background image

 

 

Version 1, 4 February 2020, Page 

3

 of 

4

 

        

 

3. Testing 

  Once the drinking tap has been installed and tested for leaks, the water height may be adjusted to suit 

the available pressure.  

  To adjust water flow 

1.  Remove the blanking screw 

 

2.  Adjust the water height by turning the regulator screw 

 

3.  Replace blanking screw 

 

Note: The full range from minimum flow to maximum flow is only ¼ turn

 

 

TROUBLESHOOTING

 

PROBLEM 

CAUSE 

RECTIFICATION 

Inconsistent flow 

Blocked top assembly or 
regulating screw 

Remove top assembly and/or regulating 
screw and clean  

Water is not flowing from tap 

Water is turned off 

Turn on water 

Blocked regulating screw 

Remove regulating screw and clean  

Continuous flow 

Top assembly loose or internally 
obstructed or damaged 

Remove top assembly, clean with water 
and re-grease spindle if required 

Rate of flow inadequate 

The flow regulator screw may 
not be adjusted correctly 

Remove blanking screw and adjust flow 
regulating screw as described 

Lever hard to press 

The mains pressure may be too 
great 

Reduce to below 500kPa (70PSI). 
Regrease spindle if required

 

 
 

 

BLANKING SCREW 

Отзывы: