PRE-INSTALLATION - 

MOUNTING DETAILS

 

Wall Spud 
 

− Wall spuds must be 15BSP MI and protrude from the finished wall by no more than 15mm  

Note:  In some situations a male thread connection on the tap may be more suited. If so, please 
contact Galvin Specialised on 1300 514 074.

 

 

    

 

INSTALLATION

 

IMPORTANT:  Galvin  Specialised  products  must  be  installed  in  accordance  with  these  installation 
instructions and  in accordance with AS/NZS 3500, the PCA and your local regulatory requirements.  Water 
and/or  electrical  supply  conditions  must  also  comply  to  the  applicable  national  and/or  state  standards. 
Failing  to comply  with these  provisions  shall  void  the  product  warranty  and  may  affect  the  performance  of 
the product. 

 

 

1. Fit washing machine body 

 

Fit the washing machine body assembly to the 
spud and fasten with a spanner.

 

 

We recommend using thread tape or 
equivalent to ensure the connection does not 
leak.

 

 

DO NOT tighten the body by using the top 
assembly.

 

2. Fit handle 

 

Ensure the spindle is in the closed position 
then fit bonnet and handle 

 

 

Secure the handle using the 

“C” circlip and 

locking ring.

 