Galvin Engineering CliniLever TCWSC150C Скачать руководство пользователя страница 5

 

 

Version 2, 12 July 2022, Page 

5

 of 

5

 

Product Installation Guidelines 

Document No.: 001.00.10.08 

 

Version 1, 12 July 2022, Page 

5

 of 

5

 

SERVICE AND MAINTENANCE

 

JUMPER VALVE TAPWARE 

CERAMIC DISC TAPWARE 

1.  Turn off the water supply and turn on the tap 

handle to drain water from the bodies. 

2.  Remove the temperature indicator from the 

handle.  

3.  Remove the handle from the tap. 

4.  Unscrew the top assembly from the body. 

5.  Check the o-ring on the spindle and the 

jumper valve for wear and damage.  
Replace if required. 

6.  Clean the spindle and body of debris. 

7.

  Place a new o-ring (if required) onto the 

spindle and re-grease with potable water 
approved grease.

 

8.

  Re-assemble top assembly. Follow the product 

installation guidelines for the relevant product 
to re-assembly method.

 

1.  Turn off the water supply and turn on the tap 

handle to drain water from the bodies. 

2.  Remove the temperature indicator from the 

handle. 

3.  Remove the handle from the tap. 

4.  Unscrew the ceramic head part from the 

body. 

5.  Check the o-ring on the ceramic head part 

for wear and damage. Replace if required. 

6.  Clean the head part and the body of any 

debris. 

7.  Replace the cartridge and hand tighten back 

into the body. 

8.  Follow the product installation guidelines for 

the relevant product to re-assemble. 

 

WARRANTY

 

The warranty set forth herein is given expressly and is the only warranty given by the Galvin Engineering 
Pty  Ltd.  With  respect  to the  product,  Galvin  Engineering  Pty  Ltd  makes  no  other  warranties,  express  or 
implied. Galvin Engineering Pty. Ltd. hereby specifically disclaims all other warranties, express or implied, 
including but not limited to the implied warranties of merchantability and fitness for a particular purpose. 
 
Galvin Engineering Pty Ltd products are covered under our manufacturer’s warranty available for download 
from www.galvinengineering.com.au  Galvin Engineering Pty Ltd expressly warrants that the product is free 
from operational defects in workmanship and materials for the warranty period as shown on the schedule 
in the manufacturer’s warranty. During the warranty period, Galvin Engineering will replace or repair any 
defective  products  manufactured  by  Galvin  Engineering  without  charge,  so  long  as  the  terms  of  the 
Manufacturer’s warranty are complied with. 
 
The remedy described in the first paragraph of this warranty shall constitute the sole and exclusive remedy 
for breach of warranty, and Galvin Engineering Pty Ltd shall not be responsible for any incidental, special 
or consequential damages, including without limitation, lost profits or the cost of repairing or replacing other 
property which is damaged if this product does not work properly, other costs resulting from labour charges, 
delays, vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions, 
chemical, electrical or any other circumstances over which Galvin Engineering has no control. This warranty 
shall be invalidated by any abuse, misuse, misapplication, improper installation or improper maintenance 
or alteration of the product.

 

 

Содержание CliniLever TCWSC150C

Страница 1: ...educe the spread of legionella Smooth round design to facilitate easy cleaning and to help reduce dirt and bacterial growth Quick action SBA s includes brass jumper valve ceramic disc component with red and blue indicator buttons on 80mm or 150mm lever action handles IMPORTANT All CliniLever healthcare taps are tested in accordance with AS NZS 3718 and leave our premises in good working order TECH...

Страница 2: ...unted between 0 and 15mm behind the finished wall surface Wall spud Wall spud must be BSP male thred and protrude from the finished wall by no more than 15mm Note In some situations a male thread connection on the spout may be more suited If so please contact us on 1300 514 074 Note Before installation all lines must be flushed We recommend that a line strainer be installed prior to taps to elimin...

Страница 3: ...r the elbow Fit the elbow to the protruding wall spud We recommend using thread tape or an equivalent to ensure the connection does not leak Ensure spout connection is pointing up vertical 2 Refit the spout Refit the spout to the elbow Tighten the grub screw using a hex key Note Do not overtighten grub screw Ensure spout swivels freely once installed 3 Fit Spindle Assembly Remove handle and flange...

Страница 4: ...lace jumper valve Ceramic discs are worn or damaged Remove and inspect SBA Remove debris and or replace SBA if damaged Tap seat is damaged Refurbish tap seat using a reseating tool Water is leaking from spindle O ring on jumper valve spindle is damaged or worn Replace o ring Water is not flowing from tap Water is turned off Turn water on Aerator or flow regulator is blocked by debris Remove aerato...

Страница 5: ...Galvin Engineering Pty Ltd makes no other warranties express or implied Galvin Engineering Pty Ltd hereby specifically disclaims all other warranties express or implied including but not limited to the implied warranties of merchantability and fitness for a particular purpose Galvin Engineering Pty Ltd products are covered under our manufacturer s warranty available for download from www galvineng...