Page 8
3E4288 Gallagher T10 Reader | Edition 1 | August 2016
Copyright © Gallagher Group Limited
Bezel
Building cable
No. 6 pan head screw
No. 6 pan head screw
4.
Connect the reader tail extending from the facia assembly to the building cable. Connect the
wires for the appropriate reader you wish to interface, either an HBUS Reader or a Cardax IV
Reader, as shown.
Note:
Gallagher PIV readers must be connected as HBUS Readers. Gallagher PIV readers connect
to the Gallagher Controller 6000 High Spec PIV (C305101) only.
An HBUS Reader connects to a Gallagher Controller 6000, Gallagher 4H/8H Module (attached to
a Controller 6000) or a Gallagher HBUS Door Module (connected to a Controller 6000).
A Cardax IV Reader connects to a Gallagher Controller 6000, Gallagher 4R/8R Module (attached
to a Controller 6000), Gallagher GBUS Universal Reader Interface (Gallagher GBUS URI), Gallagher
Controller 3000-8R or 3000-4R, Gallagher Local Bus Universal Reader Interface (Gallagher URI) or
a Gallagher Local Bus Reader I/O Interface.
HBUS Reader connection:
HBUS Reader terminated:
Positive
Red
Negative
Black
HBUS Termination Orange
HBUS A
Green
HBUS B
Brown
CDXIV TX
White
CDXIV RX
Blue
HBUS R
eader
Positive
Red
Negative
Black
HBUS Termination Orange
HBUS A
Green
HBUS B
Brown
CDXIV TX
White
CDXIV RX
Blue
HBUS R
eader
Note:
To terminate an HBUS Reader, connect the
Orange
(HBUS Termination) wire to the
Green
(HBUS A) wire.
Cardax IV Reader connection:
Positive
Red
Negative
Black
HBUS Termination Orange
HBUS A
Green
HBUS B
Brown
CDXIV TX
White
CDXIV RX
Blue
Car
da
x IV R
eader