INSTALLATION

 

IMPORTANT: Galvin Specialised products must be installed in accordance with these installation instructions 
and in accordance with AS/NZS 3500, the PCA and your local regulatory requirements. Water and/or electrical 
supply  conditions  must  also  comply  to  the  applicable  national  and/or  state  standards.  Failing  to  comply  with 
these provisions shall void the product warranty and may affect the performance of the product. 

 

 

1. Fit body assembly 

  Secure body with mounting brackets as indicated, ensure 

it is protruding past the finished wall between 6mm 
minimum and 16mm maximum. 

  Brackets are suitable for horizontal and vertical mounting. 

  It is critical that the centre line of the cartridge spindle is 

perpendicular to the finished wall to ensure correct fitment 
of the faceplate and flange. 

2. Connect water supply 

  Connect water supply to correct inlets as 

shown, ensure a suitable sealing 
compound is used 

 

  Connect correct outlet connection to 

shower outlet.

 

 
Note: Water supply should be flushed before 
fitting. The use of in-line strainers is highly 
recommended. 

 

 

3. Fit faceplate & flange 

  Fit supplied o-ring into groove on the back of the flange. 

  Fit faceplate on to shoulder of flange. 

  Fit the switch (not supplied) to faceplate. 

4. Secure flange 

  Slide faceplate and flange onto the body. 

  Secure with three M4 cap screws and lock 

washers, ensure the faceplate anti-rotation 
pin to be pushed through the 

6.5mm 

hole.  

Содержание GalvinCare 50197

Страница 1: ...igned for wall installation IMPORTANT All GalvinCare prison taps are tested in accordance with AS NZS 3718 and leave our premises in good working order TECHNICAL DATA Inlet BSP Male Outlet BSP Female Headwork Diverter Cartridge Working Pressure Range kPa Min 50 Max 500 Working Temperature Range C Min 5 Max 90 Finish Chrome Polished Stainless Steel NOTE Galvin Specialised continually strive to impr...

Страница 2: ...le for horizontal and vertical mounting It is critical that the centre line of the cartridge spindle is perpendicular to the finished wall to ensure correct fitment of the faceplate and flange 2 Connect water supply Connect water supply to correct inlets as shown ensure a suitable sealing compound is used Connect correct outlet connection to shower outlet Note Water supply should be flushed before...

Страница 3: ...t so the body is perpendicular to finshed wall Water flow does not match faceplate markings Handle not aligned correctly to faceplate Remove handle and rotate on the spline until handle matches faceplate Re tighten Outlet on body not connected to the correct service outlet Change outlet connection on body SERVICE AND MAINTENANCE 1 Turn off water Turn off the water supply and turn on the tap handle...

Страница 4: ...r download from www galvinengineering com au Galvin Engineering Pty Ltd expressly warrants that the product is free from operational defects in workmanship and materials for the warranty period as shown on the schedule in the manufacturer s warranty During the warranty period Galvin Engineering will replace or repair any defective products manufactured by Galvin Engineering without charge so long ...