Galene GS Series Скачать руководство пользователя страница 13

OPERATION AND MAINTENANCE MANUAL 
WATER FILTRATION SYSTEM    

12 

o

Turn valves on item #1 to the “SERVICE” position as illustrated in Figure 5.

Note: Your system is equipped with a bypass valve for the Softener filter
(A).  In  case  required,  push  nob  firmly  on  Item  #4-R/  #5-L  (Right  or  Left
installation) moving the piston from right to left. At this point your filter
will  be  bypassed  and  no  longer  operate.  If  purchased  an  installation  kit,
an  additional  bypass  is  included  in  item  #1.  Position  the  valves  in
“BYPASS” as illustrated in Figure 5 to circumvent the whole system. This
will  be  used  in  case  of  a  leak,  or  just  regular  service,  assuring  no  water
flows through your unit.

Backwashing Softener Filter vessel

o

Backwash  and  regeneration  cycle  will  be  done  automatically  based  on  a
preset time uploaded in factory. If required, call GALENE to change setting
on the timer.

Note: Do not attempt to change time on your own, as this may result in
the system malfunction.

Cartridge Filter

o

Replace cartridge filter every 3 months

o

Prior to replacing filter, make sure to position valves on item #1 on “BYPASS
position as illustrated in Figure 5.

o

Press red button on top of cartridge filter to release pressure.

o

Using  the  special  tool  provided,  open  the  blue  filter  sump.  Make  sure  to
have a recipient on the bottom, to prevent water from spilling on floor.

o

Replace cartridge in the sump, using a new GALENE cartridge. For best seal,
replace  o-rings  on  sump  and  apply  silicon  ointment  (such  as  Dupont
Molykote, 111 Compound).

o

Close  the  blue  filter  sump  using  the  special  tool.  Do  not  over  tight  the
sump.

o

Turn valves on item #1 to the “SERVICE” position as illustrated in Figure 5
and resume normal operation.

Chlorine line wash

o

It  is  recommended  to  introduce  city  water  into  the  house  every  30  –  60
days, for pipe and device disinfection with chlorinated water.

Содержание GS Series

Страница 1: ...elcome to the GALENE family Your new GALENE whole house GS system was expertly engineered to reduce water hardness throughout your entire home Start enjoying your fresh clear water every day Whole Hou...

Страница 2: ...2 1 PRODUCT DESCRIPTION 2 2 PROCESS DESCRIPTION 2 Stage I 2 Stage II 2 Stage III Optional 2 II BOX CONTENT 3 III INSTALATION PROCEDURE 5 1 SYSTEM LAYOUT 5 2 SITE PREPARATION 6 3 INSTALLATION 7 IV OPER...

Страница 3: ...Description Model GS1 GS2 GS3 Capacity 1 3 Bath 4 6 Bath Estate 2 Process Description Stage I 10 micron cartridge GAC filtration Stage II Media Ion Exchange softener based filter with electric actuate...

Страница 4: ...OPERATION AND MAINTENANCE MANUAL WATER FILTRATION SYSTEM 3 II BOX CONTENT Open the boxes delivered and make sure you have all the pieces The items should include...

Страница 5: ...OPERATION AND MAINTENANCE MANUAL WATER FILTRATION SYSTEM 4...

Страница 6: ...OPERATION AND MAINTENANCE MANUAL WATER FILTRATION SYSTEM 5 III INSTALATION PROCEDURE 1 System Layout Figure 1 System Layout based on main line side...

Страница 7: ...roper sequence of the filters will affect performance and may damage the unit 2 System is designed to operate between 20 psi 80 psi DO NOT exceed 100 psi in any case 3 System is designed to operate on...

Страница 8: ...nstallation With GALENE Installation Kit o Take out all the pre assembled PVC lines included in the installation kit and make sure you identify all the items from 1 to 6 Figure 2 Component layout Righ...

Страница 9: ...will not have a good seal and will create leakage Make sure you do not overtight the union with a wrench This can break the union and will require to replace the piece For best results and to minimiz...

Страница 10: ...eed to be routed to the drain This will be the water line that will discharge the dirty water when the Softener Filter A is being cleaned backwashed automatically Note Drain line may create flooding i...

Страница 11: ...uded as shown in the Figure 4 below Figure 4 Grounding clamps WARNING Electric Shock Hazard if not installing the grounding clamps with the 4 copper wire Connect the electric transformer on the valve...

Страница 12: ...s or rupture o Position valves on item 1 to the BACKWASH position as illustrated in Figure 5 below F igur e 5 Byp ass Valv es o Assure you have salt in brine tank o Press the backwash button on the el...

Страница 13: ...GALENE to change setting on the timer Note Do not attempt to change time on your own as this may result in the system malfunction Cartridge Filter o Replace cartridge filter every 3 months o Prior to...

Страница 14: ...ce UV light In case your system is equipped with one Figure 6 UV Lamp o Replace UV light every year or when red light on ballast blinks It is recommended to use an experienced technician to do the rep...

Страница 15: ...is designed and tested for use with genuine GALENE parts including replacement filters and all hardware Use of parts from other manufacturers may result in loss of contaminant reduction performance s...

Страница 16: ...esulting flow of water will not cause damage to the area in which it is installed GALENE will not recognize claims or make allowances for replacement of materials or correction of GALENE S error unles...

Страница 17: ...part s to the owner b All costs necessary or incidental in removing the defective water filter or component part s and installing a new water filter or component part s c Any material required to comp...

Отзывы: