background image

 
 
 
 
 
 
 
 
 
 

 
 

Version 1, 14

th

 April 2020, Page 

4

 of 

5

 

 

REMOVE & INSPECT FLOW REGULATING AERATOR

 

 
 
 
 

 
 
 

 
 
 
1.  Remove Flow Regulating Aerator Housing 

  Using the supplied tool (pictured) remove the 

flow regulating aerator housing as shown. 

  Ensure the flats on the outlet line up with the 

flats on the tool and turn anti-clockwise. 

 
 
2.  Remove & Inspect 

 

Remove the housing and flow regulating 
aerator. 

 

Inspect for debris and clean. Replace if 
necessary. 

  
 

 
 
 
  

3.

  

Reassemble 

 

Reverse steps 2 & 1 to reassemble ensuring correct orientation. 

 

Test for leaks and correct operation 

 

TROUBLESHOOTING 

PROBLEM 

CAUSE 

RECTIFICATION 

Tap is leaking 

Headworks are worn or 
damaged 

Remove and inspect the headworks, 
remove debris and/or replace parts if 
damaged 

Tap incorrectly installed 

Follow the installation steps above when 
fitting the tap. 

Tap has inconsistent flow 

Blocked flow regulating aerator 

Follow the instructions above to remove 
flow regulating aerator from the body and 
check for debris. Install an inline strainer 
to stop further blockages.  

Tap moves on basin 

Insufficiently tightened 

Follow the steps above in relation to 
tightening the installation. 

Water temperature is opposite to 
the handle markings 

Inlet hoses connected 
incorrectly 

Connect the inlet hoses to the correct 
inlets as shown above. 

Supplied Tool 

Flow Regulating 
Aerator 

Отзывы: