Gallagher 3E3618 i Series Energizer User Manual
42
English
Status LED
Status LED will only operate once a er the Energizer has been turned on.
One
fl
ash
Registra on sent to Energizer
Two
fl
ashes
Registra on with Energizer con
fi
rmed
TROUBLESHOOTING
Problem
Causes
Solu on
Fence Monitor zone
does not appear on the
Energizer Controller
Ba eries are
fl
at
Ba eries or ba ery holder are
installed incorrectly
Fence Monitor needs rese ng
There are 2 fence monitors on
the same zone
The fence voltage is less than
500V
The energizer is incorrectly
connected to the fence
Replace ba eries
Install ba eries / ba ery
holder correctly
Remove ba ery holder for 5
minutes to reset the Fence
Monitor
Give each fence zone a unique
number. See p. 8.
Repair fence
Connect your earth system
to the earth terminal (on the
le ), and the fence to the
fence terminal (on the right)
Zone current measures
lower than expected
Poor Fence Monitor earth
Fence installa on
Ba eries are low
Use addi onal earth stakes
Check all power to zone runs
through the Fence Monitor
Replace ba eries
Error 21 is displayed on a
fence zone
Communica on with Fence
Monitor has been lost
Check the Fence Monitor