![Galil DMC-21x3 Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/galil/dmc-21x3/dmc-21x3_user-manual_3275740035.webp)
DMC-21x3 Accessories
Chapter 5 SDM-20240/20242• 33
______________________________________________________________________________
Additional Settings for SDM-20242
Micro Step jumpers (JP1)
Determines whether pulses from the controller are interpreted by the Driver chips as whole, half,
or micro-step increments.
No Jumper = Full step
1
M1 ON only = Half step
M2 ON only = 1/4
th
step
M1 and M2 ON = 1/16
th
step
1
When running in
full step
mode – the current to the motor is 70% of maximum. All micro-step
settings are able to deliver full current
Protection Circuitry and Error LED
The SDM-20242 has short circuit protection circuitry as well as under/over voltage and over
temperature protection. Here is a list of possible reasons for the Error LED to turn on and stop all
motors from operating:
•
If the motor leads are shorted together, or shorted to ground
•
Power is applied to the controller before the driver board
When the LED comes on, the error has to be cleared by issuing MO;SH. If the controller is in
LC*=1 mode, an LC*=0;LC*=1 command is required to clear the error condition.
ELO (Emergency Lock Out)
The Emergency Lock Out jumper (ELO on JP1) is a jumper setting on the SDM-20242 which
configures the driver’s behavior when the abort line goes low. With the jumper absent (default),
the behavior of the motors is subject to the OE command. When the jumper is installed, the
amplifiers will be immediately shut down at a hardware level (bypasses the controller firmware).
When the ELO jumper is installed, the OE command should be set to 1. To recover, issue
MO;SH.
Fault Output from SDM-20242
The fault output jumper allows the user to choose to bring out the amplifier’s error signal to either
the Abort line or Input 7 of the controller. With no jumper – the fault signal is not connected to
the controller at all. If a jumper is placed between the center pin and towards the side that says
7_IN – then input 7 is used. Conversely, if the jumper is placed between the center pin and the
side that says ABORT – the Abort line is jumpered to the fault output.
JP5 FLT
7_IN
ABORT
Содержание DMC-21x3
Страница 10: ...8 Chapter 1 Overview DMC 21x3 Accessories THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 14: ...12 Chapter 2 SR 19900 DMC 21x3 Accessories THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 20: ...18 Chapter 3 ICM 20100 DMC 21x3 Accessories THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 36: ...34 Chapter 5 SDM 20240 20242 DMC 21x3 Accessories THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 46: ...44 Chapter 7 AMP 20440 20420 DMC 21x3 Accessories Abort Input Options See Appendix A...
Страница 60: ...58 Chapter 9 AMP 20540 20520 DMC 21x3 Accessories Abort Input Options See Appendix A...
Страница 74: ...72 Chapter 11 SDM 20640 20620 DMC 21x3 Accessories THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 76: ...74 Chapter 12 PCM 20900 DMC 21x3 Accessories THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 82: ...80 Chapter 13 DB 28040 DMC 21x3 Accessories THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 92: ...90 Chapter 14 DB 28104 DMC 21x3 Accessories THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 98: ...96 Chapter 15 Cables for AMP 20xxx DMC 21x3 Accessories THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 102: ...100 Appendix A Abort Input Options DMC 21x3 Accessories THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 104: ...102 Appendix B Mating D Shells DMC 21x3 Accessories THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 105: ...DMC 21x3 Accessories Appendix C Command Reference 103 Appendix C Command Reference...