Output Current
The output current indicates how hard your energizer is working. When your fence
is in good condi
ti
on this reading will be low, typically under 15 Amps. As the load
on the fence increases the current will rise and output voltage will fall. The output
current will typically change with fence condi
ti
ons, seasonal grass growth and wet
weather. A high output current, typically over 40 Amps indicates there is a very high
load or short circuit on the fence.
Output Voltage
Output voltage is an indica
ti
on of how e
ff
ec
ti
ve the shock is on your fence. It is
generally recommended to have 3KV or above on the fence at any
ti
me. If the output
voltage is too low there will not be enough voltage to ‘break’ through the animals
hide and deliver an e
ff
ec
ti
ve shock.
Zone Indicators
The zone indicators show what zones are ac
ti
ve on the fence system. The Energizer
zone ( ) and Earth zone ( ) are always available. Zones 1 – 6 can be added by
installing up to 6 Alarm Kits (G579009). The Alarm Kit plugs into the back of your
M1200i energizer.
Naviga
ti
on Bu
tt
ons
The naviga
ti
on bu
tt
ons allow you to view the performance of di
ff
erent areas of your
fence system. By pressing (
<
) or (
>
) you can scroll through the zone indicators to
view fence or earth voltage. The zone you are looking at is highlighted by the zone
indica
ti
on arrow (
).
Standby Bu
tt
on
Pressing the standby bu
tt
on ( ) turns the energizer pulses on or o
ff
.
Se
tti
ngs Bu
tt
ons
The se
tti
ngs bu
tt
ons allow you to adjust the alarm levels and output voltage of the
energizer. Pressing the setup bu
tt
on (
) turns o
ff
the energizer pulses and enters
setup mode. If no further bu
tt
ons are pressed within 10 seconds the energizer
automa
ti
cally exits setup mode and starts pulsing as normal.
Other Icons
The controller may occasionally display other icons for your informa
ti
on.
Energizer over-temperature. The energizer has detected that its internal
temperature is too high to operate safely and has automa
ti
cally slowed its
pulse rate down.
Se
tti
ngs mode. The user has entered the controller setup mode.
Standby mode. The energizer has been placed into standby and has stopped
pulsing. Press the standby bu
tt
on to resume normal opera
ti
on.