5. Technical specification
5.8. Technical specification of the SGW(S)B Tower Biwal 200-1500
Specification
Unit
SGW(S)B Tower Biwal
200
250
300
400
500
700
1000
1500
Storage capacity
1
l
197
244
299
395
496
683
992
1420
Nominal capacity
l
210
259
322
420
525
705
1019
1442
Tank's max. working temp.
°C
95
95
95
95
95
95
95
95
Coil's max. working temp.
°C
110
110
110
110
110
110
110
110
Tank's max. working pressure
MPa
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
Coil's max. working pressure
MPa
1,6
1,6
1,6
1,6
1,6
1,6
1,6
1,6
Solar coil's surface
m
2
1,0
1,2
1,4
1,8
2,0
2,4
2,7
2,7
Solar coil's power (70/10/45°C)
kW
24
29
33,6
43
48
57,6
64,8
64,8
Solar coil's efficiency
l/h
570
635
800
1030
1150
1380
1580
1580
CH coil's surface
m
2
0,7
0,7
1,1
1,1
1,1
1,2
1,5
1,5
CH coil's power (70/10/45°C)
kW
17
17
26,4
26,4
26,4
28,8
36
36
CH coil's efficiency
l/h
410
410
630
630
630
690
880
880
Magnesium
anode
5/4" plug
3
38x400
38x400
38x400
38x400
38x600
38x600
38x600
38x600
M8 screw
38x200
38x200
38x200
38x400
38x200
38x400
38x400
38x400
Connections of the SGW(S)B 100-400, 700, 1000 water heaters
h1 - Cold water inlet
G" / mm 1 / 130
1 / 210
1 / 130
1 / 240
-
6
⁄
4
/ 215
6
⁄
4
/ 250
-
h2 - Water outflow to solar collector
G" / mm 1 / 210
1 / 290
1 / 280
1 / 320
-
1 / 375
1 / 450
-
h3 - Sensor cover I
G" / mm R
3
⁄
8
/ 355 R
3
⁄
8
/ 400 R
3
⁄
8
/ 435 R
3
⁄
8
/ 570
-
R
3
⁄
8
/ 575 R
3
⁄
8
/ 590
-
crk - Circulation
G" / mm ¾ / 450
¾ / 595
¾ / 650
¾ / 770
-
5
⁄
4
/ 925
5
⁄
4
/ 880
-
h4 - Hot water inflow from solar collector G" / mm 1 / 550
1 / 695
1 / 750
1 / 870
-
1 / 1045
1 / 1000
-
h5 - CH water outflow
G" / mm 1 / 635
1 / 795
1 / 860
1 / 980
-
1 / 1175
1 / 1100
-
h6 - Sensor cover II
G" / mm
3
⁄
8
/ 765
3
⁄
8
/ 900
3
⁄
8
/ 1030
3
⁄
8
/ 1150
-
3
⁄
8
/ 1365
3
⁄
8
/ 1250
-
h7 - CH hot water inflow
G" / mm 1 / 895
1 / 1005
1 / 1200
1 / 1330
-
1 / 1555
1 / 1440
-
h8 - DHW outflow
G" / mm 1 / 975
1 / 1085
1 / 1355
1 / 1470
-
6
⁄
4
/ 1715
6
⁄
4
/ 1570
-
Connections of the SGW(S)B 500, 1500 water heaters
h1 - Cold water inlet
G" / mm
-
-
-
-
1 / 180
-
-
6
⁄
4
/ 250
h2 - Water outflow to solar collector
G" / mm
-
-
-
-
1 / 320
-
-
1 / 450
h3 - Sensor cover I
G" / mm
-
-
-
-
R
3
⁄
8
/ 530
-
-
R
3
⁄
8
/ 600
h4 - Hot water inflow from solar collector G" / mm
-
-
-
-
1 / 970
-
-
¾ / 1000
h5 - CH water outflow
G" / mm
-
-
-
-
1 / 1090
-
-
1 / 1100
h6 - Sensor cover II
G" / mm
-
-
-
-
R
3
⁄
8
/ 1200
-
-
R
3
⁄
8
/ 1250
crk - Circulation
G" / mm
-
-
-
-
¾ / 1320
-
-
5
⁄
4
/ 1630
h7 - CH hot water inflow
G" / mm
-
-
-
-
1 / 1440
-
-
1 / 1435
h8 - DHW outflow
G" / mm
-
-
-
-
1 / 1650
-
-
6
⁄
4
/ 2250
Dimensions
Coupler for an electrical set
G"
6/4
6/4
6/4
6/4
6/4
6/4
6/4
6/4
Inspection hole
Ø
180/120
180/120
180/120
180/120
180/120
280/205
280/205
280/205
d - Internal diameter
Ø
550
550
550
600
630
700
900
900
D - External diameter
Ø
670
670
670
700/800
2
755/840
2
855/860
2
1055/1060
2
1100
2
L - Height with insulation
mm
1140
1300
1615
1750
1950
2050/2080
2
1960/1990
2
2680
2
Weight (empty)
kg
98
115
140
151
177
296
475
580
1
In accordance with the Commission Regulation (UE) 812/2013, 814/2013.
2
Detachable Neodul insulation.
3
Capacities 700, 1000 and 1500 l - magnesium anode plug 2".