Operation with door left open 

Operation  with  the  door  open  can  cause  excess  smoke  and  will  reduce  the 
efficiency of the stove by up to 50% (as well as presenting an obvious fire risk).  
The appliance must not be operated with the appliance door left open except as 
directed in the instructions. 

 
Dampers left open 

Operation  with  the  air  controls  or  appliance  dampers  open  can  cause  excess 
smoke.   The  appliance  must  not  be  operated  with  air  controls,  appliance 
dampers or door left open except as directed in the instructions. 
  

GENERAL MAINTENANCE (o

nly ever carry out maintenance when the stove is cold). 

The following elements of maintenance may be carried out by the householder.  
Any  structural  repairs,  e.g.  panel,  collar  or  stove  pipe  replacement  must  be 
carried out by a suitably qualified installer. 
 

Baffle Plate Removal and Replacement 

Note the position before removal. To remove baffle plate, firmly push the baffle 
plate  upwards  then  bring  forwards  so  that  the  back  edge  of  the  baffle  plate 
drops down from the rear fire brick that it was resting upon.  The plate can now 
be withdrawn through the open doorway of the stove. 
 
To  replace,  place  the  baffle  plate  inside  the  stove  in  the  correct  alignment.  
Angle the plate so that the front edge is higher than the back edge and lift high 
into the stove so that the front edge locates on the steel ledge at the top of the 
stove and the back edge of the plate can be re-positioned on top of the rear fire 
brick. 

Please ensure the baffle plate has been pushed firmly to the back of the 

stove  prior  to  using  the  stove;  this  enables  the  hot  gases  to  leave  the  stove 
safely as intended. 

 

Sweeping the Chimney 

Your chimney should be cleaned each year before starting to use your stove for 
the  winter.    Birds  may  have  nested  in  the  chimney  or  the  masonry  may  have 
cracked.  Both chimney and flue pipe must be swept at least once a year.  It is 
recommended that you have your chimney swept every six months.  It may be 
necessary to sweep more frequently when damp wood is burnt regularly. 
The chimney can be swept through your stove with the baffle plate removed.  It 
is advisable to remove the bricks too in order to avoid accidental damage. 
 

Содержание HELIOS

Страница 1: ...QUALIFIED AND COMPETENT INSTALLERS PLEASE LEAVE THIS BOOKLET WITH THE HOUSEHOLDER Gallery Stoves operate at very high temperatures All persons including children and the infirm should be warned of th...

Страница 2: ...CONTENTS STOVE CONTROLS OUTPUT EFFICIENCY PAGE 03 COMPONENT PARTS PAGE 04 INSTALLATION PAGE 05 OPERATION PAGE 10 GENRAL MAINTENANCE PAGE 16 SAFETY NOTES TROUBLESHOOTING PAGE 18 STOVE ACCESSORIES PAGE...

Страница 3: ...nmental Services in the Netherlands Variations may occur due to installation atmospheric conditions and fuel quality HELIOS 5 CB FUEL WOOD ANTHRACITE EFFICIENCY 82 8 83 4 FLUE GAS TEMPERATURE 224 C 21...

Страница 4: ...use components made specifically for your stove ITEM DESCRIPTION ITEM DESCRIPTION 1 Stove body 8 Flue blanking plate 2 Hinge set 9 Primary air slide assembly 3 Door casting 10 Fuel retaining bar 4 Sid...

Страница 5: ...OWED THIS APPLIANCE HAS BEEN EXTENSIVELY TESTED FOR SAFETY AND EFFICIENCY DO NOT ATTEMPT TO MODIFY IT ALWAYS USE GENUINE REPLACEMENT PARTS AS RECOMMENDED BY YOUR SUPPLIER FAILURE TO ADHERE TO THIS ADV...

Страница 6: ...lean the appliance flue ways flue pipe and chimney prior to lighting up after a prolonged shut down period Check the chimney is in good condition dry and free of cracks leaks and obstructions The diam...

Страница 7: ...that it should be swept every twelve months thereafter If used regularly it is recommended that your chimney is swept every six months An existing fireplace opening can be modified to accommodate the...

Страница 8: ...a stainless steel flexible liner for solid fuel if your chimney is larger than 230mm x 230mm A closure plate with access for cleaning may also be required together with a short length of flue pipe of...

Страница 9: ...ures of up to 200o C Hearths Allow an apron of at least 225mm at the front of the stove and 150mm on either side Care should be taken to level the stove and secure the hearth If existing floors do not...

Страница 10: ...EN THE STOVE DOOR SLOWLY AND ALWAYS USE THE GLOVE Primary Air controllable Primary air is controlled via the sliding vent in the bottom of the door This provides an air draught through the grate to th...

Страница 11: ...long shutdowns to preserve the life of stove During the curing of the paint you may notice an unpleasant smell It is not toxic but for your comfort we would suggest that during this period you leave...

Страница 12: ...ood draft and stove settings so please do experiment to find your own best settings and the best position on your Stove Thermometer Other Solid Fuel Burning Always clean out the ash pan before refuell...

Страница 13: ...o dimension is greater than 3 75mm it would take about 3 years to dry A dry log will produce up to four and a half times more heat output than a freshly cut log Wet logs take heat to dry Other Solid F...

Страница 14: ...as have been authorised and that appliances used to burn solid fuel in those areas other than authorised fuels have been exempted for each area of administration Further information on the requirement...

Страница 15: ...plate drops down from the rear fire brick that it was resting upon The plate can now be withdrawn through the open doorway of the stove To replace place the baffle plate inside the stove in the corre...

Страница 16: ...Stove Paint available from your supplier Glass Panels Clean the glass panels when cool with Gallery Glass Cleaner Highly abrasive substances should be avoided as these can scratch the glass and make...

Страница 17: ...and maintenance of the appliance and chimney system Fires Can Be Dangerous Always use a fire guard to BS 8423 2002 Fireguards for Use With Solid Fuel Appliances in the presence of children the elderl...

Страница 18: ...cause has been identified and corrected If necessary seek professional advice These situations are very dangerous and must NOT be tolerated A list of Qualified Engineers is available from UK Solid Fue...

Страница 19: ...vary in heat value check with your coal merchant as to suitability Dirty Glass Nearly always caused by poor fuel quality check the moisture content of the wood you are burning with a Gallery moisture...

Страница 20: ...phite high temperature paint Stove Glass Cleaner Spare Rope Rope Seal Adhesive CO Detector Gallery Stove Fan Gallery Stove Thermometer Wood Moisture Meter Spare Glove Permanent Ventilators Purpose bui...

Страница 21: ...21 Brought to you by Percy Doughty Co Imperial Point Express Trading Estate Stone Hill Road Farnworth Bolton BL4 9TN 01204 868 550 www percydoughty com...

Отзывы: