Introduction

The Gallagher T10 Reader is a smart card proximity reader.  It can be installed as either an entry reader 

or exit reader.  The reader sends information to the Gallagher Controller and acts upon information sent 

from the Gallagher Controller.  The reader itself does not make any access decisions.
The reader is available in four variants.  The card technologies for each variant are shown below.

Reader

Product codes

Supported card technologies

T10 Mifare Reader Black 

 

T10 Mifare Reader White

C300400

 

C300401

Mifare DESFire EV1, Mifare Plus and 

Mifare Classic

T10 PIV Reader Black

 

T10 PIV Reader White

C305400

 

C305401

PIV, PIV-I, Mifare DESFire EV1, Mifare 

Plus and Mifare Classic

The reader can be connected as an HBUS Reader or Cardax IV Reader.  An HBUS Reader uses the HBUS 

communications protocol to communicate with the Gallagher Controller.  A Cardax IV Reader uses the 

Cardax IV Reader communications protocol to communicate with the Gallagher Controller.  

IMPORTANT: HBUS compatibility

 

HBUS communications are supported with sites running Gallagher Command Centre vEL7.00 software 

(or later).

IMPORTANT: PIV readers

 

Gallagher PIV readers connect to the Gallagher Controller 6000 High Spec PIV (C305101) only (referred 

to as the Controller).  Gallagher PIV readers can only be used with sites running Gallagher Command 

Centre vEL7.10 software (or later).  Gallagher PIV readers are connected as HBUS Readers only.

Before you begin

2.1  Shipment contents

Check the shipment contains the following items:

• 

1 x Gallagher T10 Reader facia assembly

• 

1 x Gallagher T10 Reader bezel

• 

1 x M3 Torx Post Security screw

• 

2 x 25 mm No.6 self tapping, pan head, Phillips drive fixing screws

• 

2 x 40 mm No.6 self tapping, pan head, Phillips drive fixing screws

2.2  Power supply

The Gallagher T10 Reader is designed to operate over a supply voltage range of 9 - 16 Vdc 

measured at the reader terminals.  The operating current draw is dependant on the supply 

voltage at the reader.  The power source should be linear or a good quality switched-mode 

power supply.  The performance of the reader may be affected by a low quality, noisy power 

supply.

Содержание C300400

Страница 1: ...0 Reader Edition 1 August 2016 Copyright Gallagher Group Limited Gallagher T10 Reader Installation Note T10 Mifare Reader Black C300400 T10 Mifare Reader White C300401 T10 PIV Reader Black C305400 T10...

Страница 2: ...ess and it should not be relied on as such To the extent permitted by law all express or implied or other representations or warranties in relation to the information are expressly excluded Neither Ga...

Страница 3: ...2016 Copyright Gallagher Group Limited Contents 1 Introduction 4 2 Before you begin 4 3 Distance between readers 7 4 Installation 7 5 LED indications 9 6 Accessories 10 7 Technical specifications 10 8...

Страница 4: ...s protocol to communicate with the Gallagher Controller IMPORTANT HBUS compatibility HBUS communications are supported with sites running Gallagher Command Centre vEL7 00 software or later IMPORTANT P...

Страница 5: ...i e A T or Star topology should not be used between devices Should Star or Home Run wiring be required the HBUS 4H 8H Modules and the HBUS Door Module allow multiple HBUS devices to be individually wi...

Страница 6: ...ELDEN 9842 shielded 2 twisted pair Each 2 x 0 2 mm2 24 AWG 500 m 1640 ft 200 m 650 ft 100 m 330 ft SEC472 4 x 0 2 mm2 Not twisted pairs 24 AWG 400 m 1310 ft 200 m 650 ft 100 m 330 ft SEC4142 4 x 0 4 m...

Страница 7: ...tal surface The recommended mounting height for the reader is 1 1 m 3 6 ft from the floor level to the centre of the reader device However this may vary in some countries and you should check local re...

Страница 8: ...oller 6000 A Cardax IV Reader connects to a Gallagher Controller 6000 Gallagher 4R 8R Module attached to a Controller 6000 Gallagher GBUS Universal Reader Interface Gallagher GBUS URI Gallagher Contro...

Страница 9: ...teps 8 Configure the reader in Command Centre If the reader is connected as an HBUS Reader refer to the topic Configuring HBUS Devices in the Command Centre Configuration Client Online Help If the rea...

Страница 10: ...0 7 Technical specifications Routine maintenance Not applicable for this reader Cleaning This reader should only be cleaned with a clean lint free damp cloth Voltage 9 Vdc 16 Vdc Current Idle 1 Maximu...

Страница 11: ...frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occu...

Страница 12: ...gust 2016 Copyright Gallagher Group Limited 9 Mounting dimensions IMPORTANT This picture is not to scale therefore use the measurements provided 115 mm 4 53 35 mm 1 38 44 mm 1 73 40 mm 1 57 13 mm 1 2...

Отзывы: