Gallien-Krueger MB200 Скачать руководство пользователя страница 3

3

MB SERIES

C A U T I O N

RISK OF ELECTRIC SHOCK

DO NOT OPEN

!

!

C A U T I O N :

WARNING:

TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT

REMOVE TOP COVER. NO USER-SERVICEABLE PARTS

INSIDE. REFER SERVICING TO QUALIFIED SERVICE

PERSONNEL.

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,

DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE

                  The lightning flash with arrow

head symbol, within the

equilateral triangle, is

intended to alert the user to the

presence of uninsulated “dangerous voltage”

within the product inclosure that may be of

sufficient magnitude to constitute

a risk of electitric shock to persons

               The exclamation point within an

equilateral triangle, is intended

               to alert the user to the presence

of important operating and

maintenance (servicing) instructions in the

literature accompanying the appliance.

C A U T I O N :

ATTENTION:

TO PREVENT ELECTRIC SHOCK, MATCH WIDE BLADE OF PLUG TO

WIDE SLOT, FULLY INSERTED.

POUR EVITER LES CHOCS ELECTRIQUES, INRODUIRE LA LAME LA

PLUS LARGE DE LA FICHE DANS LA BORNE CORRESPONDANTE

DE LA PRISE ET POUSER JUSQU’AU FOND.

Table Of Contents 

Safety Information __________________________ Pg.  4

Quick Start ________________________________ Pg. 5

Front Panel Controls ________________________ Pg. 6

Sound Tips   ________________________________Pg. 7

Installation and Maintenance ___________________Pg. 8

Tech Talk   ________________________________Pg. 9

Specifications ______________________________Pg. 10

*All Features and specifications are subject to change without notice 

Please read the Safety Information section on page 4 and installation

instructions on page 12 before continuing. 

Gallien-Krueger 

2234 Industrial Drive 

Stockton, CA 95206 

phone: 209.234.7300 

fax: 209.234.8420 

email: [email protected] 

internet: www.gallien-krueger.com 

Warning!

This amplifier is capable of producing high sound pressure levels.

Continued exposure to high SPL’s can cause damage to your hearing.

Always set the volume at a safe listening level or use hearing

protection if the unit is operated at higher levels.

Содержание MB200

Страница 1: ...MB 200 OWNER S MANUAL ...

Страница 2: ...ntact your local dealer or GK as soon as possible Gallien Krueger Inc 2234 Industrial Drive Stockton CA 95206 phone 209 234 7300 fax 209 234 8420 Internet www gallien krueger com Email info gallien com We wish you a lifetime of good playing and remember to always have fun GK Philosophy I have never seen the point in doing things the way others have done them I also have not been very interested in...

Страница 3: ...UR EVITER LES CHOCS ELECTRIQUES INRODUIRE LA LAME LA PLUS LARGE DE LA FICHE DANS LA BORNE CORRESPONDANTE DE LA PRISE ET POUSER JUSQU AU FOND Table Of Contents Safety Information __________________________ Pg 4 Quick Start ________________________________ Pg 5 Front Panel Controls ________________________ Pg 6 Sound Tips ________________________________Pg 7 Installation and Maintenance ____________...

Страница 4: ... Power Cord To avoid safety hazards use only the power cord supplied with your unit If a replacement cord is needed make certain to use a standard IEC compliant cord Damaged power cords should be replaced immediately When setting up make certain thattheACplugiseasilyaccessible Ifyoudo not intend to use the amplifier for a considerable length of time disconnect the plug from the AC Mains Socket Do ...

Страница 5: ...s noted below Maximum Recommended Speaker Loads One 4 Ohm or two 8 Ohm cabinets 3 Initial front panel control settings Set all EQ controls and contour knob to 12 o clock Set the input volume controls at 0 4 Plug in your bass Using an instrument shielded cable connect your bass to the Input jack and press the power switch on If you have active tone controls on your bass turn all of the controls to ...

Страница 6: ... used to control the low end push turned up Power Switch Turns the amplifier on and off In the on position the ring surrounding the button will light red during power up then changes to blue indicating the amp is ready for normal operation Should the amp experience a fault over heat or over current the amp will mute and the ring will light red until the condition is corrected This LED turns off wh...

Страница 7: ...ed for midrange clarity at higher playing levels Direct Out The MB Series provides a low noise high quality balanced direct output for connection to PA and recording consoles A ground lift switch is included to remove hum and buzz when connecting to equipment powered by a different ground system With the pre post EQ switch set to pre out the direct output signal is fed directly from the input stag...

Страница 8: ... and the other equipment Moving the Unit Before moving the unit be certain to disconnect any interconnection cords with other components and make sure that you disconnect the unit from the AC outlet Cleaning When the unit gets dirty clean only with a dry cloth Never use benzene thinner alcohol or other volatile cleaning agents Do not use abrasive cleaners as they may damage the finish of metal par...

Страница 9: ... control all the way up the low end is slightly boosted the mids are dropped and the high end is pushed up This is only found in GK amplifiers Cool Running Reliability To cool the amp when its being driven hard we ve designed a temperature sensitive fan cooling system When the amp is under a light load the fan is off or running at a low speed reducing fan noise As the amp works harder the fan spee...

Страница 10: ... Bass Lo Mid Hi Mid Treble Voicing Filters Contour 140W 8 Ohms 200W 4 Ohms 0 6V Rms 1 6V Rms 1M Ohms 500 Ohms 100K Ohms 10dB 60Hz 6dB 10dB 250Hz 6dB 10dB 1KHz 14dB 7KHz 2dB 50Hz 10dB 500Hz 3dB 7 KHz Noise 90 dB reference to 200W 140W A Weighted Amplifier Protection Full short circuit thermal and RF protection Stable into reactive and mismatch loads Five second muted warm up Cooling Variable speed ...

Отзывы: