English
TROUBLESHOOTING
Problem
Cause
Solu on
B
appears next to the zone
informa on
e.g.
Z1:10A 2.9kV! B
Ba ery power for a zone
is low.
In Example 1, Zone 1 has
no current alarm, but does
have a voltage and low
ba ery alarm.
Replace ba ery
M
appears next to the zone
informa on when I request a
status message.
e.g.
Z6:M
Zone has a mains power
failure (Alarm Systems only)
and is now opera ng on
back-up ba ery.
Check mains power supply
ER21
appears next to the zone
informa on.
e.g.
Z5:ER21
Energizer has lost
communica on with the
zone/s
Check that the zone device
is connected and working
correctly
The registered phones received
a response
REG (mobile number 1)
REG (mobile number 2)
REG FULL, ID (mobile
number 3)
when trying to
send
REG
to register a third
phone to the SMS Energizer
Controller.
Two phones are already
registered to your SMS
Energizer Controller.
You will need to de-register
one of the two phones.
Refer to
Advanced Ac ons
p.
50
.
Both registered phones have
been lost and I need to register
my new phone to the SMS
Energizer Controller.
You need to reset the
SMS Energizer Controller,
by
fi
rst turning the SMS
Energizer Controller OFF.
Then perform an ON/OFF
within one second three
mes un l the LED shows
RED before the normal
start up sequence.
T
appears next to the Energizer
informa on.
e.g.
EN:0A 6.5kV T!
High temperature alarm.
Improve ven la on around
the Enegizer to allow it to
cool.
EN:ERROR
is displayed and
energizer has stopped.
Internal fault or mains
supply out of range.
Return to Service Centre if
error persists.
51
Gallagher 3E3618 i Series Energizer User Manual
Содержание 3E3446 M5800i
Страница 1: ...FENCE ENERGIZER iSERIES Instructions ENG...
Страница 4: ......
Страница 20: ......
Страница 21: ...ENERGIZER REMOTE FAULT FINDER...
Страница 30: ......
Страница 31: ...FENCE MONITOR...
Страница 43: ...SMS ENERGIZER CONTROLLER...
Страница 53: ...ALARM SYSTEM...