Galvin Engineering Ezy-Drink Lead Safe 170.50.14.00 Скачать руководство пользователя страница 2

 

 

Version 1, 4 February 2020, Page 

2

 of 

4

 

PRE-INSTALLATION -

 MOUNTING DETAILS

 

 

If the mounting holes do not already exist, mark out and drill the holes in the wall/sheet, as shown in 
rough-in dimensions. 

 

Note: Before installation, all lines must be flushed.  We recommend that a line strainer be installed 

prior to drinking taps to eliminate any foreign material. 

 

 

 

 

INSTALLATION

 

IMPORTANT:  Galvin  Specialised  products  must  be  installed  in  accordance  with  these installation  instructions  and  in 
accordance  with  AS/NZS  3500,  the  PCA  and  your  local  regulatory  requirements.  Water  and/or  electrical  supply 
conditions must also comply to the applicable national and/or state standards. Failing to comply with these provisions 
shall void the product warranty and may affect the performance of the product.

 

 

 

1. Fit tap assembly 

  Fit wall plugs to wall as per rough-in 

dimensions. 

  When applying thread tape or sealant to 

the inlet, ensure the opening is not 
obscured. Failure to do so may restrict or 
block the flow restrictor, affecting the flow 
of water. 

  Screw tap onto existing spud until the 

flange is touching the wall. 

  Ensure the mouthguard is in the correct 

position and the holes in the flange align 
with the wall plugs. 

2. Secure the body 

  Secure the body with supplied screws. 

 
 

Rough-in Dimensions 