Galvin Engineering 49920 Скачать руководство пользователя страница 3

 

© Galvin Engineering Pty Ltd 

 

Product Installation Guidelines 

Version 1, 7 October 2022, Page 

3

 of 

4

 

 

 

3

.

 Testing 

 

Once temperature indicator is fitted, check the operation of the unit and inspect for any leaks.

 

 

 

TROUBLESHOOTING 

PROBLEM 

CAUSE 

RECTIFICATION 

Taps are dripping water 

Jumper valves are worn or damaged 

Replace jumper valve 

Tap seat is damaged 

Refurbish tap seat using a 
reseating tool. 

Water is leaking from spindle 

O-ring on jumper valve spindle is 
damaged or worn 

Replace o-ring 

Water is not flowing from tap 

Water is turned off 

Turn water on 

Spindle is difficult to turn  

Build up of scale on spindle, spindle 
worn or o-ring has been damaged 

Remove jumper valve, clean and 
regrease. Replace o-ring. 
Complete SBA may need to be 
replaced. 

Handle is loose 

Screw has come loose 

Tighten locking ring 

 

SERVICE AND MAINTENANCE

 

1.  Turn off the water supply and turn on the tap handle to drain water from the bodies. 

2.  Remove the temperature indicator from the handle.  

3.  Remove the handle from the tap. 

4.  Unscrew the top assembly from the body. 

5.  Check the o-ring on the spindle and the 

jumper valve for wear and damage.  
Replace if required. 

6.  Clean the spindle and body of debris. 

7.  Place a new o-ring (if required) onto the spindle and re-grease with potable water approved grease. 

8.  Re-assemble top assembly. Follow the product installation guidelines for the relevant product to re-

assembly method. 

Отзывы: