![Galvin Engineering 49920 Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/galvin-engineering/49920/49920_installation-manual_3297734003.webp)
© Galvin Engineering Pty Ltd
Product Installation Guidelines
Version 1, 7 October 2022, Page
3
of
4
3
.
Testing
−
Once temperature indicator is fitted, check the operation of the unit and inspect for any leaks.
TROUBLESHOOTING
PROBLEM
CAUSE
RECTIFICATION
Taps are dripping water
Jumper valves are worn or damaged
Replace jumper valve
Tap seat is damaged
Refurbish tap seat using a
reseating tool.
Water is leaking from spindle
O-ring on jumper valve spindle is
damaged or worn
Replace o-ring
Water is not flowing from tap
Water is turned off
Turn water on
Spindle is difficult to turn
Build up of scale on spindle, spindle
worn or o-ring has been damaged
Remove jumper valve, clean and
regrease. Replace o-ring.
Complete SBA may need to be
replaced.
Handle is loose
Screw has come loose
Tighten locking ring
SERVICE AND MAINTENANCE
1. Turn off the water supply and turn on the tap handle to drain water from the bodies.
2. Remove the temperature indicator from the handle.
3. Remove the handle from the tap.
4. Unscrew the top assembly from the body.
5. Check the o-ring on the spindle and the
jumper valve for wear and damage.
Replace if required.
6. Clean the spindle and body of debris.
7. Place a new o-ring (if required) onto the spindle and re-grease with potable water approved grease.
8. Re-assemble top assembly. Follow the product installation guidelines for the relevant product to re-
assembly method.