A2 – SCB-48306/48316
Description
The SCB-48306 and the SCB-48316 Signal Conditioning Board interface to up to 6 thermocouples. The
SCB-483x6 boards are designed to work with the RIO-4712x. The SCB-48316 provides thermocouple
terminal connectors for the 6 thermocouple inputs, the SCB-48306 provides screw terminals inputs for the 6
thermocouple inputs. Both SCB boards provide screw terminal connections for Analog inputs 6 and 7
(AI6:7), all 8 analog outputs (AO0:7) and two GND terminals.
The SCB-48306 can plug directly into the Analog 26-pin high-density D-sub connector and will use Analog
inputs 0-5 on the RIO for the 6 thermocouple inputs. (TC[0:5] = AI[0:5]).
1
It is oriented vertically from the
RIO connector as shown in Figure 14. Other mounting options are available upon request.
By default the SCB-483x6 will be setup for type K thermocouple inputs. Types E, J and T are also available.
The thermocouples interfacing to the SCB-483x6 must have an Ungrounded or Exposed Junction (aka
Floating Junction); contact Galil if Grounded Junction thermocouples are required.
Figure 14: SCB-48316
Figure 15: SCB-48306
1
Analog inputs 0-5 will not be available for general use analog inputs when the SCB-483x6 is connected to the RIO.