB EC 69 57 34 02 This will eventually change to the name of the device which is from factor...

Страница 8: ...ory parameters will be downloaded to the app The Get log button will pop up the log data screen The Presets button will list all saved presets Drop Down menus First menu from left is to select the typ...

Страница 9: ...p down menu The PB2 controller can be used for showers basins and pans Depend of the feature selection setting slides will appear e g there is only Run time to be set for basin Run and Lockout times f...

Страница 10: ...nd Hygiene flush for full flush channel 2 and press Upload 10 Settings for shower PB2 controller is capable of controlling two buttons and two showers solenoids Select channel to be changed Select des...

Страница 11: ...ck electrical connections Replace solenoid valve Water or structural damage to electrical components Replace damaged electrical components Incorrect connections Check all connections Damage to sensor...

Страница 12: ...the only warranty given by the Galvin Engineering Pty Ltd With respect to the product Galvin Engineering Pty Ltd makes no other warranties express or implied Galvin Engineering Pty Ltd hereby specific...

Отзывы: