IMPORTANT BATTERY INFORMATION
Recharging the battery
Switch the energizer off. Place in sunlight for
3 days with the battery connected OR remove
the battery from the energizer and charge the
battery for 24 hours with a 12 V 1.2A battery
charger in a sheltered, well-ventilated area.
Storing the energizer
Switch the energizer off. Store in a well lit,
sheltered, well-ventilated area so solar panel
keeps battery charged. Recharge battery
before and after storage.
Maintenance free
battery
The battery must not be opened and does not
require maintenance.
Battery replacement
Use only 12 V 7 Ah sealed, valve regulated
(VRLA) rechargeable batteries.
Do not use the energizer with a non-
rechargeable battery.
Removing the battery
Switch the energizer off before removing the
battery.
Disposing the energizer
The battery must be removed from the
energizer before the energizer is disposed.
Disposing the battery
Lead acid batteries must be disposed of safely
according to local regulations.