background image

10

11

On-

Off push button. After any monitor reset and during the next 45 seconds,

     all the monitor functions will be disabled, with the exception of call reception.

If the handset is on the craddle allows the activation of an optional second camera (*).

     If not, allows to make an intercom call or to activate the second camera (*).

If the handset is on the craddle allows the activation of an optional device. If not,

     allows to call to a slave porter's exchange (*) or to activate the optional device.

If the handset is on the craddle allows to see the picture from the master door panel.

     If not, allows to establish audio and video communication with the door panel

     that has been configurated with the autoswitch-

on function. This function is

     disabled if a communication is already established.

If the handset is on the craddle sends a panic call to the porter's exchanges that

     have enabled the reception of this type of call. If not, allows to call to the master

     porter's exchange. During call reception and communication progresses allows

     the lock release activation.

Monitor

Modelo

CODIGO / CODE

MASTER

18Vdc

±

2

V

S

ta

n

dby

1

5mA

Máximo

  450mA

Sistemasde

comunicaciónS

.A.

Madein

Sp

ain

10ºC + 50ºC

SLA

V

E

INTER

A

1

PUER

T

A

ESCALERA

AT

E

N

C

N

Alt

a

 tensión.

No abrir

la t

a

p

a

.

Manipular

s

ólo por

p

ersonal

del servicio técnico.

W

A

RNING

High volt

age.

Don't

o

pen cover

.

Handle only by technical

service.

PISO

Floor

D

oor

St

a

ir

PLA

T

EA

Plus

0000000000

serie

a

f

g

b

e

j

l

k

m

d

i

c

h

a.

b.

c.

d.

e.

f .

g.

h.

i .

j .

k.

l .

m.

Handset.

B/W or color screen (depending on the model).

Front film.

Function push buttons.

Cord.

Attachment holes.

Identification label.

Connecting points.

CN4 connector

.

Three positions call reception volume control.

Cable slot.

Contrast control (color control in case of color screen).

Brightness control.

Monitor

Modelo

CODIGO

/

C

ODE

MASTER

18Vdc

±

2V

S

tandby

1

5mA

Máximo

450mA

Sistemasde

comunicaciónS.A.

Madein

Sp

ain

10ºC

+

5

0ºC

SLA

V

E

INTER

A

1

PUER

T

A

ESCALERA

A

T

ENCIÓN

Alt

a

tensión.

No

abrir

la

ta

p

a

.

Manipular

sólo

por

p

ersonal

del

s

ervicio

técnico.

W

A

RNING

High

volt

age.

Don't

o

pen

c

over

.

Handle

only

b

y

technical

service.

PISO

Floor

D

oor

S

tair

PLA

T

EA

Plus

0000000000

serie

(*) Second camera activation and call to a slave porter's exchange functions require an internal

        modification of the monitor

. If any of these functions are required, contact with your nearest

        authorized distributor

.

        Second camera activation disables the intercomm function and call function to a slave

        porter's exchange disables optional device function.

MONIT

OR DESCRIPTION

MONIT

OR DESCRIPTION

escription of the Platea Plus monitor

.

D

unction push buttons.

F

escription of the identification label.

D

For an easiest repair

, replacement or increasement

     of the existing monitors, fill the indentifying label

     information.

MASTER: master monitor

.

SLA

VE

: slave monitor

.

INTER: slave monitor with intercom function.

A1: monitor connected to an auxiliary device.

CODE

: push button code (see page 5).

ST

AIR: building code (see page 7).

Содержание 295 series

Страница 1: ...T300EN rev 0204 Instructions manual Audio and Video door entry system digital installation 295 Series ...

Страница 2: ...Troubleshooting hints 29 INTRODUCTION First of all we would like to thank and congratulate you for the purchase of this product manufactured by Golmar The commitment to reach the satisfaction of our customers is stated through the ISO 9001 certification and for the manufacturing of products like this one Its advanced technology and exacting quality control will do that customers and users enjoy wi...

Страница 3: ...ithout the visitor being aware of this To see the picture in a slave monitor press the push button dissapearing the picture on the other monitor If the call is not answered in 45 seconds the system will be freed O To establish communication pick up the monitor telephone handset The communication will last for one and a half minutes or until the handset is replaced Once the communication has finish...

Страница 4: ...e CD 295 2nd push buttons module CD 295 2nd push buttons module CD 295 L1 L2 CD1 CN2 CD2 CP L1 L2 CN1 CP CD L1 L2 CN1 CP CD 1 9 17 3 11 19 5 13 21 7 15 23 8 16 24 6 14 22 4 12 20 2 10 18 DOOR PANEL INSTALLATION old the door panel on the embedding box H Insert the hinge in the embedding box lockers Press the hinge ends to insert them in the door panel lockers as shown oor panel wiring D Open the te...

Страница 5: ...general entrance panel this function can be activated in one door panel of each internal building Set to ON the switch number 2 for monitor or telephones programming Once the programming progress is finished return the switch to OFF position The programming process is described on pages 15 monitors and 18 telephones Set to OFF the switch number 3 in case of a master door panel Each system must hav...

Страница 6: ...or panel C Fix the door panel to the embedding box by using the supplied vandal resistant screws and the special screwdriver inal adjustments F To install the power supply directly on the wall drill two holes of Ø6 mm and insert the wallplugs Fix the transformer with the specified screws The power supply can be installed on a DIN 46277 guide simply pressing it To disassemble the power supply from ...

Страница 7: ...O Floor Door Stair PLATEA Plus 0000000000 Nº serie a f g b e j l k m d i c h a b c d e f g h i j k l m Handset B W or color screen depending on the model Front film Function push buttons Cord Attachment holes Identification label Connecting points CN4 connector Three positions call reception volume control Cable slot Contrast control color control in case of color screen Brightness control Monitor...

Страница 8: ...tional device activation output twisted pair video signal Vin Malla Vout A D HZ INT SA CTO 2C A1 Vp Mp L561 module for video installations E with twisted pair cable andling the end of line jumper H hanging the front film C The end of line jumper is placed on the CN4 connector that can be located on the monitor base In case of twisted pair cable installations the end of line jumper is placed in the...

Страница 9: ...de In systems with more than one door panel the programming process shall be done on the master door panel only Switch off the monitor to be programmed Once the monitor is off press the door release push button With the door release push button pressed switch on the monitor To show that the system is ready for programming the door panel will reproduce a sound and the picture will appears on the mo...

Страница 10: ...allows to call to the master porter s exchange During call reception and communication progresses allows the lock release activation a b c a b c erminal connector description Tpositive ground audio digital communication intercom auxiliary calling device output door bell push button input A D INT SA HZ A D _ SA INT HZ TELEPHONE INSTALLATION ix the telephone F It will be necessary to open the teleph...

Страница 11: ...aves both monitors or telephones Make a call to check that the telephone has been succesfully programmed Repeat these steps to program the rest of telephones Once the programming has been finished set to OFF the programming switch If you don t the door panel will reproduce a sound to advise that the system is still into programming mode INSTALLATION DIAGRAMS onnexion of an a c lock release C As it...

Страница 12: ...el as shown on the diagram In case of more than two door panels wire them as the second is connected 1 00mm 2 50mm 0 25mm 0 25mm RG 59 RG 59 Terminal SECTIONS CHART 50m Distance 150m A A A D in out V V V V in out in out CV CV For longer distances than the specified contact with your distributor Take off JP1 jumper of all the distributors except in the last one FA Plus C SEC PRI SEC PRI SW1 SW1 CV ...

Страница 13: ...er distances than the specified contact with your distributor ideo installation without coaxial cable v The installation diagram shows the connection of a video system with one or several door panels for the same building If the system has one door panel only override the wiring to the second door panel If the system has more than one door panel wire the second panel as shown on the diagram In cas...

Страница 14: ...panels for the same building If the system has one door panel only override the wiring to the second door panel If the system has more than one door panel wire the second panel as shown on the diagram In case of more than two door panels wire them as the second is connected For longer distances than the specified contact with your distributor FA Plus C SEC PRI SEC PRI SW1 SW1 CV CV CV CV D D Malla...

Страница 15: ...SCART connector it will be possible to view the picture from the door panel on the TV screen Remove the end of line jumper that s placed on the CN4 connector Connect the coaxial cable between terminals 17 shield and 20 hot of the SCART connector ntercom function I Platea Plus monitor and T 940 Plus telephone have intercom facility between two units of the same apartment To enable this function che...

Страница 16: ...e wiring from the door panel and to check a monitor or telephone directly connected to the door panel No shortcircuit will damage the connected units with the exception of a shortcircuit between CTO and monitor or distributor terminals O Nothing operates w Check the output power supply voltage between and terminals it should have 17 5 to 18 5Vd c If not disconnect the power supply from the install...

Страница 17: ... el derecho a cualquier modificación sin previo aviso Golmar se réserve le droit de toute modification sans préavis Golmar reserves the right to make any modifications without prior notice golmar golmar es www golmar es ...

Отзывы: