4.4 Wiring the Solenoids - 3 wires
ln the DC controllers connect the valves to the cables emerging from
the controller according to the illustration and explanation below.
Labeled cables (1) emerge from the controller. The end of each cable
is protected by a cover that must be removed prior to connecting the
cable. The cables are specifically designed to connect to Galcon DC
type irrigation valves and solenoids (3).
NOTE- The controller and its connections are waterproof. To
safeguard the waterproof characteristics, compliance with the
following is essential:
•
Do not remove protective covers from cables that are not
connected to valves. Exposed cable ends can short-circuit
with each other, with conducting bodies and in water.
•
Connect the cables to the valves (3) using the special waterproof
connectors (2) supplied with the product. See illustration.
1. Cut away the covering from the controller cable (1) near the end of
the cable and expose the cable leads from the black insulating
outer sleeve. The solenoid cables
have three wires: white, red and black. Do not expose the three
wires from their colored insulation.
2. Connect the leads to waterproof connector (2)