INSTALLATION, OPERATION AND MAINTENANCE 

 

IMPORTANT:    THIS  APPLIANCE  MUST  BE  INSTALLED  BY  A  COMPETENT  PERSON  AND  THE 
INSTALLATION  MUST  COMPLY  WITH  BS8303  –  CODE  OF  PRACTICE  FOR  INSTALLATION  OF 
DOMESTIC  HEATING  AND  COOKING  APPLIANCES  BURNING  SOLID  MINERAL  FUEL,  NATIONAL 
BUILDING  REGULATIONS,  LOCAL  BY-LAWS  AND  STANDARDS  AND  THE  REQUIREMENTS  OF  THE 
HEALTH AND SAFETY AT WORK ACT - IN PARTICULAR: 
 
HANDLING  – 

ADEQUATE  FACILITIES  MUST  BE  AVAILABLE  FOR  LOADING,  UNLOADING  AND  SITE 

HANDLING. 

 
FIRE  CEMENT  – 

SOME  TYPES  ARE  CAUSTIC  AND  SHOULD  NOT  BE  ALLOWED  TO  COME  INTO 

CONTACT WITH THE SKIN. IN CASE OF CONTACT WASH IMMEDIATELY WITH PLENTY OF WATER. 

 
ASBESTOS  – 

THESE  STOVES  CONTAIN  NO  ASBESTOS.    IF  THERE  IS  A  POSSIBILITY OF  DISTURBING 

ANY  ASBESTOS  IN  THE  COURSE  OF  INSTALLATION  THEN  PLEASE  SEEK  THE  GUIDANCE  OF  A 
SPECIALIST AND USE APPROPRIATE PROTECTIVE EQUIPMENT. 

 
METAL PARTS – 

WHEN INSTALLING OR SERVICING THIS STOVE CARE SHOULD BE TAKEN TO AVOID 

THE POSSIBILITY OF PERSONAL INJURY 

 
UNLESS  THE  INSTALLER  IS  QUALIFIED  TO  APPROVE  INSTALLATION  THEN  APPROVAL  MUST  BE 
SOUGHT  FROM  YOUR  LOCAL  BUILDING  CONTROL  DEPARTMENT.    THE  SUPPLIERS  ACCEPT  NO 
RESPONSIBILITY  IF  THIS  ADVICE  IS  NOT  FOLLOWED.    THIS  APPLIANCE  HAS  BEEN  EXTENSIVELY 
TESTED FOR SAFETY AND EFFICIENCY, DO NOT ATTEMPT TO MODIFY IT.  ALWAYS USE GENUINE 
REPLACEMENT  PARTS  AS  RECOMMENDED  BY  YOUR  SUPPLIER.    FAILURE  TO  ADHERE  TO  THIS 
ADVICE WILL INVALIDATE YOUR GUARANTEE. 
 
TRY  TO  AVOID  FITTING  THE  STOVE  INTO  A  ROOM  WITH  AN  EXTRACTOR  FAN.    IF  THIS  IS 
UNAVOIDABLE  THEN  SEEK  SPECIALIST  ADVICE  TO  ENSURE  THAT  THE  INSTALLATION  IS  TESTED 
FOR SAFETY.  A SUITABLE TEST COMPRISES CHECKING FOR SPILLAGE IF THE ROOM WHERE THE 
APPLIANCE  IS  FITTED  IS  SUBJECTED  TO  THE  GREATEST  POSSIBLE  DEPRESSURISATION.    THIS 
MEANS FIRING THE APPLIANCE WITH ALL THE EXTRACT FANS IN THE BUILDING OPERATING AT 
THEIR MAXIMUM AND WITH  ALL DOORS, ADJUSTABLE VENTILATORS AND WINDOWS CLOSED.  
IF SPILLAGE OCCURS THEN ADDITIONAL PERMANENT VENTILATION DIRECT FROM OUTSIDE WILL 
BE REQUIRED.  ONCE THE ADDITIONAL VENTILATION IS FITTED, RETEST AS NOTED ABOVE, 
DO  NOT  FIT  AN  EXTRACTOR  FAN  INTO  THE  SAME  ROOM  AS  THE  STOVE  AFTER  IT  HAS  BEEN 
INSTALLED AS IT MAY CAUSE THE STOVE TO EMIT FUMES 

 

IT IS ESSENTIAL AND  REQUIRED BY BUILDING REGULATIONS  THAT A CARBON MONOXIDE (CO) 
ALARM IS INSTALLED IN THE SAME ROOM AS THIS STOVE. 
 
THIS STOVE MUST HAVE ITS OWN CHIMNEY AND MUST NOT SHARE A CHIMNEY WITH ANOTHER 
APPLIANCE. 
 
THIS STOVE IS FOR INTERMITTENT USE ONLY AND SHOULD BE SHUT DOWN OVERNIGHT. 
 
VENTILATION MAY BE REQUIRED INTO YOUR ROOM, PLEASE SEE PAGE 9. 

Содержание HELIOS

Страница 1: ...QUALIFIED AND COMPETENT INSTALLERS PLEASE LEAVE THIS BOOKLET WITH THE HOUSEHOLDER Gallery Stoves operate at very high temperatures All persons including children and the infirm should be warned of th...

Страница 2: ...CONTENTS STOVE CONTROLS OUTPUT EFFICIENCY PAGE 03 COMPONENT PARTS PAGE 04 INSTALLATION PAGE 05 OPERATION PAGE 10 GENRAL MAINTENANCE PAGE 16 SAFETY NOTES TROUBLESHOOTING PAGE 18 STOVE ACCESSORIES PAGE...

Страница 3: ...nmental Services in the Netherlands Variations may occur due to installation atmospheric conditions and fuel quality HELIOS 5 CB FUEL WOOD ANTHRACITE EFFICIENCY 82 8 83 4 FLUE GAS TEMPERATURE 224 C 21...

Страница 4: ...use components made specifically for your stove ITEM DESCRIPTION ITEM DESCRIPTION 1 Stove body 8 Flue blanking plate 2 Hinge set 9 Primary air slide assembly 3 Door casting 10 Fuel retaining bar 4 Sid...

Страница 5: ...OWED THIS APPLIANCE HAS BEEN EXTENSIVELY TESTED FOR SAFETY AND EFFICIENCY DO NOT ATTEMPT TO MODIFY IT ALWAYS USE GENUINE REPLACEMENT PARTS AS RECOMMENDED BY YOUR SUPPLIER FAILURE TO ADHERE TO THIS ADV...

Страница 6: ...lean the appliance flue ways flue pipe and chimney prior to lighting up after a prolonged shut down period Check the chimney is in good condition dry and free of cracks leaks and obstructions The diam...

Страница 7: ...that it should be swept every twelve months thereafter If used regularly it is recommended that your chimney is swept every six months An existing fireplace opening can be modified to accommodate the...

Страница 8: ...a stainless steel flexible liner for solid fuel if your chimney is larger than 230mm x 230mm A closure plate with access for cleaning may also be required together with a short length of flue pipe of...

Страница 9: ...ures of up to 200o C Hearths Allow an apron of at least 225mm at the front of the stove and 150mm on either side Care should be taken to level the stove and secure the hearth If existing floors do not...

Страница 10: ...EN THE STOVE DOOR SLOWLY AND ALWAYS USE THE GLOVE Primary Air controllable Primary air is controlled via the sliding vent in the bottom of the door This provides an air draught through the grate to th...

Страница 11: ...long shutdowns to preserve the life of stove During the curing of the paint you may notice an unpleasant smell It is not toxic but for your comfort we would suggest that during this period you leave...

Страница 12: ...ood draft and stove settings so please do experiment to find your own best settings and the best position on your Stove Thermometer Other Solid Fuel Burning Always clean out the ash pan before refuell...

Страница 13: ...o dimension is greater than 3 75mm it would take about 3 years to dry A dry log will produce up to four and a half times more heat output than a freshly cut log Wet logs take heat to dry Other Solid F...

Страница 14: ...as have been authorised and that appliances used to burn solid fuel in those areas other than authorised fuels have been exempted for each area of administration Further information on the requirement...

Страница 15: ...plate drops down from the rear fire brick that it was resting upon The plate can now be withdrawn through the open doorway of the stove To replace place the baffle plate inside the stove in the corre...

Страница 16: ...Stove Paint available from your supplier Glass Panels Clean the glass panels when cool with Gallery Glass Cleaner Highly abrasive substances should be avoided as these can scratch the glass and make...

Страница 17: ...and maintenance of the appliance and chimney system Fires Can Be Dangerous Always use a fire guard to BS 8423 2002 Fireguards for Use With Solid Fuel Appliances in the presence of children the elderl...

Страница 18: ...cause has been identified and corrected If necessary seek professional advice These situations are very dangerous and must NOT be tolerated A list of Qualified Engineers is available from UK Solid Fue...

Страница 19: ...vary in heat value check with your coal merchant as to suitability Dirty Glass Nearly always caused by poor fuel quality check the moisture content of the wood you are burning with a Gallery moisture...

Страница 20: ...phite high temperature paint Stove Glass Cleaner Spare Rope Rope Seal Adhesive CO Detector Gallery Stove Fan Gallery Stove Thermometer Wood Moisture Meter Spare Glove Permanent Ventilators Purpose bui...

Страница 21: ...21 Brought to you by Percy Doughty Co Imperial Point Express Trading Estate Stone Hill Road Farnworth Bolton BL4 9TN 01204 868 550 www percydoughty com...

Отзывы: