Step D.
Connect the Motor
Once the parameters have been set, connect the analog motor command signal (ACMD) to the
amplifier input.
To test the polarity of the feedback, command a move with the instruction:
PR 1000 <CR> Position relative 1000 counts
BGA <CR>
Begin motion on A axis
When the polarity of the feedback is wrong, the motor will attempt to run away. The
controller should disable the motor when the position error exceeds 2000 counts. If the motor
runs away, the polarity of the loop must be inverted.
Inverting the Loop Polarity
When the polarity of the feedback is incorrect, the user must invert the loop polarity and this may be
accomplished by several methods. If you are driving a brush-type DC motor, the simplest way is to
invert the two motor wires (typically red and black). For example, switch the M1 and M2 connections
going from your amplifier to the motor. When driving a brushless motor, the polarity reversal may be
done with the encoder. If you are using a single-ended encoder, interchange the signal CHA and CHB.
If, on the other hand, you are using a differential encoder, interchange only CHA+ and CHA-. The
loop polarity and encoder polarity can also be affected through software with the MT, and CE
commands. For more details on the MT command or the CE command, see the Command Reference
section.
Sometimes the feedback polarity is correct (the motor does not attempt to run away) but the direction
of motion is reversed with respect to the commanded motion. If this is the case, reverse the motor
leads AND the encoder signals.
If the motor moves in the required direction but stops short of the target, it is most likely due to
insufficient torque output from the motor command signal ACMD. This can be alleviated by reducing
system friction on the motors. The instruction:
TTA <return> Tell torque on A
reports the level of the output signal. It will show a non-zero value that is below the friction level.
Once you have established that you have closed the loop with the correct polarity, you can move on to
the compensation phase (servo system tuning) to adjust the PID filter parameters, KP, KD and KI. It is
necessary to accurately tune your servo system to ensure fidelity of position and minimize motion
oscillation as described in the next section.
DMC-2X00
Chapter 2 Getting Started
y
25
Содержание DMC-2010
Страница 18: ...THIS PAGE LEFT BLANK INTENTIONALLY 8 Chapter 1 Overview DMC 2X00...
Страница 48: ...THIS PAGE LEFT BLANK INTENTIONALLY 38 Chapter 2 Getting Started DMC 2X00...
Страница 78: ...THIS PAGE LEFT BLANK INTENTIONALLY 68 Chapter 5 Command Basics DMC 2X00...
Страница 180: ...THIS PAGE LEFT BLANK INTENTIONALLY 170 Chapter 7 Application Programming DMC 2X00...
Страница 215: ...Dimensions for DMC 2x00 DMC 2X00 Appendices y 205...