OUTC jumpers
The OUTC jumpers can be used when an external power supply is not desired for digital outputs 8-15.
These low power outputs can use the in5V from the RIO instead of an external supply. To do this,
place a jumper on the pins labeled OUTC as shown in Figure 4.10.
1. These jumpers DO NOT supply power to high power digital outputs, an external supply is
required for those outputs.
2. With the RIO-472xx, the OUTC jumpers are only available when LSRC or LSNK options are ordered
from the factory.
3. OUTC jumpers are not available on the RIO-47142 or RIO-47300 (all high power outputs).
PWM Outputs
With firmware revisions Rev D and newer, Digital Outputs 14 and 15 can be setup independently as PWM
outputs using the DY, FQ and PM commands. The standard optoisolated outputs found on the RIO-47xxx
will have a limited bandwidth (50Hz) that will not allow the full range of frequency and duty cycle
available from the DY, FQ and PM commands. The RIO can be ordered with a –PWM option that will
bypass the optoisolated outputs and provide buffered outputs for DO[15:14]. See the -PWM section in
the Appendix for more information.
Digital Inputs
The RIO-47xxx has 16-24 optoisolated inputs (depending on model). These inputs can be read individually
using the function
@IN[x]
where x specifies the input number (0 thru 23). These inputs are
uncommitted and can allow the user to create conditional statements related to events external to the
PLC.
This can be accomplished by connecting a voltage in the range of +5V to +24V into INCOM of the input
circuitry from a separate power supply.
Chapter 4 I/O ▫ 45 RIO-47xxx Rev 1.0r
Figure 4.9: 25mA Sourcing wiring diagram for Bank 2, DO[23:16]
Figure 4.10: OUTC jumpers for RIO