Galvin Specialised CliniLever Lead Safe TM-SHWX Скачать руководство пользователя страница 3

 
 

 

 

 

Version 3, 7 May 2020, Page 

3

 of 

4

 

Version 1, 7 May 2020, 3 of 4 

 

zVersion 1, 7 May 2020, 3 of 4 

 

Version 1, 7 May 2020, 3 of 4 

 

 
 
 

 
 

 

 

      

3.

  

Secure Mixer Body 

 

To allow proper fitment of the wall flange, 
allow a gap between 2mm & 7mm (as 
shown) between the finished wall and the 
rear of the main body.

 

 

Secure the mixer body using the mounting 
points.

 

 

4.  Fit Water Connections 

 

Ensure water supply lines are flushed before 
connecting. 

 

Fit the water connections as shown.

 

 

Ensure thread tape/sealant is used.

 

 

Note: This wall shower is not fitted with a flow 
restrictor. Never operate without a flow restrictor, as 
outlet will deliver full mains pressure with 
unrestricted flow. 

 
 
 
 
 
 
 
 
 
 
 
 

 

5.  Fit Handle & Flange 

 

Re-fit handle & flange ensuring care is taken 
to avoid scratching the mixer body.

 

 
 

6.  Secure Handle & Fit Indicator Button 

 

Using the supplied hex key, fit the grub screw 
as shown and secure the handle.

 

 

Fit the indicator button as shown.

 

 
 
 
 
 
 
 
 
 

 
7.  Test 

 

Once the shower mixer has been fitted, turn on mains water and check for leaks and correct 
operation.

 