Galvin Engineering Ezy-Drink Lead Safe SS316 Скачать руководство пользователя страница 3

 

© Galvin Engineering Pty Ltd 

Product Installation Guidelines 

Version 4, 25

th

 October 2022, Page 

3

 of 5 

 

 

3. Tighten locknut and fit handle 

 

To resist theft/vandalism, ensure the 
stainless steel locknut is tightened firmly 
using an appropriate wrench.

 

4. Secure push button handle 

 

Lock push button handle in place by fitting grub 
screw and tightening using 2mm hex key. Take 
care not to overtighten.

 

 

 

5. Fit flexi-hose 

 

Fit flexi hose to outlet and body as shown. 

6. Testing

 

 

Once the drinking tap has been installed and tested 
for leaks, the water height must be adjusted to suit 
the available pressure.  

 

To adjust water flow 

1.  Remove the blanking screw 

2.  Adjust the water height by turning the regulator 

screw 

3.  Replace blanking screw. 

Note:  The full range from minimum flow to maximum 
flow is only ¼ turn.

 